Laserfiche WebLink
RODLA.ND TOYOTA m <br /> SECTION 7 TOWNSHIP 28 N , _ <br /> , RANGE 5 E , W. M . z <br /> ,-0-.. <br /> ___ _ _ <br /> L=22.47' N 89'01'40•W 1 MADISON_ST - cUn <br /> IR=14.00' ._ _ <br /> o=91'56'33" N W <br /> 8622 Nt: =_.. .,;. o <br /> c _'_41-•, -1I. �=97'40'07 R 24.00'L=40.91' 60" WI , <br /> - = � FILTER FABRIC MATERIAL RE W <br /> - <br /> ': a RINGS <br /> �.�� ROLLS. USE STAPLES OR WIRE (- <br /> s UTILITY EASEMENT PER N 89'C3'+4"W 109.12' TO ATTACH FABRIC TO WIRE. Q <br /> �1 \-SILT FENCE REC.No:•�•�:•,.:.. ,....„4„ <br /> ' GA. WIRE WIR I <br /> 1 <br /> _ � 2"X 2" BY 14 2"X 2 BY 14 GA <br /> n (TYR.) ��% ' FABRIC OR EQUIV. FABRIC OR :::: <br /> 6"iMIN. a a a a a a< <br /> CONSTRUCTION <br /> a <br /> ENTRANCE S 67'18'39"E FILTER C <br /> 0' <br /> 0 10.77' o 'o MATERIAL. o <br /> -N CB INLET N N <br /> CONSTRUCTION ^• PROTECTION (TYP.) <br /> 0 30 60 � ,� <br /> N 8'08'34"W ��'� t <br /> ENTRANCE ' 7.56' ���� _ <br /> iiiiil <br /> . '!/ .Q'�I'�/'�/'�/'!'I'�/'4 �� :��.,� _ �„c,.t HORIZONTAL SCALE ♦ a• ,. �.Q.��.�N :r fpr r. W: <br /> w <br /> / I, BURY BOTTOM OF FILTER MA HAL ,`" <br /> `Z__ W: <br /> • <br /> IN 8" BY 12" TRENCH I y:.,f Q <br /> I N 8" MIN. O►;s `•,. <br /> a bn �I .- . <br /> 6' (MAX) u PROVIDE 3/4"-1.5" WASHED I SO(+ <br /> LJ <br /> o z <br /> " - GRAVEL BACKFILL IN TRENCH <br /> i PARCEL C " " FILTER FEN E FABRIC ON / <br /> 1 OR EQUALO ALTERNATE: STEELDFE CE POSTS. THE SURFACE. " <br /> 1 2 X 4" WOOD POST, <br /> I W r ' ALT: STEEL FENCE POSTS. <br /> 0 <br /> 2 ;: SILT FENCE DETAIL <br /> I N.T.S. <br /> OHP LIMITS OF PARCEL B I (IF NECESSARY) L.� <br /> I CLEARING (TYP.)- N 81• -I <br /> 45"w SIDEWALK EASEMENT PER <br /> ani <br /> .20' REC.N0.9506200363. <br /> _- T 128.49' I= <br /> _ Io <br /> N O'3 / CL <br /> �'S9"E � � (/)n <br /> 117.36' "_T , -��` / GRATE STANDARD STRENGTH FILL FOR LANDSCAPING v, <br /> I 1 I / FILTER FABRIC <br /> / OR SOIL AMENDMENT <br /> 44-13%110 <br /> �\\i � � �\ \\r ■ ■ ■ • �/ /�T\� ��T � //% EC A W/IN 2' OF <br /> ADJOINING PROJ T LLOWED <br /> \\.<�\i�\\i/\�\\�\\\\\\/� , ''''4 <br /> ■ ■ ■ / \\//// �/TPROPERTY SITE <br /> Q -`I 5'umrY EASEMENT PER \\\\/%\/\\/�//�Y\\ :. <br /> ./ ,• '''/ //,0 ,/� \ <br /> WATER `� F\\-\' <br /> OF' IN. <br /> CI I <br /> I CATCH OR 1/2 HEIGHTFILL2. <br /> ( ' 23509't5"E .) OR 1/5 HEIGHT OF CUT Mqk <br /> BASIN <br /> 4 <br /> I C) �T <br /> V TT <br /> W . CATCH BASIN INLET FILTER > CN c <br /> •I -_ f OHP GRADING SETBACK DETAIL ¢ . . . <br /> w PARCEL A , ---- I PAVED AREAS W Q <br /> I I N.T.S. � � c•2N <br /> Z J <br /> xi LTi <br /> OHF .-SNF Iz N.T.S. <br /> �. Yv w <br /> 1 Q 0Ct w <br /> SIDEWALK EASEMENT PER <br /> REC.NO.9506200363. 3 N <br /> CO <br /> I- ,._ ------------:- 1 <br /> - <br /> z v <br /> 4 3 <br /> 1 / <br /> IX <br /> z <br /> 0 0P CD: w W <br /> 0 <br /> 0 <br /> 1111 illV <br /> f ....._ 0,,,, EX �iGR <br /> w2 LA' <br /> ,III i... O <br /> � ILLI 30� z <br /> W <br /> __77 <br /> / / M <br /> ilei•i::::;:::!:::::::f:1:7:1:':7��, �e;--;r1:1;:,4;:i1.1.1r..�!�"� <br /> N 812045"W i 0 I �`:�,�`i�i��i�i�i�i�i:::t:���i> <br /> 327.07' I I �����` I�I�'�I�Ir'i�i�i1 0 <br /> R=25.0 ���%�iii�ii!-do. ��� <br /> %I GEOTEXTILE �w��`•�!�,'�'I U <br /> �`�..s (A Z_ <br /> I • 12" MIN. ��, M\N' \14\01\-\ .N Z c W <br /> LEGEND: FO��' SS PR , Q <br /> 8" R%._ s/t\ EpRQU O w <br /> CATCH BASIN CB CATCH BASIN 4 QUARRY SPALLS P J I- F9- <br /> EJB <br /> EJB ELECTRICAL JUNCTION BOX O <br /> ELECTRICAL JUNCTION BOX FEC FACE OF EXTRUDED CURB \ Q N w Q 0 <br /> FH FIRE HYDRANT GRAVEL CONSTRUCTION ENTRANCE: R._ <br /> Q-� FIRE DEPT. CONNECTION FVC FACE OF VERTICAL CURB Oct u- --ICONSTRUCTION SEQUENCE: 0 =GA GUY ANCHOR O o <br /> FIRE HYDRANT GV GAS VALVE T S0 Z fI O <br /> IE INVERT ELEVATION 1. HOLD PRE-CONSTRUCTION MEETING,;ESCL TO ATTEND � � � D�� 'N C O O <br /> GAS VALVE LS LIGHT STANDARD 2. FLAG OR FENCE CLEARING LIMITS. (n Z <br /> PP POWER POLE 3. POST A SIGN WITH THE NAME AND PHONE NUMBER OF THE ESC SUPERVISOR. in part,based tY cc <br /> GUY ANCHOR PLU POWER POLE WITH LIGHT & UG This ReooM thawing has been prepared, <br /> Q PPL POWER POLE W/LIGHT 4. INSTALL EROSION CONTROL MEASURES • others.Though O <br /> INDICATOR POST PPU POWER POLE w/UNDERGROUND 5. CONSTRUCT CONVEYANCE SYSTEM AND INFILTRATION BASINS. on AS-8tr�lt information provided by C <br /> LIGHT STANDARD SDMH STORM DRAIN MANHOLE 6. CONSTRUCT ROAD IMPROVEMENTS the beat it information and this drawing are based on 0 <br /> the best a labia information,no presumption should > <br /> SLL SOLID LOCKING LID 7. STABILIZE SITE s accuracy. W <br /> POWER METER SSCO SANITARY SEWER CLEANOUT mai:r= di�gthe '�- -i3 PLAN APPROVED <br /> SSMH SANITARY SEWER MANHOLE 8. MAINTAIN EROSION CONTROL MEASURES IN ACCORDANCE WITH SNOHOMISH /� <br /> -0- POWER POLE (AS NOTED) TS TRAFFIC SIGNAL COUNTY STANDARDS AND MANUFACTURER'S RECOMMENDATIONS. , c-" A Z pate <br /> TSB TRAFFIC SIGNAL BOX 9. STABILIZE ALL AREAS WITHIN SEVEN DAYS OF REACHING FINAL GRADE. <br /> SANITARY SEWER CLEANOUT WIP WATER INDICATOR POST 10.SEED OR SOD ANY AREAS TO REMAIN UNWORKED FOR MORE THAN 30 DAYS. / /t`l.'' 't. Ro1 No. DSN.BY <br /> WM WATER METER ,�. (,�7 Permttlns .....--e----- ---lam' EVERETTVERErr 12-0412 JMS <br /> SANITARY SEWER MANHOLE WV WATER VALVE 11.UPON COMPLETION OF THE PROJEC-STABILIZE ALL DISTURBED AREAS AND PUeU ERUICEs DATE <br /> GRADING QUANTITIES: YD YARD DRAIN REMOVE BMP'S IF APPROPRIATE,CLEAN ,ONVEYANCE SYSTEM AND VAULT OF ALL Print NamB Title <br /> DATE: <br /> STORM DRAIN MANHOLE PUBLIC WORKS <br /> CUT = 200 C.Y. ACCUMULATED SEDIMENT. 5/2/2012 <br /> FILL = 200 C.Y. FENCE LINE AS NOTED ,, s. 1.14 2x,„ <br /> �'°� `��`"'��`��'���`'°'�P' �'?','�'� g/ UTILITI S DRAINAGE DEPARTMENT <br /> TRAFFIC SIGNAL v' SCALE: <br /> FLOWLINE CESCL:ASPI-TERRY OSTERGAARD-425,252.1884 CALL 48 HOURS 'w, A PUBLIC WORKS PERMIT IS REQUIRED PRIOR TO 1"=30' <br /> GRADING QUANTITIES ESTIMATED TRAFFIC SIGNAL BOX STARTING ANY CONSTRUCTION ON THIS <br /> BASED ON CURRENT SITE INFORMATION ❑HP OVERHEAD POWER LINE BEFORE YOU DIG PROJECT. APPROVAL FOR THIS PROJECT DRAWING NO. <br /> & ASSUMED EXCAVATIONS NECESSARY ® WATER METER SANITARY SEWER LINE CIT ENGINEER IS CONDITIONAL PEReURRENT STANDARDS 2 5 <br /> FOR PROPOSED IMPROVEMENTS. WATER VALVE '0 1-800-424-5555 �s AND EXPIRES (0,'Z..a /.3 UNLESS PERMIT of <br /> STORM DRAIN LINE 1 v e ��� Lity �� ) FOR CONSTRUCTION HAS BEEN ISSUED. <br /> fiy <br />