• <br /> GENERAL NOTES T <br /> THIS ELECTRICAL PLAN IS THE ARCHITECT'S SUGGESTED LAYOUT. THE <br /> ELECTRICAL CONTRACT IS ON A DESIGN-BUILD BASIS. ELECTRICAL /, ,A , <br /> CONTRACTOR'S DESIGN SHALL BE APPROVED BY THE OWNER AND SHALL IFAtial r �, A ' <br /> CONFORM TO THE APPLICABLE ELECTRIC CODE REGARDLESS OF WHAT IS I vl metvio <br /> om <br /> SHOWN ON THIS DRAWING. i �� 0 '} A' , ygy;'�s <br /> METER CENTER LOCATIONS SHALL BE COORDINATED WITH THE ARCHITECT. r- 0 -i 1 3 <br /> il <br /> HIGHEST OPERABLE PART OF ENVIRONMENTAL AND OTHER CONTROLS SHALL �'IligyaniNoi?', ;° <br /> MOUNTED NOT LESS THAN 36 INCHES ABOVE FLOOR. ELECTRICAL AND Patio 1,,:olikamt.,..: :g4,.:,„:,,s6,..:r t a 44 'k l <br /> COMMUNICATIONS SYSTEMS ON WALLS SHALL BE MOUNTED A MIN. OF 15 <br /> INCHES ABOVE FLOOR. 0.:,18.44.493 g.. " A <br /> OUTLETS, SWITCHES, TELEPHONE AND TV, ETC. BOXES IN PARTY WALLS OF 2 S s n ,, ° ,h <br /> ONE UNIT SHALL BE IN DIFFERENT STUD SPACES THAN THOSE IN u U 111,1000011066411 <br /> rwC rltt' iN d. t ,`e 2JO s <br /> THE ADJACENT UNIT. NO TWO ADJACENT UNITS SHALL HAVE SUCH BOXES I �®' I I Y kfand,ll , ;' 6 as <br /> IN THE SAME STUD SPACE. BOXES SHALL BE SEPARATED HORIZONTALLY • WH <br /> ,�, ` �. ky>�v` `• A®I I,r.,-ID �e , r < <br /> a',k �"et+ ,e <br /> BY 24 . <br /> TV 1000W ELEC /' I 1500W ELEC II <br /> INDIVIDUAL ELECTRICAL OUTLET BOXES SHALL BE OF STEEL OR OTHER 1 CEILING HEATER / i CEILING HEATER TOP HALF <br /> APPROVED MATERIAL AND SHALL NOT BE GREATER THAN 16 SQUARE / I ( /. <br /> INCHES IN AREA. j <br /> -•----_ <br /> / <br /> ' I �� ' �, `/ ' I 5052 REGISTERED ' <br /> THE WATER HEATERS SHALL BE STRAPPED PER IRC P2801.7 AT A POINT CFP / t ju...6.8....ARCHITECT <br /> WITHIN THE UPPER 1/3 AND THE LOWER 1/3 OF ITS VERTICAL DIMENSION. / gie <br /> THE LOWER STRAP SHALL BE NOT LESS THAN 4" ABOVE ANY CONTROLS. i Master I qt j' <br /> WATER HEATERS SHALL BE PROVIDED WITH A PRESSURE/TEMPERATURE / \ Living ( I ROBERT E. WEIBLE <br /> RELIEF VALVE THAT IS CONNECTED TO A DRAIN LINE. THE DRAIN LINE Bedroom / i , , , 1 STATE OF WASHINGTON <br /> SHALL BE DIRECTED TOWARD THE GROUND AND TERMINATE AT A POINT NO /LESS THAN 6" AND NO MORE THAN 24" ABOVE THE GROUND. I1 // C ; TO �./ I\ // <br /> SMOKE DETECTORS SHALL BE EQUIPPED WITH A BATTERY BACK-UP, SHALL I • i C ( ' <br /> EMIT A SIGNAL WHEN BATTERIES ARE LOW, SHALL BE PERMANENTLY HARD / <br /> TEL00 FIREPLACE ail \ <br /> WIRED AND WITHOUT A DISCONNECTING SWITCH OTHER THAN THOSE - �F= I , \ _T_ I / T T <br /> REQUIRED FOR OVERCURRENT PROTECTION, AND SHALL SOUND AN ALARM +)r1 ® �\ ®` . s s �` ' STACK \ ' <br /> AUDIBLE IN ALL SLEEPING AREAS OF THE DWELLING IN WHICH THEY ARE ' •\I SD 250W WALL I THERMOSTAT \ / <br /> LOCATED. M _ �' UNIT HEATER \"\ & SWITCH — — I j <br /> - Bath . I ; I :: j - _ <br /> ENERGY NOTES / - r, ..3 ,� i <br /> SEE ENERGY NOTES ON SHEET Al & D5. I VTR.--0-110 / / h. ' '"�y .. <br /> I <br /> a <br /> \ ( 1I''i i- - v <br /> WATER HEATER SHALL BE FUELED BY GAS AND HAVE A MINIMUM EF OF I \\+ �-- i j_i:.1 WE ► �" I I Z <br /> 0.82. _, -0- ! 6:di_)•, <br /> t I _ �/ ( L` I • <br /> HOT AND COLD WATER HEATER PIPES IN UNCONDITIONED SPACES SHALL BE LA _A 0 • rS i I �' 1 ! I W <br /> INSULATED WITH R-3 INSULATION WHICH HAS A FLAME SPREAD OF 25 OR �--�TQ I • O P�� \ \. ` <br /> �• ► Ctl11 E:: <br /> LESS. \ ,i DRIER14481..n 1i \ Fy!. ` \1 L <br /> o .� WH 1 .•I•., t i \ I•.. •• \ ELEC-1 <br /> VENTILATION NOTES I .1 ,c - + ' ( PANEL 1 • <br /> _ �, , ISI"; Ki hen—__V ° i 1_.,::.:.: 1 • <br /> 1 VTIR+4 ..::I. J �i 1 '. \ <br /> VENTILATION: SEE NOTES ON COVER SHEET. % \ I DW I r1 r+ <br /> _ WASHER L'y 1250W 1-:',.)t.. <br /> — <br /> 1 I I .'.'.'.1,'1 —-- J I f / ELEC 1.'!sp'. •�'N �I - c) <br /> ALL EXHAUST DUCTS SHALL BE RIGID METAL, AND SHALL BE FITTED WITH A I / Bat ` Imo^ I I I':1 1 CEILING I N o . <br /> TIGHT FITTING BACKDRAFT DAMPER CAPABLE OF CLOSING WHEN THE FAN IS �' ,; HEATER <br /> NOT IN USE. C� ! I \ • <br /> AT \ \ <br /> mal , �. i ` v <br /> .CEILING '\ \ z Q <br /> DUCTS IN UNHEATED SPACES INCLUDING ATTICS SHALL BE INSULATED TO A it \• <br /> \ C I <br /> I ' \ <br /> MINIMUM OF R-8< �"' • via <br /> TOP FLOOR EXHAUST FANS SHALL VENT THROUGH ATTIC. ELEC t j I I \ \.\ /•_. Al /• . , <br /> PANEL I 6'-6'' 1 I ' . \ E ' I i ( o m <br /> DRYER EXHAUST DUCT SHALL BE 4" RIGID METAL WITH A 4" OPENING ON I \! ; �� I / z I \ , "- <br /> THE EXHAUST HOOD. THE DRYERS DUCTS SHALL BE GALVANIZED STEEL OR SD / TECH r / Garage , .' I N <br /> ALUMINUM, MINIMUM 0.016" THICK. THE DRYERS SHALL BE GENERAL I I • Tech PORT I I I i • I / \ 1 a <br /> ELECTRIC. DRYERS SHALL BE INSTALLED ACCORDING TO MANUFACTURER'S Bedroom 1 . / , D i : � , ! AT CEILING: PREWIRE 450W <br /> INSTALLATION INSTRUCTIONS ON SITE. / Tv- j Area I I �� I I ! LOW VOLTAGE WIRE FOR j ELEC ./ <br /> I ' I .•. .•.•. i , GARAGE DOOR OPENER .BASEBOARD f•' L. <br /> WINDOW OUTDOOR AIR INLETS SHALL PROVIDE THE EQUIVALENT OF 4 SQ. ( . Dining PENDANT I F I I AND ELECTRIC EYES i -.NCl) <br /> IN. OF NET FREE AREA. TOP .P .... r • ( i VERIFY LOCATION WITH ' <br /> 1 >< TECH I OPENER INSTALLATION \ �) <br /> \HALF PORT .;.:•:.:.:...:.... ( ! Z <br /> • 500W ELEC Q <br /> al CEILING HEATER V i I I .:....(.:................T ' BELL - -- J a N • <br /> Vim ` `n (�..'...... . Usi a. c <br /> 750W ELEC 1500W ELEC I WI / <br /> h CEILING HEATER Q i----' CEILING HEATER <br /> WIEI HOSEI •-� <br /> BIBL311 El .,. . <br /> s s _, Z rx- . <br /> ELECTRICAL LEGENDT° <br /> - PHOTOCELL p (ii ii) - ° <br /> = Q <br /> W � > <br /> & DUPLEX RECEPTACLE OUTLET DIRECTIONAL CEILING J ' <br /> 4 MOUNTED LIGHT LLI <br /> DUPLEX RECEPTACLE OUTLET <br /> SPLIT WIRED (SWITCH TOP HALF) UPPER LEVEL MAIN LEVEL <br /> -ep!-- CEILING MOUNTED LIGHT <br /> Mo DUPLEX RECEPTACLE OUTLET UNIT F UTILITY PLAN UNIT F UTILITY PLAN LOWER LEVEL o <br /> MICROWAVE RECESSED CEILING E 12/D1 1/4"--1'-0" <br /> 1/4"=1' 0" 1/4"=V-O" a ti <br /> IiNIT UTILITY PLAN °� �' <br /> O SINGLE RECEPTACLE OUTLET / <br /> 1/4"=1'-0" _ <br /> 208v (R: RANGE, D: DRYER) • <br /> WALL MOUNTED LIGHT <br /> Q JUNCTION BOX <br /> I. DOUBLE TUBE FLUORESCENT <br /> A TECH PORT CEILING MOUNTED LIGHT mlima <br /> TELT TELEPHONE JACK V CEILING MOUNTED TRACK LIGHT 4 <br /> O <br /> TV TELEVISION JACK iirc,g HEAT LAMP, EXHAUST FAN E > • <br /> $ SINGLE POLE SWITCH COMBINATION RECESSED CEILING �' <br /> FIXTURE - 250W LAMP, 50 CFM 0 <br /> $ <br /> s THREE WAY SWITCH MIN., 3 SONES, 4" ROUND DUCT. <br /> SEE 15/D1 <br /> E <br /> DIMS DIMMER SWITCH g'' g2 2" ,2 BEARING WALL - SEE NOTES cl)> c 0 <br /> THIS SHEET REGARDING BOXES W Q U <br /> $T TIMER SWITCH AND FIRE-RATED WALLS <br /> RECESSED CEILING EXHAUST FAN 1 r' r' I METER CENTER CO CD C (I) <br /> 50 CFM MIN, 3 SONES MAX, a E N 0 <br /> 4" ROUND DUCT. SEE 15/D1 I I ELECTRICAL PANEL 0 �6 <br /> BBHI ELECTRIC BASEBOARD _s = 5 <br /> L®•J1 MICROWAVE ORANE HOOD immlCOMBINA ION,V10EN0 CFM, 3 SONES HEATER <br /> ?r L 0 <br /> SMOOTH DUCT. O THERMOSTAT � Z ' <br /> 'H� RECESSED HEAT LAMP - ;`, SMOKE DETECTOR w 0 > <br /> - NUTONE 9410H, 250W LAMP WITH BATTERY BACKUP <br /> W c <br /> CEILING FIXTURE. SEE 12/D1Ah }� 0 <br /> %le CARBON MONOXIDE ■.,� 0) <br /> II PHOTOCELL SAFETY SENSOR ALARM/SMOKE DETECTOR C <br /> O AUDIBLE SPRINKLER <br /> TECH PANEL SFA FLOW ALARM O Q. <br /> i®! RECESSED CEILING WHOLE cn WINDOW WITH OUTDOOR Vim <br /> V <br /> WHF HOUSE EXHAUST FAN AIR INLET • <br /> 80 CFM MIN., 120 CFM MAX., <br /> 1.5 SONES, 6" ROUND DUCT SPB PUSH BUTTON <br /> VTR VENT THROUGH ROOF o Job No.: 13-47 <br /> L <br /> H. Sheet No.: <br /> z <br /> U 12 <br /> 9' <br /> Sheet Order: A B U F R E S D <br />