Laserfiche WebLink
_ <br /> __Sl� SIDING - SEE ELEVATIONS T <br /> � FOR TYPE �� 5 <br /> '' W.R.B. (TYP.) �UNIT 7 ii�i��i 1" D1 . <br /> �� <br /> �::I �i SEE DETAILS 8/11 AND 3/a" T&G PLYWOOD SUBFLOOR UNIT UNIT �'i�ii/i ;ii - <br /> � � � 17/11 FOR INSTALLATION OVER 2X FLOOR FRAMING � � 2 2 <br /> ; ; �� � 16" O.C. U.N.O.— 1Y" FLOOR SHEATHING <br /> � � � ' <br /> - ; . <br /> HEADER PER 1 ; � � ' <br /> „ � <br /> ' i 2 6 ; � z � 2 X 12 STRINGERS � '��''!'�'�''�'' ; .: �� <br /> � STRUCTURAL �f , ; ; ��. � SLOPE z 2 2 AT 12" O.C. - r,,�;;r�ir ii i��i 1 �:: <br /> . <br /> � <br /> � <br /> � � " � \ 10° MIN. �Xg GARAGE T to io � � �, <br /> 0 <br /> �.:{ � � � 1 x8. ,:...._.-_._ } <br /> � , � � 1Ya" FLOOR SHEATHING 2x12 STRINGERS ��� � � � r� ;� �� '��� l :� <br /> � ( PROVIDE R-30 WSUL. <br /> GWB � ' � � ' �!r�f��� �� OVER UNHEATED AT 12" O.C. 1 <br /> ; z PROVIDE R-30 INSUL. �` � � � � � � �' � � <br /> � PROVDE SEALANTLENDI DAMS ,. ... .. ....:.. . .. .. .. :..._ ; . , .� .,.... . .,,..,. .. . :, . .,. .....�, SEE UNIT STAIR SPACES. i,iiiiiiirri�>!� OVER UNHEATED � ; � � i F <br /> � : ... ... ... ... .... .... : .. . . . . <br /> C � AT EACH END PLANS FOR RISER 6 4 (1) LAYER SPACES. ��:����������` �an�t98 33 •. <br /> �� 5/a EXTERIOR TRIM (TYP.) DIMENSIONS. 2 6 5/a" TYPE X GWB � � �� � <br /> r" ----- ; SEE ELEV. FOR WIDTH (1) LAYER 5/a" GWB (1) LAYER ;� ��`��1��� E;42S6S812�}8 <br /> � � <br /> , (5/a" TYPE 'X' GWB IA/ITLJ UNIT z 5/a" GWB { V�el� �twv�,t�t�.�C��d#"ct�`�h�t4�1 ` <br /> SEALANT , �(���SEALANT AND BACKER ROD R-30 WSULATION WHEN R-21 WSUL. <br /> � PROVIDE 2x8 BLOCKING PER MFR INSTALLATION OVER GARAGE) <br /> (FOR DRAPERY) EACH SIDE REQUIREMENTS SEE UNIT STAIR 5052 REGISTERED <br /> OF HEAD AT ALL BEDROOM PLANS FOR RISER � ARCHITECT <br /> AND GREAT ROOM WINDOWS �-VINYL SLIDING GLASS DOOR AND TREAD <br /> (TYP.) DIMENSIONS. � <br /> PATIO DOOR HEAD INTERMEDIATE STAIR LANDING STAIR DETAIL AT GARAGE TOP OF STAOR DETAIL ROBERT E. WEIBLE ; <br /> 1� ^ � � STATE OF WASHINGTON <br /> U <br /> 3°� _ ��-o�° SECTION ' 1 1/2" = 1'-0" SECTION 1 1/2" = 1'-0» SECTION 1 1/2" = 1'-0" SECT�ON <br /> 1" T � T � <br /> � � � <br /> I 5 � ��� f � <br /> PROVIDE BLOCKING FOR ; Di !�if ii�iri' �fi � 'ii� /�ii�i!�i��i °' <br /> TRIM AND SIDING FIN. FL. I ';� 2 6 .: „ ��������� 1Ye" FLOQR �^ <br /> GWB � ; 1Ye FLOOR SHEATHING T � � 1Ye" FLOOR � � SHEATHING � <br /> � <br /> - — � 2 SHEATHING Q <br /> � — — � � , � ; � � 2x12 STRINGERS 1" 1" <br /> 2 2 � A T 12" 0.C. i/�ii/ii�ii�i%i T . <br /> i. SEALANT � � , � , <br /> i c //�ii ii�i//i//i 2 X 12 STRINGERS 2x12 STRINGERS i if/ii/ii/ii/ii/ � <br /> � <br /> ' ;< EXTERIOR � I � � 1 x8 PROVIDE R-30 � <br /> —AT 12" O.C. AT 12" O.C. z <br /> , ; � ' g INSUL. OVER r — <br /> � �o � PROVIDE R-30 INSUL. p5 UNNEATED <br /> SLOPE ; OVER UNNEATED 1X8• 20A 5 1x8 ;� <br /> , 10° MIN. � 2 =� � SPACES. SPACES.- PROVIDE R-30 INSI. � <br /> � 6 6 � - `� I 2 6 ' �� � � (1 LAYER 5/a" GWB 2x12 P.T. �� p� 2x BLOCKING OVER UNHEATED � <br /> � �-. � BOTTOM PLATE SPACES. v <br /> , LG�IRAGE� �e TYPE X GWB 2 z �- <br /> � -. a . a a a � <br /> '_ :i ' d ° a aQ , , . Q , d o <br /> ---- —,-- --- -------- d � <br /> -------------- - -==�- --- --- I � d d , a , 4 . a . a � � <br /> _ ___ ___ __ _ (1 LAYER <br /> � HEAD ' a a a a. a a 5/a" GWB � <br /> � '��_. � � � a � �� � a o ; <br /> ----------------- a, . ; <br /> SIDI�NG, SEE ELEV.� FLASHING (, (1) LAYER M <br /> FOR TYPE SHIM, PER DOOR 5/a" TYPE X GWB " ° BEAM PER STRUCTURAL --- '� <br /> MFRS REQUIREMENTS ' � �fz" GWB MIN. AT GARAGE �o ta � a .�.' <br /> SEALANT PER SIDING (, :� � � �-- <br /> � , ���-��-����-���-� i �-���-1I �-���-���-� I -II �-���-��� ���=i o o ,� <br /> MFR INSTALLATION i �� ��' <br /> SEALANT AND BACKER ROD 2x10 TRIM � I I I=I I I=I � I=) I � � <br /> . <br /> �� REQUIREMEN TS— =� SHIM AS NEEDED � -I I �=I I I-I I I=) � I=I I I=I I I=I I I=I I ( -I I I-I ( I-= �-�� - �-�-��- � � ��� � ������ � � � � ��- � ���� � � ���-��� � � �� � �. ��� �- <br /> PER DOOR MFR INSTALLATION , � ' '-' � '-�j�=1 I I i I I-f � (-) I I-! � I-1 i f-I t �-� � (- � <br /> REQUIREMENTS ' � -I I (,_, ,I I I, ,) I I-���- o � � <br /> FLASHING SYSTEM � z Q <br /> SEE DETAILS 8�11 %4X5Yz EXTERIOR TRIM (TYP.) ''�� � � HEADER PER SEE UNIT STAIR SEE UNIT STAIR SEE UNIT STAIR _ � <br /> STRUCT. <br /> PLANS FOR RISER PLANS FOR RISER PLANS FOR RISER <br /> AND 17/11 SEE ELEV. FOR WIDTH _ AND TREAD AND TREAD AND TREAD <br /> 2x HEAD TRiM 1--r j� -° DIMENSIONS. DIMENSIONS. DIMENSIONS. � <br /> SLIDING PATIO DOOR JAMB TYP. GARAGE HEADER BOTTOM OF STAIR � LANDING BOTTOM OF STAIR � CONC. B�OTT Ca►vl OF STAIR � � <br /> 18 14 10 6 2 <br /> � N <br /> 3" = 1'-0" P�N 1-1/2" = 1'-0" SECTION 1 1/2" = 1'-0" SECTION 1 1/2" = 1'-0" SECTION , 1/2" = 1'-0' ' SECTION � � <br /> 0 <br /> ' INTERIOR ,�. u � EXTERIOR � I T <br /> � INSULATION AND ENERGY NOTES .. � <br /> �1 SIDING - SEE ELEVATIONS RIPPED 2x8 FRAMING � �` �ii r�;ii yrr;;i c � � o <br /> ;i FOR TYPE 16" o.c. FOR LANDING 1Y8" FLOOR , � L o N . <br /> -� 2 6 i�' W.R.B. (TYP.) SEE STAIR PLANS FOR � SHEATHING— � � ���d ��$ � 0 0 <br /> � � SEE DETAILS 8/11 AND LANDING HEIGHT 2x12 STRINGERS 1x8 A l l insu la tion ma teria ls s ha l l be ins ta l le d accor ding to t he manu fac turer's A l l ex terior doors or doors serving as access to an enc lose d un hea te d ,� Q <br /> ;:� ; ; FOUNDATION OPENING instructions to achieve ro er densities, and maintain uniform R-values. area shall be weatherstri ed to limit leaka e around rtheir erimeter when in a <br /> SEE STRUCTURAL ; ; 17/11 FOR INSTALLATION -�- - %z" GWB (MIN.) AT 12" O.C, p p pp g p � 0 <br /> FOR HEADER SIZE � ' ' --SHEATHING = DOOR SIZE � o Substantial contact of the insulation with fihe surface being insulated is required. closed position. � <br /> . OVERHEAD DOOR PROVIDE ��%��������i�������%���� %�i��r��r�%����f r�%�� Where required, insulation shall be installed with clearances according to The thermal transfer characteristics of insulated doors shall be U-value 0.30 �"'� N <br /> � ; I %a" MIN. GAP SYSTEM BLOCKING FOR ° manufiacturer's specificatians. Insulation shall be installed so that required or better per WSEC section R402.1.1. � L <br /> ��� TRIM AND SIDING - <br /> � ; � � o � ventilation is unobstructed. For blown or poured loose fill insulation clearances }� � <br /> I m <br /> ' � ��� 2x BLOCKING � o shall be maintained throu�h installation of a permanent retainer. � 3 <br /> � I 24 GAUGE PPM FLASHING 2 2 2 (1) LAYER ���W� o <br /> , � i I ° 5/a" GWB Glazing U-values for windows and SGD shall be U-value 0.30 or better per <br /> j.,. � � FLASHING SYSTEM S� a1 G�at�9 WSEC section R402.1.1 as indicated on the unit plans. <br /> ; s s s �� HANGER PER R-10 slab on grade insulation shall be installed inside the foundation wall and Windows shall be fumished with outdoor air inlets as indicated on the Unit <br /> ; 2X TRIM _ ____ _a�_ o STRUCTURAL A <br /> ; SEALANT PER MFR shall extend down vertically 24 or to the top of the footing whichever is less Electrical plans. Inlets shail have a controllable and secure opening and be � <br /> � INSTALLA710N Y� SIDING SEE ELEV. ° BEAM PER STRUCTURAL per WSEC section R402.2.9. capable of a total opening area of not less than four (4) square inches and <br /> REQUIREMENTS FOR TYPE, INSTALL PER � tested by a nationally recognized standard or approved agency and located � � <br /> ! 5/a X 5Y2 EXTERIOR TRIM (TYP.) MFR REQUIREMENTS to avoid drafts. Inlets shall be screened or otherwise protected from entry by a •� <br /> DOOR FRAME � 5/4X5Y2 EXTERIOR TRIM (TYP.) SEE ELEV. FOR WIDTH FLASHING SYSTEM ° t1S1�Qt9C� AOf�f8 insects, leaves, or other material. �^ � <br /> 2x BLOCKING � <br /> !N-SWINGING SEE ELEV. FOR WIDTH AS NECESSARY SEE UNIT STAIR Floor insulation shall be installed in a permanent manner in substantial <br /> DOOR- SEALANT PER DOOR MFR SEALANT PER MFR PLANS FOR RISER contact with the surface being insulated. Insulation supports shall be installed so <br /> - INSTALLATION REQUIREMENTS INSTALLATION � PER P�ANS AND TREAD spacing is no more than twenty-four inches on center. R����� <br /> _ EXTERIOR REQUIREMENTS �� � DIMENSIONS. Floors separating conditioned space from unconditioned space shall have a Roof/Ceiling insulation: Open-Blown or poured loose fill insulation may be <br /> vapor barrier installed. Vapor barrier shall be installed on the warm side of the used in attic spaces where the slope of the ceiling is more than 4 in 12 and '�"r <br /> � EXTER I O R DOO R H EAD insulation. The va or barrier shall have a one erm dr eu ratin or less (i.e. there is at least 44 inches of clear distance from the to of the bottom chord <br /> CARAGE DOOR JAMB BOTTOM LAN D I N G � STAI R four mil. polyethylene or kraft faced material). phe floor sheathing may be used of the truss or ceiling joist to the underside of the sheatpng. When eave vents � <br /> 19 _ _ _. _ _ 15 11 <br /> 3" = 1'-0" SECTION �-,�2" = 1'-0" P�./�N 1-1/2" = 1'-0" SECTION as the vapor barrier if rated (and so stamped? at one perm (maxJ Otherwise are installed, baffling of the vent openings shall be provided so as to deflect � <br /> place vapor barrier on top of joists before placing sheathing. the incoming air above the surface of the insulation. Baffles shall be rigid � �+ <br /> material, resistant to wind driven moisture. When feasible, the baffles shall be O C <br /> installed from the top of the outside of the exterior wall, extending inward, to a � tQ <br /> PROVIDE BLOCKING FOR � EXt6IlOf WC/E point six inches vertically above the height of noncompressed insulation, and Q,� � <br /> TRIM AND SIDING 2x8 FRAMING � All wall insulation shall fill the entire cavity. Exterior wall cavities isolated twelve inches vertically above loose fill insulation. Baffles shall be in place at � � <br /> � INTERIOR ( - � ��---EXTERIOR TRIM AT � � 16" o.c. �� ' during framing shall be fully insulated to the levels of the surrounding walls. All the time of framing inspection. Q� � � <br /> / GARAGE DOOR JAMB '�- �' faced insulation shall be face stapled to avoid compression. Where the ventilatlon space above the insulation is less than an average of W Q p U <br /> r Walls separating conditioned space from unconditioned space shall have a twelve inches roof ceiling assemblies shall be provided with a vapor barrier � � <br /> i <br /> � � �. ..= � � � � :-. � ' HANGER PER i vapor barrier installed. Faced batt insulation shall be face stapled. Vapor having a 0.5 perm cup rating or less. Faced batt insulation where used as a � C <br /> i. !,___ I �--SECTIONAL OVERHEAD STRUCTURAL � �� barrier shall be installed on the warm side of the insulation. vapor barrier shall be face stapled. � ,C N <br /> ( 2 2 � �. � DOOR TRACK AT SIDES 2x BLOCKING- ° � a � N� � <br /> ; ;� ; OF OPENING Vapor barriers shall not be required in roof/ceiling assemblies where the Q � <br /> � ' ----- ' , � , ventilation space above the insulation averages twelve inches or greater. � <br /> � '_L__ � <br /> EXTERIOR � i � ��� Vapor barriers shall be installed on the warm side of the insulation. � � � . <br /> N These air leakage notes apply to those locations separating outdoor � ; � <br /> FLASHING SYSTEM ambient conditions from interior spaces that are heated or mechanically cooled. V � �? � <br /> � 6 6 SEE DETAILS 8/11 SEE DETAIL 11/D2 Exterior joints around windows and door frames, between wall cavities and �T9�8 ■ . � O G� Z <br /> � FOR GARAGE SLAB <br /> AND 17/11 5 window or door frames, openings between walls and foundation, between walls Fireplaces shall be provided with each of the following: W � <br /> ________ _ _____ ____ AND APRON D1 and roof and wall panels; openings at penetrations of utility services through a) Tightly fitting flue dampers, operated by q readily accessible manual or ~ W = <br /> .� „ walls, floors and roof; and all other openings in the building envelope shall be approved automatic control. � � <br /> SLOPE TOENAIL 2x6 � 16 o.c. <br /> SIDING, SEE ELEV. 0 - sealed caulked, gasketed, or weatherstripped to limit air leakage in a manner b) An outside source for combustion air ducted into the firebox. The duct � <br /> FOR CEILING fRAMING ' �► <br /> FOR TYPE SHIM PER DOOR BEAM PER approved by the building official. shall be at leqst six square inches and shall be provided with an = _ <br /> MFRS REQUIREMENTS STRUCTl1RAL � o erable outside air duct dam er. � <br /> FLASHING SYSTEM -\ P P � <br /> � SEE DETAILS 8/11 SEALANT PER MFR (1) LAYER c) Ti htl fittin <br /> � g y g glass or metal doors, or flue draft induction fan or as � Q �. <br /> AND 17/11 INSTAL�.ATION a �/a" GWB approved by the Building Official for minimizing backdrafting. � � <br /> SEALANT PER SIDING EXTERIOR REQUIREMENTS 4 d) Include elbows for offsets to framing as necessary. ' <br /> - - - .- r <br /> MFR INSrALLATION 5/aX 5Y2 EXTERIOR i-1 —i I—� i I�-fI �-11 � - -2x BLOCKING � � <br /> REQUIREMENTS TRIM (TYP.) - SEE _�� �` I—I � I — I-1 PER PLANS Q � <br /> ELEV. FOR WIDTH = <br /> � <br /> EXTERIOR DOOR JAMB GARAGE DOOR THRESHOLD RAISED FLOOR � STAIR CEI LING � <br /> � 2 0 16 __ _ _ _ 12 0 �ob No.: 13-47 <br /> 3" = 1'-0" P�N 3" = 1'-0" SECTION 1-1/2" = 1'-0" SECTION � Sheet No.: <br /> � D5� <br /> Sheet Order: A B U F R E S D I � <br /> _ <br />