February 2, 1999 <br />UBL/C I�Y00'� <br />G. Skip Downing <br />PO Box 268 <br />Green Bank, WA 98253-0268 <br />Subject: Project: Freddies Club <br />Job Address: 7903 Evergreen Way <br />Plan Check No.: B 61164 <br />Dear Mr. Downing: <br />In response to your application for a construction permit, your plans have been examined and you are <br />advised that the issuance of a permit is being withheld for the reasons listed below. These comments <br />address building issues r�nly, additional revisions or addi[ions may be required by other departments <br />(such as Utilities, Plan,�ing or Fire). All references refer to the 1997 Uniform Building Code, as <br />amended by the State of Washington and/or Washington State Energy Code 1997 Edition, unless stated <br />otherwise. <br />In order for the processin,g of xour application to continue, it will be necessary to <br />provide the Buildmg Division w�th two complete new sets of drawings reflecting the <br />corrections requested. <br />1. The building was originally an A-2.1 Occupancy and was required to be within a one-hour <br />protected building per Table 5-B. This TI creates two A-3 Occupancies, which are not <br />required to be within a one-hour fire-resistive building. As the existing rype of construction is <br />II-1 Hr, and a wooden drive through is proposed, it is suggested that the building be <br />reclassified as Type V-N (or 1-HR) construction. Allowable area justification per Section 504 <br />(including mixed occupancy calculations) should be submitted for this reclassification — and the <br />Fire Marshal's office contacted regarding upgraded fire flow requirements. Odierwise, the <br />wooden drive through should be constructed of non-combustible materials as required for a <br />Type II-1 hr building. Section 603.1 <br />2. The architect and engineer of record should sign the drawings. Section 1063.4.1 <br />The occupancies on the coversheet should be changed to show B(employee area); A-3 (cas?no <br />and bar); anci A-3 (dining room). Tables 3-A and 10-A <br />4. The exit doors leading from che casino and dining room to the exterior should be shown with <br />panic hardware unless no locks or latches are used. Note that a key-locking device may be <br />used in lieu of panic hardware on the main exit if a sign is posted adjacent to the door stating <br />"THIS DOOR MUST REMAIN UNLOCKED DURING BUSINESS HOURS." Section <br />1007.2.5 <br />Nlaximum occupan[ load signs should be posted for the casino (284 occupants) and the dining <br />room (65 occupants) and shown on the plans. Section 1007.2.6 <br />6. Illuminated exit signs should be shown [o cleazly mark the path of egress to all exterior exit <br />doors. The signs should be provided wiLh a 1-�h hour back-up system. Section 1003.2.8 <br />CITY OF EVERETT• 3200 Cedar Slreet • Everett, WA 98201 •(425) 257-8800 • Fax (425) 257-8656 <br />