LIGHT FIXTURE SCHEDULE I-� K L. o a 0 o
<br /> MARS TYPE MFG./MODEL No WATTS REMARKS -_ SYMBOL
<br /> ___, p:
<br /> 2
<br /> P 2x-,TROFFER 1- LITHONIA 105 PARABOLIC '
<br /> 2PM3 GB 332 18LD 120 GEB LAY-IN MOUNTED
<br /> F: 1 2..,2 METAL 1Ai-IDE- L.ITHON1A 420 PARABOLIC
<br /> O
<br /> 400WAT; GP 400M 9A LAY-IN MOUNTED .: ,-- — --- - __- — —��
<br /> 0
<br /> F3 RECE55ED AN LITHON1A AFV 1,26 TRT BAR 120 GEE 32 CEILING __
<br /> FLUORESCENT CAN LT. --- —�-: 0 \ — -.7' Tr— _— —a- - -- L a --
<br /> F4 4RECESSED CAN LITI-401,1A AFvw 1/26 TRT OAR 120 GEE 32 WALL WASH CAN LIGHT t�~ -1-1
<br /> FS — 2Y4 TROFFER LIT,-101.4[A 105 PARABOLIC ` i
<br /> 2PM3 B 332 18G.D 120 GEE, SURFACE MOUNTED It 13,11I
<br /> F6 METAL HALIDE T LITHONIA 420 SHOP LIGHTING
<br /> _ LOW BAY INDUST Tx 400M A30 277 X11 ; i GL'LEVEL
<br /> • F7 - FLUORESCENT — LITHONIA 96 MOUNT TO STRUCTURE F NI! S' "AFF
<br /> DEL STRIP LI:�ITING C 9618 277 LPF FI0 F10 '
<br /> FS EMERGENCY EXIT LITH.:3NA 1 CEILING HUNG ' i
<br /> LIGHT LE 5 W i-G-120-EL-N _ 1 $31 1 I OPEN TO ABOVE
<br /> F9 VANITY LIGHT I LITHONIA 45 WALL MOUNT • • r GWB CEILING IN I I ----:--
<br /> WS 132 AI2 120 CORRIDOR • Fb.:
<br /> i
<br /> F10 RECESSED CAN LITHONIA 32 CEILING MOUNTED
<br /> EMER'aENCY BALLAST - AFY 1/26 TRT BAR 120 GEE ELR ll • 1 I -GWB SOFFIT 0
<br /> F10 GARAGE LIGHT LITHONIA 00 CEILING MOUNTED
<br /> KPS 100M R2 120 - , �t�1
<br /> F11 2X2 METAL HALIDE LITHONIA 420 PARABOLIC F10a o F1m F3
<br /> 250 WATT GP 250M 9A LAY IN MOUNTED -V`
<br /> FI2 ATRIUM FIXIURSS !-IESSAMERICA 400 PENDANT a—' —!
<br /> NV 260L-X MOUNT - .
<br /> ��F A
<br /> q_,_, \�
<br /> . ,,
<br /> i 1
<br /> . o
<br /> LIGHTIf�IiCs 3U GET a J" •`` 3 1''
<br /> ALLOWABLE' ��.. F10 FIO
<br /> OFFICE,COMMON AREA 120 W/SF 7,936 SF Ir�'l � �,} GWB SOFFIT
<br /> 9.523 v, 9'_2"AFF
<br /> RETAIL AREAS 1.00 W/SF 3,734 SF = 3,734 •
<br /> 3
<br /> STORAGE s MECH 050 W/SF 1,661 SF • 831 _ N
<br /> PARTS L50 W/SF 5260 5F • 7,890 - • ( f ,
<br /> SHOP 150 W/SF 9516 SF 14274
<br /> ® 3 OPEN TO ABOVE 68
<br /> LOCKER SHOWERS 0380 W/SF 558 SF • 446 r�
<br /> CONFERENCE ROOM 2.00 14/SF 367 SF ■ 734 Flo Fim - $3 .. Pla
<br /> LUNCH ROOMS,CAF L50 W/SF 874I @ n
<br /> o
<br /> 7 SF • 1,311 ® ,/
<br /> E=1
<br /> PARKING GARAGE 020 W/SF 5892 SF • 1,178 _ I G,1 _ O
<br /> TOTAL 35,798 39,922 (� �] ��'`'''�J
<br /> II • EXPOSED STRUCTURE IN �3' ;, I g.1
<br /> Q
<br /> INTERIOR ('WSEC,TBL 15-I,FOOTNOTE 7) STORAGE ROOM AND GARAGE 0,1j-0, • Pg
<br /> ACTUAL: WITH SPRAY ON FIRE GWE SOFFIT M 'rs
<br /> Fl 2x4 TROFFER 3 LT 105 W/FIX 88 FIX • 9240 L PROOFING FOR I HOUR rt II' 9'-10"AFF
<br /> F2 2X2 METAL HALIDE 420 W/FIX 19 FIX • 7,980 RATING 0 '- ori --'
<br /> F3 RECESSED CAN 32 W/FIX 84 FIX • 2,688 F10 FIm -. $3 1 ,, . - li—
<br /> F4 RECESSED CAN 32 W/FIX 4 FIX • 128 - I I 1 A
<br /> F8 2X4 TROFFER 3 LT 105 W/FIX 13 FIX • 1,365 i1112 1
<br /> F6 LOW BAY INDUSTRIAL 420 W/FIX 14 FIX • 5000 - \L l OPEN TO ABOVE 2f
<br /> F7 STRIP LIGHTING 126 W/FIX 46 FIX • 5,796MOUNT FIXTURES
<br /> F8 EXIT LIGHTS I W/FIX 14 FIX • 14 ' TO STRUCTURE 1 $3 WF9 VANITY LIGHTS 45 W/FIX 7 FIX • 315 I _ - -
<br /> F10 GARAGE LIGHTS 120 W/FIX 12 FIX 1,440 _� I I
<br /> FR 2x2 METAL HALIDE 270 W/FIX 11 FIX = 2,970 - 1/41A77:1 y I CLG LEVEL
<br /> o
<br /> P2 ATRIUM PENDANT 400 W/FIX 3 FIX ■ 1200 r F10 F10g�_6�'AFF
<br /> 3
<br /> TOTAL 315 39,016 lL
<br /> 0 F7] .. .,.. cz3!
<br /> -- — — — 5 -- — m =- __ � - U3
<br /> 0
<br /> VIII i 1
<br /> • F r-- =• -=�.V_ _ Mf TCH LIN Inl�n•I
<br /> Cr) II
<br /> Ff _FR------ --- • alN
<br /> . ________1_1:---_--------
<br /> . ul pnwnul
<br /> n
<br /> 16.
<br /> !BASEMENT PLAN FR .FR -. �FR��=• -- •---E IFS 50F1^I T ��l I
<br /> .6\..
<br /> , - — — R. .„1,1
<br /> ,.,I,
<br /> ..,
<br /> ,,,L Ili 1j11 1, 111
<br /> nl,l: dA,I
<br /> �;i�'�' ,1111�Ili
<br /> l
<br /> .',
<br /> Ell'I.0
<br /> TII i,
<br /> 1st FLOOR REFLECTED ° ",.
<br /> �ii��'1 ,A,„,1 i Iii
<br /> CLG PLAN (NORTH) /\ ,,,,
<br /> Nur ISI,' MjNI I��..
<br /> yap,,1,-m" 7,
<br /> li i, IF. 1
<br /> STUDCO-5-3-9'e"x 18 GA.STRONGBACK REQ'D pn EXISTING TYPICAL,12 GA VERTICAL (2)N0.12 GAGE WIRE HANGERS CONNECTED "I' „iI
<br /> WHERE LENGTH OF BRACE EXCEEDS 11'-6". �� STRUCTURE HANGER WIRE AT 4'-0"EA WAY FROM THE FIXTURE HOUSING TO THE STRUCTURE �`I!,'IR�` ll,
<br /> ' W/MN.3 TIGHT TURNS N I-1/2" ABOVE.(THESE WIRES MAY BE SLACIN). ji
<br /> ,' ,,IIII I`
<br /> RUN FROM MIDPOINT OF BRACE TO BOT. ;' %2"x"SCREW I
<br /> C� i.
<br /> E 1,11,11' ',1
<br /> OF NEXT BRACE. ATTACH EA END OF THROUGH HORIZ LEG BOTH ENDS OF WIRE. 1 —"(2)1 1/2'x 1 I/2"x IS GA ��11111)I Ii 0
<br /> STRUT FASTENED TO STRUCTURE11
<br /> STRONGBACK H/1-.6 x 2 SCREW �L 'WI/216-1'6i
<br /> 1,,2"x 18 GA ABOVE. LOCATE AT EACH LATER-
<br /> ' x2P61/2:'W/2-Yox2" © • '�
<br /> :...1,190)..1SCREWS EACH END SEE DETAIL f FOR REQUIRED I 12 GA BRACING WIRE W/MIN.4 AL BRACING POINT$SCREW TO REVISImourrom ON �nry(2)5-3-V'"x 18 GA.STUDCOOF BRACE COMPRESSIONS TS AT 45' TEES A10T 12'-0'O.C.MAX.
<br /> a �� A
<br /> TIGHT TURNS IN 1-1/2 BOTH �► OR MFGR DESIGNED f�TRUTS - -
<br /> (2)"6 x 2"SC WS IT-0'OL.BRAGE5 S 8'-0"D.G.WHERE � — ENDS OF WERE TYPICAL.
<br /> LENGTH OF BRACE EXCEEDS 11'-b" IN HORIZONTAL LEG OF 111N1
<br /> 'Q1- ISS PERMIT 09/23/98 ADS
<br /> .L h2 GAGESPLAYWEREBRACING Iss OWNER 1009/98 ADs
<br /> PROVIDE STRONGBACK PER NOTE MIN.SECTION PROPERTIESABOVE. (BRACE d STRONGBACK) ` " / S nN PLANE OF EACH RUNNER ISS BIS 10/19/98 ADS
<br /> TVP.INT.PARTITION A=311 int _ - W VERTICAL ANGLE'45'
<br /> I y 0697 Int NltiNs..,...
<br /> \
<br /> NOTE:BRACING MAY 8E OMITTED WHERE CROSSWALLS d� �� 1 . _ <4,45'1% _ r
<br /> 90'TO PARTITION,d�-, LEAST 4'-6' IN LENGTH I OCCUR Ate"-
<br /> �' ` , "�y NOTE-HANGER WIRES 4N"$45' ,..,...r.-,�, e
<br /> A MAX.OF al-0"ALONG A RUN OF PARTITION. _ MAxMP) I \ ARE IN THE SAME VERTICAL 'y
<br /> PIAT T 11..J1�l It l� DETAIL ''' .t-::„ M'�,V /'� PLANE AS THE MAIN RUNNER 91P40/14t'
<br /> II
<br /> 1"■I'-0" CROSS RUNNE ` HANGER WIRES'4E"t E4W".ARE IN r,
<br /> CT;
<br /> ,..#0#°*''':,,,,,,
<br /> ,� R R A \ .14
<br /> r
<br /> \\' ` �/ CROS RUNNER T-MAIN RUNNER O MAIN AL ANE RUNNER
<br /> TRUSS OR BEAM____A_
<br /> „ -` '0�, SHEET TITLE
<br /> CONT BLKG TO SEAL ' f-,�° /': TYPICAL CEILING BRAC:N5 let FLOOR REFLECTED
<br /> DRAFT '1;A CIELING PLAN
<br /> '�� V"GWB OR PLYWD, 2'(MAX)FROM BRACING WIRES ( i;„
<br /> � 8'MAX 8'MAX _ " SOUTH
<br /> Illir
<br /> TO CROSS RUNNERS. R I/4 CLEARANCE
<br /> EXTEND TO ROOF DECK
<br /> BRACE 8"0C �� imp
<br /> S'
<br /> WOOD STUD MAIN RUNNER FIXTURE SHALL BE POSITIVELY ATTACHED TO S
<br /> •'-0"OC SUSPENDED CEILING SYSTEM WITH 1/2"LONG r
<br /> NOTES: SELF-TAPPING SCREW OR APPROVED CLIP mil
<br /> ATTACHED AT STARTING CLEARANCE AT OPPOSITE 13�0 D 33 1 •
<br /> — I. SEAL DRAFTSTOP TO CAPABLE OF RESISTING 100%OF FIXTURE AND ONE ADJACENT WALL WALLS(NOT ATTACHED)
<br /> US CEILING WALLS AND AT ALL WEIGHT ACTING IN ANY DIRECTION.(2)PERsY:
<br /> PENTR.ATIONS FIXTURE,ONE AT EACH END. RUNNERS AT WALLS / I'-0" G G
<br />! 2. SET PER AT D /23/98 ADv UY:
<br /> NEAREST TRUSSSS O OR
<br /> CODENAREA.REQUIREMENTS SUSPENIDEED CEILING L IGI-IT FIXTURE IN SUSPENDED SEISMIC 'r 8`0 2 01J
<br /> (T' DRAFT STOP
<br /> E.j)
<br /> SUPPORT !BRACINC4 NO SCALE C ILIN SUPPORT © 3i�/4GINC D TAIL.• , NO SCALE SHEET N21%"=1'-0" NO SCALE 2
<br /> 68l6EvergreenWay •
<br />
|