Laserfiche WebLink
Interior Lighting Sum lry - Space-By-Space LTG-INT-SPACE <br /> 2012 Washington State Energy Code Compliance Forms for Commercial Buildings including R2&R3 over 3 stories an.a I RI Revised Jan 2014 <br /> Project Address CHOUX CHOUX BAKERY Date 5/6/2015 <br /> Lighting Alterations,Renovations &Building Additions For Building Department Use <br /> 0 Less than 60% 0 60%or more 0 Stand alone 0 Addition <br /> Notes: <br /> a.Lighting fixtures in a building addition may comply as a stand alone project,or they may be <br /> combined with the overall existing bldg lighting to demonstrate compliance.Refer to C101.4.3. <br /> b.For retrofits and building additions,provide Space Types and gross interior areas in the <br /> Maximum Allowed Lighting table.If a builidng addition will comply as combined with the overall <br /> existing builidng,include all applicable existing Space Types and gross interior areas. <br /> c.Document new fixtures and all existing to remain fixtures in the Proposed Lighting table. <br /> d.If less than 60%of existing fixtures will be replaced,provide total existing lighting wattage <br /> (prior to retrofit)in the space provided in the Maximum Allowed Lighting table. <br /> Maximum Allowed Lighting Wattage <br /> Location(plan#, Allowed Gross Intenor Watts Allowed <br /> room#) Space Type* Watts per ft2 Area in ft2 (watts/ft2 x area) <br /> Food Prep Area Food preparation 0.99 470 465 <br /> Sales Area Sales area 1.68 627 1053 <br /> Attdum"*_> Enter Height: <br /> Existing Lighting Enter Exist.Watts <br /> Retail Display Allowance from LTG-INT-DISPLAY 516 <br /> * Select Table C405.5.2(2)category from drop down menu. Area Allowed Watts <br /> ** For atriums,indicate height.Allowed wattage for first 40 feet is 0.03 W/ft.ht., Total 1097 2035 <br /> above 40 feet is 0.02 W/ft.ht. <br /> Proposed Lighting Wattage <br /> Location(plan#, Number of Watts/ Watts <br /> room#) Fixture Description*** Fixtures Fixture Proposed <br /> Food Prep Area A 11 84 924 <br /> Sales Area C 2 75 150 <br /> Sales Area D 3 120 360 <br /> Retail Display Lightting from i.TG-INT.DISPLAY 516 <br /> Total Proposed Watts may not exceed Total Allowed Watts for Interior Lighting Total Proposed Watt 1950 <br /> ***Include existing to remain lighting fixtures and exempt lighting equipment per notes below. <br /> Notes: <br /> 1.Include ALL proposed lighting fixtures. <br /> 2.For proposed Fixture Description,indicate fixture type,lamp type(e.g. T-8),number of lamps in the fixture,and ballast type(if included).For <br /> track lighting,list the length of the track(in feet)in addition to the fixture,lamp,and ballast information. <br /> 3.For proposed Watts/Fixture,use manufacturer's fisted maximum input wattage of the fixture(not simply the lamp wattage)and other criteria <br /> as specified in Section C405.5.1.For line voltage track lighting,list the greater of actual luminaire wattage or length of track multiplied by 50, <br /> or as applicable,the wattage of current limiting devices of the transformer.For low voltage track lighting list the transformer rated wattage. <br /> 4.For lighting equipment eligible for exemption per C405.5.1,note exception number and leave Watts/Fixture blank <br /> 5.Document existing to remain fixtures in Proposed Lighting table in the same manner as new fixtures.Identify as existing in fixture description. <br /> 6.If#NA appears in Retail Display cells,information on LTG-INT-DISPLAY is incomplete. <br /> Interior Lighting Power Allowance COMPLIES <br />