My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2727 COLBY AVE EIGHT BALL CAFE 2018-09-07
>
Address Records
>
COLBY AVE
>
2727
>
EIGHT BALL CAFE
>
2727 COLBY AVE EIGHT BALL CAFE 2018-09-07
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/7/2018 10:53:31 AM
Creation date
9/7/2018 10:53:21 AM
Metadata
Fields
Template:
Address Document
Street Name
COLBY AVE
Street Number
2727
Tenant Name
EIGHT BALL CAFE
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
96
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
4 <br /> 1R <br /> 13. When splashguards (partitions and/or walls) are provided on both sides of a handwash sink the <br /> distance between the splashguards must be at least 18 inches apart (shoulder width) to allow <br /> proper accessto the handwash sink. <br /> 14. Water heaters must be of sufficient size to provide hot water to dishwasher and/or scullery sinks <br /> and at the same time provide hot water to all handwash sinks. <br /> 15. Hot water must be available to all handwash sinks within 15 seconds. The hot water for the facility <br /> must not be used, at any plumbing fixture, for a minimum of 6 hours prior to the preoperational <br /> inspection. This is required so that proper testing of the 15-second time requirement for hot water <br /> availability can be completed. <br /> 16.An under bar handwash sink is indicated at the bar. Under bar(or counter) handwash sinks are not <br /> acceptable. The handwash sink must be installed in a manner that promotes proper accessibility to <br /> the handwash sink basin and faucets. <br /> 17.All handwash sinks basins must be at least 10" long by 10"wide and 5" deep. Ensure that all <br /> handwash sink basins are at least 10"x10"x5". <br /> 18.Al! food service equipment, both new and used, must be listed by the National Sanitation . ..; <br /> Foundation (NSF) or equivalent for its intended use. Used and new refrigeration must be capable of <br /> holding food at temperature of 41°F or below. <br /> 19. Used equipment is subject to onsite inspection to determine acceptability for use in the proposed <br /> food service establishment. Used equipment must be clean, in proper operating condition, and in <br /> good repair. Used refrigeration must be capable of holding at a temperature of 41°F or below. <br /> 20.All food service equipment must be listed by the National Sanitation Foundation (NSF) or equivalent <br /> for its intended use. The Perlick glass cooler, model #8365 AUL, and the Auto-Chlor glass washer, <br /> model #FT-AF-3, were not found in the current NSF or equivalent listings. This equipment must be <br /> replaced with NSF or equivalent listed equipment or documentation must be submitted which <br /> demonstrates NSF equivalency. Manufacturer names and model numbers for replacement <br /> equipment or equipment documentation must be submitted prior to the request for a preoperational <br /> inspection. Originally submitted manufacturer names and model numbers should be rechecked to <br /> assure the information submitted is accurate. Please note that subsidiary manufacturers are often <br /> not found in the NSF and equivalent listings. The manufacturer name should be verified and submit <br /> the parent company name if one is found. <br /> 21. No manufacturer name or model number was submitted for the griddle or the convection oven. The <br /> manufacturer name and model number for this equipment must be submitted prior to the request for <br /> a preoperational inspection. <br /> 22. Extra wall protection is required on walls behind all sinks, including restroom handwash sinks, and <br /> food preparation counters and tables. Sinks in corners must also have wall protection on the side <br /> walls. A 16-inch high backsplash of plastic laminate, fiberglass-reinforced plastic or equal is <br /> acceptable. A backsplash higher than 16 inches is required on the wall behind counter top <br /> equipment taller than 16 inches. Floor to ceiling protection is required on the wall behind <br /> dishwashers. Wall protection behind mop sinks must cover the entire splash zone. Plastic coated <br /> hardboard is not acceptable. <br /> 23.All floors in the kitchen, food preparation, food service, food storage, and dishwashing areas must <br /> be surfaced with a durable, nonabsorbent, easily cleanable material. Expansion joints, seams, saw <br /> cuts and the like in concrete floors in all areas, including customer seating areas, must be filled and <br /> sealed so as to provide a smooth and cleanable surface. <br /> 24. The ceiling above the food preparation areas must be non-perforated, nonabsorbent, smooth and <br /> easily cleanable. <br /> 25. Cabinet shelving must be nonabsorbent, smooth and easily cleanable. (Self stick vinyl or other type <br /> surfaces are not acceptable) <br /> 26.All light fixtures in food preparation and storage areas must be provided with covers and <br /> shatterproof bulbs. Hot hold unit heat lamps must be provided with shatterproof bulbs. <br /> 27. Plumbing must meet state and local codes. 7--, <br /> / 'N <br /> • r <br />
The URL can be used to link to this page
Your browser does not support the video tag.