Laserfiche WebLink
i I <br /> ��-0• 2�_�" 2'-0" � I <br /> �-` <br /> —UPPER CABINET L � � STORAGE FACILITIES TO <br /> UPPER CABINET � COMPLYWITHANSI905. <br /> NOTE: IN-TUB REMOVABLE <br /> - — �__� UPPER CABINET � . —FAUCET CONTROLS SEAT NOT REQUIRED FOR PROVIDE SOLID BLOCKING <br /> -HAND SHOWER WITH 59"MIN.HOSE RESIDENTIAL UNITS PER � BEHIND SHELF&ROD,TYP. <br /> LOOP PULL - INSTALLED AS PER ANSI A117.1 309. O � R WITH NONPOSITIVE SHUT-OFF , Ar,si�003.>>.z.5.� - <br /> � LOW AS POSSIBLE _ --LOOP HARDWARE 1 Il G A B B A R. W A T RT E M P�2 0TICAL �i � EXCEPTION 1 14"DEEPADJUSTABLE <br /> CO � `_° INSTALLED AS LOW AS ~ <br /> P-LAM I � DEGREES F MAX.PER ANSI 607.8 EDGE TRIM AT TOP OF WIRE SHELVES.SHELVES <br /> I — � �-� FULL CLOSET WIDTH. � <br /> 1 i� ONE PIECE PLAM TUB � <br /> `y P-LAM COUNTERTOP `V POSSIBLE COUNTERTOP \ ~ I '+ .I I� �--PROVIDE SOLID BLOCKING BEHIND ALL SURROUND 5'-0"ABOVE TUB <br /> o - --- CABINET FRONT - MATCH o P-LAM COUNTERTOP a , „ �I : ,T'� I GRAB BARS-TYP. SHOWER CURTAIN ROD <br /> � � , „ �ADJ. CAB FINISH ' I = � 2-� / 18" P-LAM PIPE �r � �s°VERTICAL CONTROL END WALL <br /> � <br /> �p ' " � � c' � ii � GRAB BAR PER ANSI 607.4.2.2 12"HEAD END WALL �/1'-0" 3' <br /> _ 2�O _� 2-O � ' � � I GRAB BAR PER ANSI 607.4.2.3----�_ <br /> � � �.. ,��-DRAWER - SIZED FOR � � � PROTECTION PANEL �� �'�L��-- - <br /> -T STRUCT. BRACING AS REQ. ----- - �_ _ _ <br /> N ._._ ._ __ 24"ICONTROL EN D WALL___ <br /> - � �� PLUMB. IN CABINETS - ENTIRE WIDTH OF � GRABBARPERANSI607.4.2.2 I'��I ����PROVIDESOLIDBLOCKING-TYP. �-�- � `r <br /> � REMOVABLE CABINET -�__ � SINK BASE 3" L �-- � � � <br /> - 'r �LL.--!/�DOORS & SH ELF : —LOOP PULL � ` � -- —i Z'�- �- _�—SHOWER UNION \I I -�--TWO 24"BACK WALL I v `° S M R Arc h ite cts <br /> , _,: _.- .� � � � � <br /> O - O � CO � TOE Hc KNEE I ��� °' m �- GRAB BARS PER ANSI 607.4.2.1 �? I i ' Z <br /> � -- -� �4�- - TOE & KNEE CLEARANCE � �� - -� 8,� � C -' �� - Z ¢ 117 S. Main St., Suite 400 <br /> N ci � �! N O � � / �,r� CLEARANCE 10" �-0FFSET PRESSURE M i I� i i �--BOTTOM GRAB BAR �' � w <br /> - � � • �—� � - BALANCED ' i o a <br /> c� ' {'! CONTINUE FLOORING I NEW PIPING - SEE � I �• - - Seattle WA 98104 <br /> - N � ANTI-SCALD CONTROLS <br /> � � CENTERED 9"ABOVE TUB v , <br /> .— � � -'f - N d� �� � L---------- I <br /> ���� � FINISH UNDER CABINET ���_� PLUMB. _, � r:____+�CONTINUE FLOOR � �� PERANSI607.5 � -------J \ � ' <br /> �1'-0" FINISH UNDER CAB. �I SPOUT �\ � <br /> ��-o° ��BATHTUB PH: 206.623.1104 <br /> FX: 206.623.5285 <br /> SECTION C SECTION D SECTION E <br /> 1 INTERIOR ELEVATION: TYP._KITCHEN CABI_NET SECTIONS - TYPE 'A' CONVERSION _ INTERIOR ELEVATION: TYP. BATHROOM -_BATHT_UB STANDARDS - TYPE 'A'_CONVERSION _ __ _ , ELEVATION: ACCESSIBLE CLOSET TRAILSIDE <br /> SCALE. 3/8 - 1 0 7 SCALE. 3/8 - 1 -0 11 SCALE. 3/8 - 1 0 <br /> - - - - - - - - - - VILLAGE <br /> -ACCESSIBLE / 3'-0" I a�-s• I <br /> LOWER WORKSPACE 2�-�° ��- I,��-�° � � APARTMENTS <br /> - SEE SECTION C � � � "^A 1300 100TH PLACE S.E. <br /> NOTE:TOILET MUST BE BOTTOM OF MIRROR <br /> LOCATED IN SPOT WITH I MAX 40"A.F.F. PER EVERETT, WA 9HZOH <br /> , / ACCESSIBLE SINK - SIDEANDBACKWALLS. � ANS11003.11.2.3 <br /> ; I 1830- 2� Q ,,3 1�5 � 2130 SEE SECTION E 21� �30 5� �30 30 5 PROVIDE SOLID � �. <br /> � � � � � / � � K� BALL GRAB BARS i <br /> � _%______\_ __/____ _�__ � , i ___�' _ __,�____ � � _ � PROVIDE SOLID FAUCET CONTROL SHALL <br /> i ' � � � �� �-� �� c0 / �0 �' � �'�� 0�� TYP• � BLOCKING � �� COMPLY WITH ANSI 309 <br /> i REAR WALL GRAB <br /> i � i - � BEHINDALL <br /> � �`_____ /= _��___ _._______ ____�=_ N _�____ � __l BARS 36"MIN.PER 604.5.2 � I I GRAB BARS- < � LAVATORY H EIGHT <br /> i � p � � \ ,� TYP CABINET - SEE �� HOOD / FLUSH CONTROLS TO � TYP• � \ 34"MAXIMUM A.F.F. <br /> U� �0 �0 �� �� � - �0 i' � � '�� <br /> SECTION D COMPLYWITH PERANSI606.3 <br /> � _ , 3'-6" <br /> ANSI 309. CONTROLS ON � I� � - FIXED SIDE � <br /> � � � OPEN SIDE OF TOILET�� / �" WALL GRAB 8" I / 'I <br /> � - !�- � -KNEECLEARANCE � WATER SUPPLY AND <br /> � � HOOD RANGE - -- �- '�-� �--- % BARPER ' <br /> � - �� - � �� �� FROM FRONT OF � � <br /> � t� '�t------ ANSI 604.5.1 , / DRAIN INSULATED <br /> SWITCH J I� � ____��___�� , � �,aVATORY <br /> `, ,' � ' \ / _- ___ _ �I � Q o 0 0 0 � __ A I . PER ANSI 606.6 <br /> �:- PER NS 306 3 L <br /> \ .� /�� \ / B� I p � �I I TOILET HEIGHT 15"-19"A.F.F. I � m � I B TP DISPENSER � � � �TOE CLEARANCE � � � <br /> � " _�____ \ pW / _� 1 � i^� �_ RANGE � REFRIG. PER ANSI 1003.2.4.5— LOCATED 42"MAX. � � � � <br /> .". � -- �,.� \--�a, FROM REAR WALL " ' i PER ANSI 306.2 � 0 2' -0" <br /> .' � \� � � � /� N � \ / � "' �� ao AND 18"MIN.A.F.F. + i `"' N � <br /> I ,�� �� BD1�� �� � —��D9 BD �9 1 � PERANSI604.7 . --t CLR I <br /> ' \` � � � i I � \ I t� � °' � � - � ' <br /> � - - � . � � 11� � � preservation <br /> A B / 3��� / I <br /> �/ �,_6„ /I <br /> partners <br /> �I PER A I <br /> �003.11.2.4. ����lO����l <br /> L <br /> INTERIOR ELEVATION: TYP. KITCHEN - 1 & 2-BDRM TYPE 'A' CONVERSION. INTERIOR ELEVATION: TYP. BATHROOM - - TOILET & LAVATORY STANDARDS - TYPE "A" CONVERSION , 21515 hawthorne blvd., suite �25 <br /> 2 SCALE: 3/8" = 1'-0" � $ SCALE: 3/8" = 1'-0" I torrance, ca 90503 <br /> i TOP OF ELECTRICAL RECEPTACLE OR --� y�.,-`$3�7 �— <br /> SWITCH 46"A.F.F.BEHIND 24"COUNTER ` ' ` � R�GISTERED I <br /> PER ANSI A308.3.2 �� AR�F'�I��CT <br /> ' '�. PROVIDE SOLID � PROVIDE SOLID -� � <br /> 1 � � <br /> 3 � 1�5�,, 30 i 2��4� 123 `��� BLOCKING BEHIND � BLOCKING BEHIND ALL i __� �' <br /> � � / � 1�\ � Q� '� 1�\ , TOP OF ELECTRICAL PANELBOARD 48" --� �� / � GRAB BARS -TYP. OO \ - -- OO <br /> -� - - �----� _ � ," - �_ - �, ALL G RAB BARS- EAN A. KRALIOS <br /> \ ' D <br /> _`____ �__ , ' �______� , A.F.F.PER ANsi �oo2.s '-, � i TYP. , , � 5TA7E OF WASHINGTON <br /> i � �� �,=" i � I ��, � � �:- ;-_--�-�--���-� �-..., ��� <br /> i �� � � �� <br /> �� i 0 � i . ��, <br /> -�------�- -�\---/�- I ' ��_ ��__ �� . i� � \� �? r- PROVIDESOLID �-�—~ <br /> p p � TOP OF CONTROLS(SWITCHES, \� / r � I� � � PROVIDE SOLID � r� ` <br /> � D� HOOD �I Y i / �`� �� �% �` , THERMOSTATS,INTERCOMS)MOUNTED �-� / I I i� ��� � BLOCKING �� �� � � BLOCKING <br /> 3'-fi"A.F.F.UNLESS NOTED OTHERWISE / I I � / � r BEHIND ALL <br /> � i�/ �� � � �'� � I � GRAB BARS - ` ' �� ��B BARs - REVISIONS/NOTES <br /> � - ���""�" � <br /> I � � � o I I � ACCESS � '' v_I TYP. <br /> � J L---�-- ----- -- , PANEL �P. �----- b �---�- NO DATE DESCRIPTION <br /> i � BOTTOM OF ELECTRICAL RECEPTACLE � —I `� ��—�l Q r•:_._ - -__�. - �I � I�—�I � ��--� <br /> — — 0000 O � \ � '_________________' \ �. OUTLETIB"A.F.F.UNLESSOUTLETSERVES \ L--_------_ ------- - ' O 4.0� .16 50% DD SET <br /> DEDICATED USE(APPLIANCE ETC.)OR — � � � / I I <br /> � �� � � i � � � i NOTE�oTHERwisE � � � � ��� � ` � � ' � �� � � - 1 6.09.16 100% DD SET <br /> , � 0``� � � Y � � '� , � 0 � R � � � <br /> ----- ---- RANGE � --------- � � --- -------- � DW / REFF�IG. — ' \ � , <br /> PER ANSI 1002.9 ALL / � , / <br /> � / � � /� � �� �` �\ /� �\ /� I LIGHTING CONTROLS, i4 �� / � � i/ i i <br /> B[ �Q B[ �Q g�g 0" ELECTRICALSWITCHES, i � t � ,, 2 7.15.16 HUD Application <br /> i , ,_/ ENVIRONMENTAL � � \ � � � � � �---- <br /> CONTROLSANDUSER J 3 8.10.16 HUD Application <br /> A B CONTROLS FOR INTERCOM � � I <br /> SYSTEMS SHALL COMPLY A B C' � 4 9.09.16 HUD Application <br /> WITH ANSI 309. --- <br /> 5 9.09.16 Permit Set <br /> INTERIOR ELEVATION: TYPICAL UNIT KITCHEN - 1 , 2, & 3-BDRM. ELEVATION: TYPE A RECEPTACLE & CONTROLS INTERIOR ELEVATION: TYP. BATHROOM - 1-BDRM. TYPE "A" CONVERSION <br /> 3 SCALE: 3/8" = 1'-0" 4 SCALE: 3/8" = 1'-0" " - ' " <br /> , 9 SCALE: 3/8 - 1 -0 <br /> �Q�i TITLE <br /> PROVfDE SOLID INTERIOR ELEVATIONS: <br /> BLOCKING AT ALL UNITS <br /> GRAB BAR PROVIDE SOLID PROVIDE SOLID <br /> LOCATIONS PER � �� BLOCKING BEHIND � BLOCKING BEHIND <br /> � — ANSI A117.1-2009, O � ALL GRAB BARS- ' ALL GRAB BARS- , � <br /> � � SECTION �� I NP. NP• \� B OC NG OLID <br /> PROVIDE SOLID <br /> / ��' / BLOCKING � � /� <br /> r� 1003.111.2.5.1 � � � � BEHIND ALL GRAB <br /> �� � ' :4�% , � —� <br /> � PROVIDE SOLID BEHIND ALL � � <\ r—� BARS -TYP. ,,� I <br /> \' \` BLOCKING BEHIND ALL , GRAB BARS- L \\ I I � \ <br /> GRAB BARS-TYP. /� � I I � � `I ��� OOOOO <br /> \ � _ � TYP. f ' � ' ; I I \ - <br /> ;;G�; '�� � / ACCESS �� I � � Iv � <br /> ,Y:� :���• �' <br /> V l � I—— — <br /> - -�- i ----� ��-- - � <br /> 1 r —— — <br /> � 1f — <br /> � � PANEL —— � � � �_�� <br /> �� ��� �—, �i � � IC� <br /> �.,�. <br /> ,,.— v„�. ----� i <br /> ---- � — ------- - �-----� <br /> -- ------- <br /> � J SINGLE I I \ L � � <br /> O � TOWEL BAR ON TYPE I C�•�I � , \�� O /� ��; DRAWN <br /> Q AUNITS � L------J �� � � �� ; � MD, DLK <br /> � ,I ; �\� �, - ,� CHECKED DAK <br /> ' ___�' �` � ~— � -�� ' ISSU E DATE 09.09.16 <br /> �------- -- i � i <br /> SHOWER APPEARS AT 3-BDRM UNIT q g C p JOB NUMBER <br /> 16002.00 <br /> SHEET NO.: <br /> _ A8 . 01 <br /> INTERIOR ELEVATION: TYPICAL UNIT BATHROOM - 1 , 2, & 3-BDRM. ELEVATION ACCESSIBLE TOWEL BAR INTERIOR_ELEVATION: TYP. BATHROOM - 2-BDRM TYPE 'A' CONVERSION <br /> 5 SCALE: 3/8" = 1'-0" 6 SCALE: 3/8" =1'-0" 1 O SCALE: 3/8" = 1'-0" <br />