i I
<br /> ��-0• 2�_�" 2'-0" � I
<br /> �-`
<br /> —UPPER CABINET L � � STORAGE FACILITIES TO
<br /> UPPER CABINET � COMPLYWITHANSI905.
<br /> NOTE: IN-TUB REMOVABLE
<br /> - — �__� UPPER CABINET � . —FAUCET CONTROLS SEAT NOT REQUIRED FOR PROVIDE SOLID BLOCKING
<br /> -HAND SHOWER WITH 59"MIN.HOSE RESIDENTIAL UNITS PER � BEHIND SHELF&ROD,TYP.
<br /> LOOP PULL - INSTALLED AS PER ANSI A117.1 309. O � R WITH NONPOSITIVE SHUT-OFF , Ar,si�003.>>.z.5.� -
<br /> � LOW AS POSSIBLE _ --LOOP HARDWARE 1 Il G A B B A R. W A T RT E M P�2 0TICAL �i � EXCEPTION 1 14"DEEPADJUSTABLE
<br /> CO � `_° INSTALLED AS LOW AS ~
<br /> P-LAM I � DEGREES F MAX.PER ANSI 607.8 EDGE TRIM AT TOP OF WIRE SHELVES.SHELVES
<br /> I — � �-� FULL CLOSET WIDTH. �
<br /> 1 i� ONE PIECE PLAM TUB �
<br /> `y P-LAM COUNTERTOP `V POSSIBLE COUNTERTOP \ ~ I '+ .I I� �--PROVIDE SOLID BLOCKING BEHIND ALL SURROUND 5'-0"ABOVE TUB
<br /> o - --- CABINET FRONT - MATCH o P-LAM COUNTERTOP a , „ �I : ,T'� I GRAB BARS-TYP. SHOWER CURTAIN ROD
<br /> � � , „ �ADJ. CAB FINISH ' I = � 2-� / 18" P-LAM PIPE �r � �s°VERTICAL CONTROL END WALL
<br /> �
<br /> �p ' " � � c' � ii � GRAB BAR PER ANSI 607.4.2.2 12"HEAD END WALL �/1'-0" 3'
<br /> _ 2�O _� 2-O � ' � � I GRAB BAR PER ANSI 607.4.2.3----�_
<br /> � � �.. ,��-DRAWER - SIZED FOR � � � PROTECTION PANEL �� �'�L��-- -
<br /> -T STRUCT. BRACING AS REQ. ----- - �_ _ _
<br /> N ._._ ._ __ 24"ICONTROL EN D WALL___
<br /> - � �� PLUMB. IN CABINETS - ENTIRE WIDTH OF � GRABBARPERANSI607.4.2.2 I'��I ����PROVIDESOLIDBLOCKING-TYP. �-�- � `r
<br /> � REMOVABLE CABINET -�__ � SINK BASE 3" L �-- � � �
<br /> - 'r �LL.--!/�DOORS & SH ELF : —LOOP PULL � ` � -- —i Z'�- �- _�—SHOWER UNION \I I -�--TWO 24"BACK WALL I v `° S M R Arc h ite cts
<br /> , _,: _.- .� � � � �
<br /> O - O � CO � TOE Hc KNEE I ��� °' m �- GRAB BARS PER ANSI 607.4.2.1 �? I i ' Z
<br /> � -- -� �4�- - TOE & KNEE CLEARANCE � �� - -� 8,� � C -' �� - Z ¢ 117 S. Main St., Suite 400
<br /> N ci � �! N O � � / �,r� CLEARANCE 10" �-0FFSET PRESSURE M i I� i i �--BOTTOM GRAB BAR �' � w
<br /> - � � • �—� � - BALANCED ' i o a
<br /> c� ' {'! CONTINUE FLOORING I NEW PIPING - SEE � I �• - - Seattle WA 98104
<br /> - N � ANTI-SCALD CONTROLS
<br /> � � CENTERED 9"ABOVE TUB v ,
<br /> .— � � -'f - N d� �� � L---------- I
<br /> ���� � FINISH UNDER CABINET ���_� PLUMB. _, � r:____+�CONTINUE FLOOR � �� PERANSI607.5 � -------J \ � '
<br /> �1'-0" FINISH UNDER CAB. �I SPOUT �\ �
<br /> ��-o° ��BATHTUB PH: 206.623.1104
<br /> FX: 206.623.5285
<br /> SECTION C SECTION D SECTION E
<br /> 1 INTERIOR ELEVATION: TYP._KITCHEN CABI_NET SECTIONS - TYPE 'A' CONVERSION _ INTERIOR ELEVATION: TYP. BATHROOM -_BATHT_UB STANDARDS - TYPE 'A'_CONVERSION _ __ _ , ELEVATION: ACCESSIBLE CLOSET TRAILSIDE
<br /> SCALE. 3/8 - 1 0 7 SCALE. 3/8 - 1 -0 11 SCALE. 3/8 - 1 0
<br /> - - - - - - - - - - VILLAGE
<br /> -ACCESSIBLE / 3'-0" I a�-s• I
<br /> LOWER WORKSPACE 2�-�° ��- I,��-�° � � APARTMENTS
<br /> - SEE SECTION C � � � "^A 1300 100TH PLACE S.E.
<br /> NOTE:TOILET MUST BE BOTTOM OF MIRROR
<br /> LOCATED IN SPOT WITH I MAX 40"A.F.F. PER EVERETT, WA 9HZOH
<br /> , / ACCESSIBLE SINK - SIDEANDBACKWALLS. � ANS11003.11.2.3
<br /> ; I 1830- 2� Q ,,3 1�5 � 2130 SEE SECTION E 21� �30 5� �30 30 5 PROVIDE SOLID � �.
<br /> � � � � � / � � K� BALL GRAB BARS i
<br /> � _%______\_ __/____ _�__ � , i ___�' _ __,�____ � � _ � PROVIDE SOLID FAUCET CONTROL SHALL
<br /> i ' � � � �� �-� �� c0 / �0 �' � �'�� 0�� TYP• � BLOCKING � �� COMPLY WITH ANSI 309
<br /> i REAR WALL GRAB
<br /> i � i - � BEHINDALL
<br /> � �`_____ /= _��___ _._______ ____�=_ N _�____ � __l BARS 36"MIN.PER 604.5.2 � I I GRAB BARS- < � LAVATORY H EIGHT
<br /> i � p � � \ ,� TYP CABINET - SEE �� HOOD / FLUSH CONTROLS TO � TYP• � \ 34"MAXIMUM A.F.F.
<br /> U� �0 �0 �� �� � - �0 i' � � '��
<br /> SECTION D COMPLYWITH PERANSI606.3
<br /> � _ , 3'-6"
<br /> ANSI 309. CONTROLS ON � I� � - FIXED SIDE �
<br /> � � � OPEN SIDE OF TOILET�� / �" WALL GRAB 8" I / 'I
<br /> � - !�- � -KNEECLEARANCE � WATER SUPPLY AND
<br /> � � HOOD RANGE - -- �- '�-� �--- % BARPER '
<br /> � - �� - � �� �� FROM FRONT OF � �
<br /> � t� '�t------ ANSI 604.5.1 , / DRAIN INSULATED
<br /> SWITCH J I� � ____��___�� , � �,aVATORY
<br /> `, ,' � ' \ / _- ___ _ �I � Q o 0 0 0 � __ A I . PER ANSI 606.6
<br /> �:- PER NS 306 3 L
<br /> \ .� /�� \ / B� I p � �I I TOILET HEIGHT 15"-19"A.F.F. I � m � I B TP DISPENSER � � � �TOE CLEARANCE � � �
<br /> � " _�____ \ pW / _� 1 � i^� �_ RANGE � REFRIG. PER ANSI 1003.2.4.5— LOCATED 42"MAX. � � � �
<br /> .". � -- �,.� \--�a, FROM REAR WALL " ' i PER ANSI 306.2 � 0 2' -0"
<br /> .' � \� � � � /� N � \ / � "' �� ao AND 18"MIN.A.F.F. + i `"' N �
<br /> I ,�� �� BD1�� �� � —��D9 BD �9 1 � PERANSI604.7 . --t CLR I
<br /> ' \` � � � i I � \ I t� � °' � � - � '
<br /> � - - � . � � 11� � � preservation
<br /> A B / 3��� / I
<br /> �/ �,_6„ /I
<br /> partners
<br /> �I PER A I
<br /> �003.11.2.4. ����lO����l
<br /> L
<br /> INTERIOR ELEVATION: TYP. KITCHEN - 1 & 2-BDRM TYPE 'A' CONVERSION. INTERIOR ELEVATION: TYP. BATHROOM - - TOILET & LAVATORY STANDARDS - TYPE "A" CONVERSION , 21515 hawthorne blvd., suite �25
<br /> 2 SCALE: 3/8" = 1'-0" � $ SCALE: 3/8" = 1'-0" I torrance, ca 90503
<br /> i TOP OF ELECTRICAL RECEPTACLE OR --� y�.,-`$3�7 �—
<br /> SWITCH 46"A.F.F.BEHIND 24"COUNTER ` ' ` � R�GISTERED I
<br /> PER ANSI A308.3.2 �� AR�F'�I��CT
<br /> ' '�. PROVIDE SOLID � PROVIDE SOLID -� �
<br /> 1 � �
<br /> 3 � 1�5�,, 30 i 2��4� 123 `��� BLOCKING BEHIND � BLOCKING BEHIND ALL i __� �'
<br /> � � / � 1�\ � Q� '� 1�\ , TOP OF ELECTRICAL PANELBOARD 48" --� �� / � GRAB BARS -TYP. OO \ - -- OO
<br /> -� - - �----� _ � ," - �_ - �, ALL G RAB BARS- EAN A. KRALIOS
<br /> \ ' D
<br /> _`____ �__ , ' �______� , A.F.F.PER ANsi �oo2.s '-, � i TYP. , , � 5TA7E OF WASHINGTON
<br /> i � �� �,=" i � I ��, � � �:- ;-_--�-�--���-� �-..., ���
<br /> i �� � � ��
<br /> �� i 0 � i . ��,
<br /> -�------�- -�\---/�- I ' ��_ ��__ �� . i� � \� �? r- PROVIDESOLID �-�—~
<br /> p p � TOP OF CONTROLS(SWITCHES, \� / r � I� � � PROVIDE SOLID � r� `
<br /> � D� HOOD �I Y i / �`� �� �% �` , THERMOSTATS,INTERCOMS)MOUNTED �-� / I I i� ��� � BLOCKING �� �� � � BLOCKING
<br /> 3'-fi"A.F.F.UNLESS NOTED OTHERWISE / I I � / � r BEHIND ALL
<br /> � i�/ �� � � �'� � I � GRAB BARS - ` ' �� ��B BARs - REVISIONS/NOTES
<br /> � - ���""�" �
<br /> I � � � o I I � ACCESS � '' v_I TYP.
<br /> � J L---�-- ----- -- , PANEL �P. �----- b �---�- NO DATE DESCRIPTION
<br /> i � BOTTOM OF ELECTRICAL RECEPTACLE � —I `� ��—�l Q r•:_._ - -__�. - �I � I�—�I � ��--�
<br /> — — 0000 O � \ � '_________________' \ �. OUTLETIB"A.F.F.UNLESSOUTLETSERVES \ L--_------_ ------- - ' O 4.0� .16 50% DD SET
<br /> DEDICATED USE(APPLIANCE ETC.)OR — � � � / I I
<br /> � �� � � i � � � i NOTE�oTHERwisE � � � � ��� � ` � � ' � �� � � - 1 6.09.16 100% DD SET
<br /> , � 0``� � � Y � � '� , � 0 � R � � �
<br /> ----- ---- RANGE � --------- � � --- -------- � DW / REFF�IG. — ' \ � ,
<br /> PER ANSI 1002.9 ALL / � , /
<br /> � / � � /� � �� �` �\ /� �\ /� I LIGHTING CONTROLS, i4 �� / � � i/ i i
<br /> B[ �Q B[ �Q g�g 0" ELECTRICALSWITCHES, i � t � ,, 2 7.15.16 HUD Application
<br /> i , ,_/ ENVIRONMENTAL � � \ � � � � � �----
<br /> CONTROLSANDUSER J 3 8.10.16 HUD Application
<br /> A B CONTROLS FOR INTERCOM � � I
<br /> SYSTEMS SHALL COMPLY A B C' � 4 9.09.16 HUD Application
<br /> WITH ANSI 309. ---
<br /> 5 9.09.16 Permit Set
<br /> INTERIOR ELEVATION: TYPICAL UNIT KITCHEN - 1 , 2, & 3-BDRM. ELEVATION: TYPE A RECEPTACLE & CONTROLS INTERIOR ELEVATION: TYP. BATHROOM - 1-BDRM. TYPE "A" CONVERSION
<br /> 3 SCALE: 3/8" = 1'-0" 4 SCALE: 3/8" = 1'-0" " - ' "
<br /> , 9 SCALE: 3/8 - 1 -0
<br /> �Q�i TITLE
<br /> PROVfDE SOLID INTERIOR ELEVATIONS:
<br /> BLOCKING AT ALL UNITS
<br /> GRAB BAR PROVIDE SOLID PROVIDE SOLID
<br /> LOCATIONS PER � �� BLOCKING BEHIND � BLOCKING BEHIND
<br /> � — ANSI A117.1-2009, O � ALL GRAB BARS- ' ALL GRAB BARS- , �
<br /> � � SECTION �� I NP. NP• \� B OC NG OLID
<br /> PROVIDE SOLID
<br /> / ��' / BLOCKING � � /�
<br /> r� 1003.111.2.5.1 � � � � BEHIND ALL GRAB
<br /> �� � ' :4�% , � —�
<br /> � PROVIDE SOLID BEHIND ALL � � <\ r—� BARS -TYP. ,,� I
<br /> \' \` BLOCKING BEHIND ALL , GRAB BARS- L \\ I I � \
<br /> GRAB BARS-TYP. /� � I I � � `I ��� OOOOO
<br /> \ � _ � TYP. f ' � ' ; I I \ -
<br /> ;;G�; '�� � / ACCESS �� I � � Iv �
<br /> ,Y:� :���• �'
<br /> V l � I—— —
<br /> - -�- i ----� ��-- - �
<br /> 1 r —— —
<br /> � 1f —
<br /> � � PANEL —— � � � �_��
<br /> �� ��� �—, �i � � IC�
<br /> �.,�.
<br /> ,,.— v„�. ----� i
<br /> ---- � — ------- - �-----�
<br /> -- -------
<br /> � J SINGLE I I \ L � �
<br /> O � TOWEL BAR ON TYPE I C�•�I � , \�� O /� ��; DRAWN
<br /> Q AUNITS � L------J �� � � �� ; � MD, DLK
<br /> � ,I ; �\� �, - ,� CHECKED DAK
<br /> ' ___�' �` � ~— � -�� ' ISSU E DATE 09.09.16
<br /> �------- -- i � i
<br /> SHOWER APPEARS AT 3-BDRM UNIT q g C p JOB NUMBER
<br /> 16002.00
<br /> SHEET NO.:
<br /> _ A8 . 01
<br /> INTERIOR ELEVATION: TYPICAL UNIT BATHROOM - 1 , 2, & 3-BDRM. ELEVATION ACCESSIBLE TOWEL BAR INTERIOR_ELEVATION: TYP. BATHROOM - 2-BDRM TYPE 'A' CONVERSION
<br /> 5 SCALE: 3/8" = 1'-0" 6 SCALE: 3/8" =1'-0" 1 O SCALE: 3/8" = 1'-0"
<br />
|