Laserfiche WebLink
RO D L.A.N D TOYOTA. <br /> } <br /> m <br /> 7 TOWNSHIP 28 N , RANGE 5 E , W. M .SECTION , Z <br /> O <br /> I= <br /> L=22.47 N 89'01'40"W _ — — — — — — <br /> a. <br /> ' <br /> ____ ____-_ MAD1soh sT <br /> N w <br /> R=14.00'`,I e=91'56'33" __ <br /> 0 <br /> r1 <br /> ; <br /> q \� ,-- 0=97'40'07"R=24.00' L=40.97' 60" WI <br /> 0 <br /> 01.f, <br /> ROLLLS. USERISTAPLESRIORL WIRE RINGS Q <br /> 89G'=14 W ::_ 109.12 TO ATTACH FABRIC TO . O <br /> S'UTILITY EASEMENT PER WIRE 2" n 2" <br /> . \_...SILT FENCE REc.Noy: _„_ 2 X BY 14 GA. WIRE 2 X BY 14 GA. WIR " <br /> r .. <br /> N <br /> i \ OI (TYP,.) �i�� ' - FABRIC OR EQUIV. FABRIC OR EQUIV. 6" <br /> CONSTRUCTION 0�-- MIN. �' <<<<<<< <br /> ENTRANCE <br /> �:�: <br /> s 67.78 39 FILTER FABRIC <br /> 107 a <br /> ' E <br /> 7, <br /> -33v MATERIAL. <br /> CB INLET 7 a ... a Y al <br /> 0 0 <br /> t` S �. I S - �•.v •... <br /> CONSTRUCTION Pf20TECTION (TYP.) 0 30 60 I I •�. ��. �> <br /> ENTRANCE 1 N 8'08'34"W ��. I ~T <br /> • <br /> 7.58 <br /> ' O `r <br /> { HORIZ SCALE ��.�/.�/ �, �O��j� N W: <br /> p <br /> L <br /> '• <br /> NTA 'BURY BOTTOM OF FILTER MA 'IAL X. �: • <br /> u, IN 8" BY 12—TRENCH ;.r� <br /> �.. i <br /> , <br /> 8 MIN. <br /> In <br /> I <br /> y <br /> bso -A <br /> " <br /> 6' (MAX)(MA ) 3/4" 1 5" <br /> z GRAVEL TRE WASHED <br /> X � <br /> o z BACKFILL <br /> L:.-._.._ " PARCEL C �' AND ON BOTH SIDE OF NC <br /> -N_ <br /> 2"X4" WO <br /> OST, STANDARD OR BETTERFABRIC 0 <br /> OR EQUAL ALTERNATE STEEL FENCE POSTS <br /> N 2"X 4" <br /> ODP FILTER FENCE F <br /> i . lTHE SURFACE. <br /> , W WOOD POST, <br /> ALT: STEEL FENCE POSTS. <br /> r r I <br /> „ Z ; SILT FENCE DETAIL <br /> OHP LIMITS OF PARCEL B N.T.S. <br /> CLEARING (TYP.) (IF NECESSARY) <br /> a. <br /> i C.L <br /> I " ' N I81'20'45 <br /> 74 IDEWALK EASEMENT PER <br /> i <br /> f , <br /> ' :: <br /> "' REC.NO 9506200363 <br /> i <br /> 128.49' - a <br /> N O'3�'S8"E I. '._+ t <br /> 717.36' is `_ i <br /> GRATE7STANDARD STRENGTH <br /> �a �� = FILTER FABRIC FILL FOR LANDSCAPING <br /> 1 1 (� <br /> _ OR SOIL AMENDMENT <br /> �— �/ \\/`/\/ �'--\\0,,, <br /> \\j/�^ �,� \�/ /���T`/� ADJOINING PROJECT ALLOWED W IN 2' OF FI' <br /> • \�.\�/!�/i\�\\\--\, /\y\r- ... '���/ // ��%,��/ / PROPERTY SITE J / <br /> , ` i--_ 1 5'UTILITY EASEMENT PER <br /> � //\/\\\ //\ \ r/��� \/� //� P!� <br /> a . -----------------1---- <br /> REc.No.�33soa2. -'4'"\\-'''''''\''\ <br /> \i\\\ \i��\\i�� FILTERED ��/�� // //�� 1\`t` <br /> o �{--- A��a. WATER �/ _ 2 \\... <br /> \, <br /> I <br /> CATCH OR 1/2 HEIGHT OFFILL 2. <br /> 0 I5 E OR 1/5 HEIGHT OF CUT M <br /> f 235 09 <br /> , N 8'39 1 �� <br /> , <br /> BASIN <br /> i <br /> N Lf) <br /> W D7 <br /> �� CATCH BASIN INLET FILT R <br /> - - - W � PARCEL A °Hp---__ �I GRADING SETBACK DETAIL i ti <br /> _— PAVED AREAS <br /> I N.T.S. � < MN <br /> OHP =�P _ i N.T.S. <br /> t <br /> N N <br /> U W <br /> k cn <br /> EASEMENT PERr I O <br /> q LU <br /> SIDEWALK <br /> 1,,f REC.N0.9506200363. <br /> I <br /> N <br /> , , <br /> �. <br /> 0 zs <br /> h <br /> , /if 4 Z <br /> v <br /> x <br /> R, <br /> fr <br /> ili g <br /> - ‘,, -',Y,,..'„',::,,,:, L.,. . :- '', ,' -',1' : : /-! ‘,, - ------ - ' . I - - , , ___ , -__., <br /> ..---0, <br /> W <br /> 0, Ca) <br /> ial <br /> -- = <br /> ' iiii� N� V W <br /> 3o., 0 i <br /> .1,-4.-di.-7.1:11:::::::.1,-.77::::,-;,,,,....r, <br /> , „ , i <br /> / . <br /> " i, t , , ,� � ,.......7 7:7:::-.;......,:f7:::::" <br /> dir i�i�ar i�i4i_N 812045 W \ ��.. �....� � ��' •--�'� C <br /> i --‘ ' ' 4. r..-.._.._..._-_....,.......... ..,,_, -5 <br /> 327.07 <br /> 0 <br /> d <br /> ,.. .1k. dor ar- i iii i i- i C <br /> i <br /> ���"`!� +ice do,�= i��ar co Z <br /> R=25.0' <br /> GEOTEXTILE .`� ::, I=cv <br /> 7 O <br /> ' • 12" MIN. `� ' \,j,\N• \O1N OF Z c w <br /> LEGEND: �,F\\.. 55 PREP z �,o <br /> CATCH BASIN CB CATCH BASIN 4'�- 8'� QUARRY SPALLS PROv`O S/EGR� 0 0 w O <br /> EJB ELECTRICAL JUNCTION BOX �NGRS —� r v Z I— <br /> ELECTRICAL JUNCTION BOX FEC FACE OF EXTRUDED CURB Q LU Q <br /> FH FIRE HYDRANT GRAVEL CONSTRUCTION ENTRANCE Z <br /> -b- FIRE DEPT. CONNECTION FVC FACE OF VERTICAL CURB CONSTRUCTION SEQUENCE: 0 Li-U) <br /> L J <br /> FIRE HYDRANT GA GUY ANCHOR <br /> GV GAS VALVE N.T.S. 0 O <br /> IE INVERT ELEVATION 1. HOLD PRE-CONSTRUCTION MEETING,CESCL TO ATTEND LJ.. 1..... C <br /> GAS VALVE LS LIGHT STANDARD 2. FLAG OR FENCE CLEARING LIMITS. I�i� Z <br /> GUY ANCHOR PP POWER POLE 3. POST A SIGN WITH THE NAME AND PHONE NUMBER OF THE ESC SUPERVISOR. +; <br /> PLU POWER POLE WITH LIGHT & UG 4. INSTALL EROSION CONTROL MEASURES +' O N <br /> Q INDICATOR POST PPL POWER POLE W/LIGHT <br /> PPU POWER POLE W/UNDERGROUND 5. CONSTRUCT CONVEYANCE SYSTEM AND INFILTRATION BASINS. <br /> LIGHT STANDARD <br /> SLL SOLID LOCKING LID SDMH STORM DRAIN MANHOLE 6. CONSTRUCT ROAD IMPROVEMENTS W <br /> 7. STABILIZE SITE <br /> POWER METER SSCO SANITARY SEWER CLEANOUT PLAN APPROVED <br /> SSMH SANITARY SEWER MANHOLE 8. MAINTAIN EROSION CONTROL MEASURES IN ACCORDANCE WITH SNOHOMISH <br /> POWER POLE (AS NOTED) TS TRAFFIC SIGNAL COUNTY STANDARDS AND MANUFACTURER'S RECOMMENDATIONS. <br /> TSB TRAFFIC SIGNAL BOX 9. STABILIZE ALL AREAS WITHIN SEVEN DAYS OF REACHING FINAL GRADE. <br /> SANITARY SEWER CLEANOUT WIP WATER INDICATOR POST 10.SEED OR SOD ANY AREAS TO REMAIN UNWORKED FOR MORE THAN 30 DAYS. EVERETT PROJ.NO. DSN.BY: <br /> WM WATER METER <br /> GRADING QUANTITIES: SANITARY SEWER MANHOLE YD WV <br /> WARERD VALVE <br /> VE 11.UPON COMPLETION OF THE PROJECT,STABILIZE ALL DISTURBED AREAS AND PUBLIC SERVICES DATE 12-0412 JMS <br /> REMOVE BMP S IF APPROPRIATE,CLEAN CONVEYANCE SYSTEM AND VAULT OF ALL <br /> CUT = 200 C.Y. STORM DRAIN MANHOLE ACCUMULATED SEDIMENT. PUBLIC WORKS DATE: <br /> FILL = 200 C.Y. - FENCE LINE AS NOTED 52/2012 <br /> TRAFFIC SIGNAL UTILITIES DRAINAGE DEPARTMENT <br /> GRADING QUANTITIES ESTIMATED — — FLOWLINE CESCL:ASP!-TERRY OSTERGAARD-425.252.1884 = SCALE. <br /> TRAFFIC SIGNAL BOX CALL 48 HOURS A PUBLIC WORKS PERMIT IS REQUIRED PRIOR TO 1"=30' <br /> BASED ON CURRENT SITE INFORMATION OHP OVERHEAD POWER LINE STARTING ANY CONSTRUCTION ON THIS <br /> & ASSUMED EXCAVATIONS NECESSARY ® WATER METER BEFORE YOU DIG PROJECT. APPROVAL FOR THIS PROJECT DRAWING NO. <br /> FOR PROPOSED IMPROVEMENTS. SANITARY SEWER LINE CITY ENGINEER !S COND1170NAL PER CURRENT STANDARDS <br /> 2 5 <br /> WATER VALVE 6816 Evergreen Way B1206-014 1-800-424-5555 Y, AND EXPIRES UNLESS PERMIT • <br /> -- STORM DRAIN LINE <br /> FOR CONSTRUCTION HAS BEEN ISSUED. of <br />