Laserfiche WebLink
Lighting, Motor, and Tr sformer Permit Document •,hecklist LTG-CHK <br /> 2012 Washington State Energy Code Compliance Forms for ommercial Buildings including R2&R3 over 3 stories and all R1 Revised Jan 2014 <br /> Project Address CHOUX CHOUX BAKERY Date 5/6/2015 <br /> The following information is necessary to check a permit application for compliance with the lighting,motor,and transformer requirements in the <br /> Washington State Energy Code,Commercial Provisions. <br /> Applicability Location in Building Department <br /> (yes,no,na) Code Section Component Compliance information required in permit documents Documents Notes <br /> LIGHTING CONTROLS(Section C405.2) <br /> Indicate on plans the manual control type&locations served; <br /> C405.2.1.1 Manual interior <br /> Yea Indicate of plans the 50%lighting load reduction method <br /> C405.2.1.2 lighting controls <br /> provided or identify exception taken <br /> Indicate lighting system automatic shut-off capability-identify <br /> lighting zone areas served on plans; <br /> Automatic time <br /> Indicate locations of override switches on plans and the areas <br /> Yes C405.2.2.1 switch controls and <br /> served,include area sq.ft.; <br /> override switching <br /> Indicate locations where automatic shutoff is provided by other <br /> methods(occupancy sensor,daylight controls,etc) <br /> Yes C405.2.2.2 Occupancy sensors Indicate on plans the locations served by occupancy sensors <br /> Daylight zones- Indicate vertical fenestration primary and secondary daylight <br /> Yes C405.2.2.3 Vertical fenestration zone areas on plans,include sq.ft.; <br /> and skylights Indicate skylight daylight zone areas on plans,include sq.ft. <br /> Indicate on plans the locations served by daylight zone <br /> Daylight zone controls; <br /> Yes C405.2.2.3.2 <br /> controls Indicate in plans the lighting load reduction(dimming)method- <br /> stepped or continuous dimming <br /> Specific application <br /> Indicate on plans the locations served by specific application <br /> Yes C405.2.3 lighting controls- <br /> General lighting controls <br /> Indicate lighting control method for display and accent lighting, <br /> and display case lighting; <br /> C405.2.3- Display and accent <br /> Yes <br /> Items 1&2 lighting Indicate these fixtures are controlled independently from both <br /> general area lighting and other lighting applications within the <br /> same space <br /> Provide a lighting control device at each guest room entry for <br /> C405.2.3- Hotel/motel guest <br /> all permanently installed fixtures in guest room; <br /> NA Item 3 rooms <br /> Indicated whether lighting control is manual or automatic <br /> C405.2.3- Supplemental task Provide automatic shut-off vacancy controls for supplemental <br /> Yes <br /> Item 4 lighting task lighting,including under-shelf or under-cabinet lighting <br /> Identify eligible non-visual applications and method of lighting <br /> control; <br /> C405.2.3- Lighting for non- <br /> NA <br /> Item 5 visual applications Indicate these fixtures are controlled independently from both <br /> general area lighting and other lighting applications within the <br /> same space <br /> Indicate lighting control method for lighting equipment for sale <br /> Lighting equipment or demonstration; <br /> C405.2.3- <br /> Yes for sale or Indicate these fixtures are controlled independently from both <br /> Item 6 demonstration general area lighting and other lighting applications within the <br /> same space <br /> If egress lighting power density is greater than 0.05W/ft2, <br /> indicate method of automatic shut-off during unoccupied <br /> C405.2.3- Means of egress <br /> Yes periods; <br /> Item 7 lighting <br /> Identify on plans the egress fixtures that function as both <br /> normal and emergency means of egress illumination <br /> Provide vacancy device or timer to turn off fixtures within 15 <br /> C405.10 Cooler and freezer <br /> Yes minutes of unoccupancy for cooler and freezer lighting fixtures <br /> C405.11 lighting with lamp efficacy less than 40 lumens per watt <br /> Exterior lighting Indicate on exterior lighting plans the automatic lighting control <br /> NA C405.2.4 controls method and locations served <br /> Exterior building Provide motion sensor controls for building grounds fixtures <br /> NA C405.6.1 grounds lighting rated at greater than 100 watts with lamp efficacy less than 60 <br /> controls lumens,or identify exception taken <br /> Identify applicable commissioning documentation requirements <br /> per Section C408 or eligibility for exception; <br /> Provide written procedures for functional testing of all <br /> Lighting system <br /> Yea C408.3 automatic controls and describe the expected system <br /> functional testing <br /> response; <br /> Identify in construction documents the party responsible for <br /> functional testing of automatic lighting controls <br /> a <br /> INTERIOR LIGHTING POWER&EFFICACY(Sections C405.5,C405.10,C405.11) ( U <br />