Laserfiche WebLink
NO OPENINGS WITNIN 4'-0" � NO OPENINGS WITHIN 4'-0" COMPOSITION SHINGLES COMPOSfTiON SHINGLES OVER #15 <br /> METAL RAKE 2 OF PROPERTY LINE EITNER SIDE COMPOS�TION ROOFING <br /> FLASHING .. �QF PROPERTY LINE EITHER SIQE � OVER ROOF SHEATHING FELT OVER ROOF SHEATNING <br /> CENTER COMMON WALL � � OVER ROOF SHEATHING , ' <br /> � 1X3 TRIM ROOF SHTG. OVER PROPERTY LINE� ROOF SHEATHING 2x4 VENT BLOCK \� INSULATION BAFFLE SHALL EXTEND 6" VERTICALLY MTL. RAKE ' <br /> � USE SpUD BLOCKING ABOVE SURFACE OF BATT. INSULATION OR 12" FLASHING <br /> � GABLE TRUSS <br /> 2X8 TRIM � - � RAISE EL WITNIN 5'—Q" OF (2 F-- vWi ABOVE SURFACE OF BLOWN IN INSULATION. <br /> SfDING (2) LAYERS 5/s" ' 4i FIRE—RETARDANT TRUSSES A Q o � 2x OUTRIGGERS � 2x2 1x3 TRIM <br /> � �� EXTERIOR WALL SHEATHING TYPE X GWB I � ; TREATED PLYWOOD 24" O.C. � 12 SEE ROOF PLANS SEE ROOF PLAN FOR SLOPE AT 24" O.G ' <br /> EXTEND BACK TO 2x8 FASCIA '� <br /> COMP. ROOFING �`-----`} ; 4'-0' EITHER SIDE !` �—FOR SLOPE �� 12 � � , � <br /> STEP FLASHWG CONT. DRAG TRUSS � :, ' � � OF f�. <br /> � ��, SOLID 2x ,,—�` METAL z z VENT BLOCK WITH (3) NEXT TRUSS ' � <br /> END TRUSS WITH , — � >, � <br /> 2 � SCREENED VENTS. � LET—W OR HOLD :' � � <br /> �.'( " VERTfCALS AT L T U S � FLASHWG � ry � � <br /> (2) LAYERS 5/8" TYPE 'X' GYP. 24" O.C. MAX. � ; � � `� � � � �. � � � � <br /> �' USE SOLID BLOCKING I VARIES SEE DOWN TOP CHORD � <br /> SHTG.OVER GABLE TRUSS, EA. F : _ ( ; ��Q � WHEN WALL IS WITNIN ROOF PLANS OF GABLE TftUSS � <br /> ATTlC I ,: ' t ` i i Q� — — — » � FOR OUTRIGGERS <br /> SIDE SEE 17fD3 FOR 2—NOUR - � , `; � � ��°- R� �A D � �'-0 OF � � � i RkJSS �ND � �. � � � ,� .� � � � <br /> TEST ASSEMBLY DETAILS ' r, �i � z c� SEE ROOF PLANS � � METAL • <br /> � : i , i; , w T 'C NULTIN <br /> R 0 I S L. j <br /> �' � 'I I w vwi� FOR GUTTER . .......:.: ..... . .. ... ...> .,.,..�..... ..< � EAVE <br /> I <br /> � � ,� � <br /> , � �` ; � LOCATIONS z s � FLASNING i `�S Cen�i'r'�i V�ay� ' ����e 2�f(� <br /> I , � �i T P. R Q� � 4 z� s � � � TQP PLATE �� � <br /> � I � � � 17 i � ��r�l�r�d Wa�1��n ��n 4��3� : <br /> ..� 2 I � C ILI G � ' 2X8 FASCIA . ... . . . . ........ ...... .:.R. . : ..: g <br /> 2 a . . . . . . . . .. . . . . . . _ i � � �I i � ��S��4 7`��R� � 4�56�8 t2�� , <br /> D 1 i �` 2 s <br /> ... .. ... .. .... .. .. 2 s � 1 � f 17 TYP. ROOF/CLG 2 - s I � : ,. <br /> ` ��� ��u� r�o��t�pncE�a�ch �arn . <br /> 2 a �7 TYP. ROOF/CLG. � ' 4 I ' �� ' SIDING OVER D1 ; ' VARIES R � D1 ASSEMBLY , I <br /> ;.. ... � �., ,. :�... �.. .� -! <br /> ; , , 2 6 � - � SEE QOF PLA : I EXTERlOR <br /> D1 CONSTRUCTION -.,. ,.. :- .. .. �, . .., . _ ,� ..... ... :, .. .. .....: . ... .. <br /> 0 F N U o � I :' 2 4 F 2 4 ' � SHEATHING I � SEE PLAN <br /> � TRUSS HANGEft ;� 2 4 2 4 � D1 � � FOR GUTTER I <br /> U PER STRUG � �` (1) LAYER �7 , � VAR►ES SEE TYPICAL EXTERIQR WALL � LOCATlON � <br /> � 5/s GWB Q� � � ROOF PLANS I I UNIT 1 TYP. EXTERIOR WAL� <br /> n 2 4 . 2 4 . Q ca � : � � 2x8 1 D1 5052 REGISTERED <br /> � � ? TYP. COMMON 8 � ,! , FIREBLOCKING f� , SEE S SHEETS FOR �; _` I � <br /> `t Q ° 2 4 � WALL ASSEMBLY D1 � � I TRUSS BLOCKING NO WALL. OR ATTIC �_ � FASCIA -______ � ARCHITECT <br /> � TYP. COMMON 8 � FIREBLOCKING 1" AIRSPACE `r:, � ---- � <br /> ' � INSULATION AND I <br /> WALL CONNECTION — i � <br /> r� D1 '' � � � D1 BAFFLE AT GARAGE <br /> � TRUSSES PERPENDICU�.AR TO CQMMON WALL � TRUSSES PARALLEL TO COMMON WALL <br /> _ � <br /> ROBERT E. WEIBLE <br /> COMM�N W LL AT STEPPED ROOF COMMON WALL AT ATTIC C3VERHANG W/ RAlSED H�EL TYPICAL EAVE EXTERIOR WALL AT �Q4f STATE OF WASi�INGTQN <br /> 17 13 9 � 1 <br /> 1-1/2" = 1'-0" SECTION 1-1�2" = 1'-0" SECTION 1-1/2" = 1'-0" SECTION �—��2" = 1'-0" SECTION 1-1/2" = 1'-0" SECTION <br /> � <br /> TYPICAL. � <br /> f; r �:; j TYPICAL FLOOR g �:; � i, UNIT EXTERIOR �� -- � � I � <br /> , : �.; � , lAP OUTER LAYER � <br /> " � 4 z 4 , pq , � } 5 ,J > ' WALL � j OF BUILDING PAPEft � TYP. EXTERIOR WALL � <br /> �� , � �� �� : � . i g ' � , ; (2) LAYERS � TYPE X GW�3� ; , OVER FLASHING. ; � <br /> �"' � ' �' � ��' � ` � � � �' � ��� ADDED AT RATED FLOOR D1 I � INNER LAYER RUNS � I ` <br /> � TYP. FLOOR/GLG. 1 �a <br /> '�'¢ `.I° ' �r • ' �� � '' � � � ��� CONDITIQNS SEE BLDG. � BENIND SIDING <br /> ( . � I CONSTRUCTION I D1 <br /> ca- ' ,,, TYPI�AL 9ST FLOOR � �� 1 -- , AND FURR STRIPS �,; <br /> c, "� I t, PLANS FOR LOCATlONS) , I <br /> 0 0 � , , 5 f � � ; lNSULATE FLOOR �I i� . z s i , 5 � �- <br /> z� f. � " 1' OVER UNHEATED 5 �� ' , �j ; BELLY BAND 3 � �.; <br /> �Q r: , 2 D1 r: SPACE �� � i ' z 2 2 �i i � D1 I <br /> ¢z i I ; , ��FLASHING D3 ;:, I � <br /> � �o � ' 2 4 z 4 � I; ;f' z 4 ' � I T ,E M L i, � s ' � FIN. FLOOR � <br /> a_o ; � � � <br /> �,, ;..........:... .. . .,.... .,..,>.,..... ' N I I I <br /> "'� � z 4 � �4 ;� ;�� � � � � � � � ,. ' ��� 2x10 BELLY — � � � � WALL BATT I SUL. � �c <br /> �� � � � �� � [NSULATE FLOOR � ,i, . � R 0( T ,.� SOLlD RIM BOARD BLOCKING BAND ' � � �---SOLIO RIM BOARD BLOCKING � <br /> � 3%z" ACOUST. I ' ' 2 � � � �' OVER UNH�ATED �: ' � , �� � '� ' 2x10 JOtSTS C� � � _ <br /> SPACE ``: � �' 6 <br /> . . ` <br /> BATT INSUL.—= :; i � � �: '�. �: �� , � I,�:' o ;' 16" O.C. U.N.O. ; -� <br /> f 10 10 1 <br /> � <br /> 2 �'; � 2 2 i �i= 2 �6 ,�' � � <br /> ` _ .. ., , ... <br /> :. I : 4 4 ,� . .,.. . . : .. ,�.,. �� <br /> r �i �, � �. 2_ 6 I — - � � <br /> � . I. : 4 ' 'l ..,� ,:., ..,. ,. .,,... ,�. . :,:-..... .:, .: .....:. .. � 5 � 2x6 TRIM <br /> , � � i� F. z s � � <br /> � t FIRE—SAFING INSUL .,..:. <� �.. . ..... ... . ..:. z a z 4 =- z � �' D1 � 2� 6 � <br /> � <br /> � I I <br /> to 4 �o� , , AS �IREBLOCK, TYP , ' ` ': TYP. I � I � � <br /> �1� : "_ �� 2 4 2 � 4 ,. » �� I Z 4 i � �. 2 6 � c .� <br /> , : ,.. �. , ,� '.. � 2� 4 z � 4 �F r ���� INSULATE FLOOR 5�8 GWB �� � ' o <br /> INSULATE FLOOR '; 2 4 � ��'j,` g 5 „ , � Y :I f �� F�OOR/CEILING �I i OVER UNNEATED ( � NO INSULATION AT v <br /> , � INSULATE FLOOR I �, <br /> OVER UNHEATED I � � I 1 � <br /> OVER UNHEATED TYP. COMMON WALL /a TYPE X GWB SPACE �. , FIBER CEMENT EXTERlOR SPACES UNNEATED SPACES o� <br /> I ' �� � �' `�: NQ ►NSUL. AT GARAGE � ; SOFFIT BOARD _ z 0 <br /> S P A C� �.: � � 1 , ! F I R E B L O C K I N G � 1 I ,x I;.� � „ , I <br /> � , NO INSUL. AT GARAGE r.�', �` ' � � U N I T -� � � VARIES � <br /> NON—BEARING �;; ' r,�;' BEARING r,`, �I ��.`, ,� I <br /> SITUATION SlTUATION � ;j , .� � � REMOVE (NSULATION 1 I I <br /> E � AT UNHEATED SPACES D1 .. <br /> C MM N WALL AT FLQ�R C4MMON WALL ,AT FLOC�R PRC� ECTINC FL��R EXTERIa�. WALL �T FLOQK. � T <br /> C O M I V 1 0 N W A L L A T S T E P P E� F L O O R a � 1 <br /> �8 1�4 1 0 _ b . 2 g � <br /> 1-1/2" = 1'-0" SECTION 1-1/2" = 1'-0�� SECTION 1-1/2" = 1'-0" SEC_TION 1-1/2" = 1'-0" S�C��ON 1-1/2" = 1'-0" SECTION � <br /> EXTEROR WALL � CENTER WALL OVER � LAP OUTER LAYER QF BUILDING PAPER <br /> 2x4 BLOCK BEHIND COMMON PROPERTY LINE � OVER FLASHWG. fNNER LAYER RUNS <br /> � _ ', I WALL—TO—ROOF � f� c� <br /> p1 FLASHING 8 � TUB NAILING FLANGE (� t BENIND SIDING & TRIM r <br /> �, 12 �� � CONT. 5/a" TYPE 'X' GWB -, t I � " Q <br /> t ' � �� � T <br /> - � P AN ROOF)NG OVER � � PRE—INSTALL 5/a" TYPE 'X' GWB STAIR STRWGER ' I � ' � � _� � 8 � SEE DETAILS 7/15 � � o <br /> BEYOND ; � , ,'�.; � : � � METAL FLASHING FOR BELLYBAND <br /> ROOF SHEATHING '� � �� � ■s <br /> , 4 BENlND TUB/SHOWER. I �� , r,; � t� <br /> � J FLASHING DE7AIL � L. <br /> ��INTERIOR � � � - � - EXTERIOR GRADE PLYWD. BEHIND �'.� �'i� r �I� ' I ''' �� I,L <br /> �' � � � � TUB SHOWER UP 70" MINIMUM , , � �,� '' UNIT ' , ( � ( � UNIT "� <br /> 2x BLOCKING � � = <br /> ° � � ' ' ` ABOVE THE DRAIN INLET �/a" GAP BETWEEN + � , � ! � ' <br /> ( , ` �. <br /> .. <br /> � ; STRINGER AND GWB r ' `` �i ., . 2 4 2 4 I �i BEVEL TOP AND 0 >. <br /> , . . . � i :. . .. .........,...: . -., . 5/4 TR1M m <br /> �.. APPROVED � ;' �� ., ; z z z z 2 2 2 2 , BQNDOMOODEG�REES � O � <br /> `s 2 ' TRUSS HANGER PORCN ROOF 5 ' FIRESTOPPING STR}NGER OF NOT : 1 �j a <br /> I �I a <br /> MONO TRUSSES Q� f i MATERIAL LESS THE (2) 2x JOISTS 2 2 M FURR STRIPS <br /> AT 24" O.C. � ' � 4" NOMINAL THICKNESS � \ II ';`' s s s s s s s s 16" O.C. <br /> - �'- � — - <br /> •� : <br /> : 2 4 2 4 ",� .I,;i '.'' ____________ _______ r____ _ <br /> k' � �'i ' <br /> 5/4x3 TRIM Z Z 2 METAL i � �� ; � 1 ALIGN W1TN ADJACENT <br /> s'� ' --------- —�— / PIPE �N�T E! , ( i�i EXTERIOR D1 �� TRIM AT DECKS OR <br /> _z -- — ---- � <br /> 5 Z Z � ,`; CANTILEVERED FLOOR ,� � <br /> s �2 io io � i, r �� UNIT � <br /> D1 ," FIBER—CEMENT SOFFIT ,o ' 4 � " ;,, ' � ���. TYPICAL VERIFY ON ELEVATIONS N '� <br /> I 4 , I ,o ,o <br /> ;' I WITH STRIP VENTWG _ Z 4 2 4 . ........ .......... . .. . . :.. .�.. . ,.:.... � ; I �i�,�:; W 0 � <br /> INTERIOR EXTERIOR > <br /> 2 4 Z 4 ' ' ALL U.N. . <br /> � � �' � 1x3 TRIM AT PERIMETER � � NQ PLUMBlNG IN �� ,'; I �_ li� ��, i TYPICAL EXTERIOR WALL <br /> �� �' OF PORCH CEILING � '�� 8" COMMON WAL � <br /> 2x10 TRIM AT <br /> I <br /> PERIMETER OF PORCH � � <br /> L�W RaOF AT ENTRY TUB/SHt7V�/ER AT COMMUN WALL STAIR STRINGER AT CCJMMC�N WALL COMMON WA�LL AT EXTERIOR WALL TYPIC�L �ELLY �AN� �, <br /> 19 15 11 7 3 <br /> �°° — ��—o°° SECTION 1" = 1�—o�� SECTION 1-1/2�° _ ��—o°° SECTI�N 1-1/2�� = 1�—o�� PLAN 3°° — ��—o°� SECTION � <br /> . � � <br /> EXTEROR WALL � p � <br /> - WALL—TO—ROOF � � Q? � <br /> � ` i E FLASHING CENTER COMMON WALL 4 � ` � ,;y <br /> D1 QVER PROPERTY LINE � � <br /> ROOFING OVER <br /> UNIT UNIT l � � � <br /> I ROOF SNEATHING „ f� � 4 2—HR. COMMON � � W Q �0 � <br /> 12 4 4�� ,� D1 WALL ASSEMBL.Y 1-- '�'F <br /> - ;� 1 CLEAR AIRSPACE „ � � � � <br /> � � ^—� PER PLAN 1 GLEAR . '2 ¢ , Z 4 _ FULLY INSULATE CORNER ` � � � � <br /> , TYP. AIRSPACE : � 2 2 2 z 2.. . . ... .... . . . .....Z. . � j � N G� <br /> IN TERI OR <br /> �� 1 � � <br /> � � � � <br /> 5 )NTERIOR 2x BLKG. & i' ` � ' <br /> WALL STUDS � � <br /> D1 p� ' s e a s e s s <br /> PORCH ROQF - � " <br /> --- -- � � <br /> . I�' 2 --T 16" OC 2x NAlLER - j � � � <br /> MONO TRUSSES �. � ; j D1 � { 2 6 � � Q <br /> � � �� D1 1 �.:.' I � a-' � <br /> » � : UNIT ., , . . ... <br /> . ,. .. . .... . .... ......... ..:. : .. ' , <br /> . <br /> 6 -- 2 AT 24 O.C. . . 2 � ' 2 4 z a ; 2 12 , � TYP. EXTERfOR � 2 . .. , .. 2 , i � G� � <br /> z BEAM PER STRUC. = ' � �� � � ° I EXTERIOR � y <br /> : I , ; <br /> 4 .c i�' :.4......, ..... . ... . . .. �i a � Q WALL _ ► I.'a (�,(( _ <br /> _ .. ._. ...... ..... . .. :.. , i . . I <br /> -� TEM L i � � <br /> �, � <br /> � TRUSS HANGER TYP. INTERIOR + ' ` � � � IN UL ►0 ( �� � <br /> , � <br /> s _z 5�4x3 TRIM ^ �' j '� ,� � °- SIDING OVER (9} LAYER �y � <br /> s� z ` — WALL ' <br /> y <br /> ' PER PLAN � .`; � I TYPE 'X' GYP. SHEATNING 6 6 0 '�"� O <br /> �, ', � �. OVER WOQD SHEATHfNG <br /> PORCH : .:... .... .... ... . . . .,. ... � _ � Q 0. <br /> � FIBER—CEMENT SOFFIT '�; 2 Z Z 2 2 Z � o <br /> �: . , ; � � <br /> I <br /> UNIT , ;, , �� UNIT CENTER WALL OVER ----------------------------- — ! � <br /> j-�—SIDING 1x3 TRIM AT 2x10 TRIM AT 6 8 6 6 6 6 COMMON PROPERTY LINE EXTERIOR SIDING <br /> EXTERIOR � <br /> _ ' OVER EXTR. PERIMETER OF PERIMETER QF ---------------- � & CORNER CONDITION � <br /> WALL SHTG. PORCN CEILING PORCH � PER ELEVATIONS a � <br /> w <br /> o — <br /> LOW IZOQF AT CANTILEVER C�MMON WA�L � INTERIOR WALLS 2-HR CQMM. WALL AT BL.DG. JOG TYPICAL EXTERIOR CORNER = �obNo.: _.���47 <br /> 2 O � � �� � � Sheet No.: <br /> �°° _ ��—o°� SECTION �—,�2zf = ,�—o°� PLAN ,�� _ ��—o�� PLAN 3" = 1�-0°� PLAN o <br /> � � �� <br /> sheet oraer: A � U F R E S D 1 �� <br /> T <br />