PLUMBING SYMBOLS LEGEND PLUMBING NOTES ABBREVIATIONS <br /> LINETYPE LEGEND PIPE VALVES AND SPECIALTIES 1 . PLUMBING FIXTURES SHALL BE DESIGNED OR EQUIPPED TO MEET ACT ACOUSTICAL CEILING TILE MBH 1000 BRITISH THERMAL UNITS PER HOUR � <br /> FOLLOWING MAXIMUM WATER USE EFFICIENCYSTANDARDS: ADA AMERICANS WITH DISABILITIES ACT MED MEDIUM � <br /> EXISTING A. V1lATER CLOSETS (TANK STYLE OR FLUSH VALVE). 1.1 GPF AD�1 ADJUSTRBLE MEP MECHANICAL, ELECTRICAL, PLUMBING <br /> NEW WORK DARK/HEAW P'1 PLUMBING EQUIPMENT B. SHOWER HEADS 1.75 GPM AFF ABOVE FINISHED FLOOR MEZZ MEZZANINE � <br /> C. RESIDENTIAL LAVATORYFAUCETS. 1.0 GPM AFG ABOVE FINISHED GRADE MIN MINIMUM � � � � <br /> PIPING SYSTEM LABELS � MEDICAL TAG E. KITCHEN SINK FAUCETS 1 .75 GPM ALT ALTERNATE MISC MISCELLANEOUS � � , <br /> ; <br /> SINK AND LAVATORYDRAINS SHALL BE CHROME PLATED 17 GA. BRASS AP ACCESS PANEL <br /> ---�W--- COLDWATER TUBING BYENGINEERED BRASS, DEARBORN BRASS OR BRASSCRAFT. APPROX APPROXIMATE N/A NOTAPPLICABLE 192 Nickerson, Suite #300 <br /> ----HVI�--- HOTWATER PROVIDE INSULATED P-TRAP AND SUPPLYCOVERS (TRUEBROOR EQUAL;M ARCH ARCHITECTURALIARCHITECT NC NORMALLYCLOSED Seattle, Washington 98109 <br /> DETAIL NUMBER AS AIR SEPARATOR NEG NEGATIVE Phone: 206.285.2966 <br /> AT ALL EXPOSED P-TRAPS AND SUPPLIES PER A.D.A. STANDARDS. <br /> (140) ---- HOT WATER (TEMPERATURE) M-� SHEET 2. PLUMBING F15CTURE MOUNTING SHALL COMPLYWITH CONTRACT AUX AUXILIARY NIC NOT IN CONTRACT <br /> --HW�— HOT WATER CIRCULATING DOCUMENTS, ADA, AND WASHINGTON STATE ACCESSIBILITY CODE. NOM NOMINAL � <br /> FLAG NOTE 3. INS�ALL WATER HAMMER ARRESTORS ON HOT & COLD WATER PIPING BFF BELOW FINISHED FLOOR NPC NON-POTABLE COLD WATER <br /> SD-- STORM DRAIN O BFG BELOW FINISHED GRADE NPCW NON POTABLE COLD WATER . <br /> PW�— PUMPED WASTE OF EACH FIXTURE GROUP AND ATALL FIXTURES W/QUICK ACTING VALVES. BHP BRAKE HORSE POWER NPH NON-POTABLE HOT WATER <br /> _ WASTE BURIED � REVISION TAG UNITS SHALL BE ZURN "SHOKTROLL" OR EQUAL. SELECT UNIT SIZE BLDG BUILDING NPHR NON-POTABLE HOT WATER RETURN <br /> --�I-- � ) AND LOCATION PER MANUFACTURERS RECOMMENDATIONS AND IN ACCORD BOP BOTTOM OF PIPE NPT NATIONAL PIPE THREAD <br /> W WASTE (ABOVE GRADE) WITH PDI STANDARD WH-201 . PROVIDE ACCESS PANELS AT ARRESTORS BTU BRITISH THERMAL UNIT NTS NOTTO SCALE <br /> GW GREASE WASTE � PLUMBING RISER N0. ABOVE GWB CEILINGS. ALL ACCESS PANELS AND DOORS SHALL BE BTUH BRITISH THERMAL UNIT PER HOUR <br /> P-1 SHEET ELMDOR FAB. STEEL SLK SERIES OR EQUAL WITH 14 GAUGE DOOR AND OD OUTSIDE DIAMTER/OVERLOW DRAIN <br /> --- V --- VENT FRAME. PROVIDE WITH CYLINDER LOCK, CONTINUOUS PIANO HINGE CA COMBUSTION AIR OFCI OWNER FURNISHED CONTRACTOR INSTALLED <br /> AND PRIME COATED READYFOR PAINTING. CLG CEILING OFOI 4WNER FURNISHED OWNER INSTALLED <br /> RL RAINLEADER 1 SECTION NUMBER 4, COLD VIfATER AND HOT WATER PIPING SHALL BE INSULATED AND ROUTED CMU CONCRETE MASONRYUNIT ORD OVERFLOW ROOF DRAIN 'I'RAILSIDE � <br /> OD — OVERFLOW DRAIN 1 SHEET NUMBER FULL SIZE WITH APPROPRIATE SIZE REDUCTION AT POINT CO CLEANOUT ORL OVERFLOW RAINWATER LEADER VILLAGE � <br /> --- NPW--- NON-POTABLE COLD WATER OF CONNECTION TO FIXTURE. 112" WATER LINE LIMITED TO 10'-0" COND CONDENSATE <br /> DISTANCE FROM FIXTURE. "DEAD-LEGS"' OR "FUTURE" STUBS ON ACTIVE CW COLD WATER �F PRESSURE DIFFERENTIAL APAR'I'MEN'I'S <br /> G OR P NATURAL GAS OR PROPANE POTABLE WATER LINES SHALL BE LIMITED TO 4° TO PREVENT STAGNANT CX CONNECT TO EXISTING <br /> 1300 100TH PLACE S.E. <br /> F � FIRE SERVICE WATER CONDI710NS. PD PLANTER DRAIN; PRESSURE D ROP EVERETT, WA 98208 <br /> PIPEVALVESAND SPECIALTIES �. INSTALL WATER PIPING ON WARM SIDE OF BUILDING INSULATION. SEE dB DECIBEL PERF PERFORATED <br /> — DIRECTION OF FLOW DCVA DOUBLE CHECK VALVE ASSEMBLY PH PHASE <br /> GATE VALVE SPEC. FOR INSULATION SYSTEMS. SEE DWGS. FOR ELEC. HEATTRACE <br /> CA � COMPRESSED AIR � � REQUIREMENTS. SEE PLUMBING DETAILS FOR PIPE HANGER STYLE. DDCV DOUBLE DETECTOR CHECK VALVE PIV POST INDICATOR VALVE <br /> �-.r—� GLOBEVALVE SEE SPEC. FORHANGERSPACING. DDCVA DOUBLE DETECTORCHECKVAVLE ASSEMBLY PLBG PLUMBING <br /> DI --� DIONIZED WATER - <br /> —�--� NON RISING STEM VA�VE 6. WHEN CONNECTING TO EXISTING BURIED WA.STE PIPING VERIF�f PROPER QF DRINKING FOUNTAIN PRESS PRESSURE <br /> V --� VACUUM —��— RISING STEM GATE VALVE FLOW GONDITIONS BEFORE COVERING. BURIED WASTE & VENT PIPING DFU DRAINAGE FIXTURE UNIT PRV PRESSURE REDUCING VALVE <br /> SHALL BE MIN. 2" DIA. & SLOPED 114"/FT. UNLESS OTHERWISE NOTED. DHW DOMESTIC HOT WATER PSF POUNDS PER SQUARE FOOT <br /> � C � CONDENSATE �--� BALANCING VALVE (CIRCUIT SETTER) ' DHWC DOMESTIC HOT WATER RECIRCULATION PSI POUNDS PER SQUARE INCH <br /> PVC OR ABS PIPING SHALL BE USED ONLYIF APPROVED BY � OR DIA DIAMETER PSIG POUNDS P�R INCH GAUGE <br /> PC � PUMPED CONDENSATE ��r----� AUTOFLOW VALVE ADMINISTRATIVE AUTHORITY, SEE SPECIFICATIONS FOR FURTHER WFO. pN DOWN <br /> 7. PROVIDE TRAP PRIMERS ON ALL FLOOR DRAINS EXCEPT IN SHOWER <br /> � X�� SLOPE SYMBOL �---� CHECKVALVE DWG�S) DRAWING�S} QTY QUANTITY <br /> (X' PER FOOT) r� STALLS OR OTHERWISE NOTED ON DWGS. CONTRACTOR SHALL INSTALL DWV DRAIN, WASTE, VENT <br /> —�UI--� SALL VALVE ACCESS PANELS WHERE PRIMERS ARE CONCEALED IN WALLS. RD ROOF DRAIN ' <br /> a 8. COORDINATE VENT THROUGH ROOF (VTR} LOCATIONS WITH HVAC UNITS. preSel�VC�tIOI1 <br /> PIPE FITTINGS �D�—• PRESSURE REDUCING VALVE EA EACH REQD REQUIRED <br /> MAINTAIN MIN. 10'-0" CLEARANCE. OFFSETVTRAS NECESSARY. EEW EMERGENCYEYEV�/ASH RL RAIN WATER LEADER pal lnerS � <br /> � PIPE DOWN �� COORDINATE PIPE ROUTING WITH HVAC AND SPRINKLER CONTRACTORS. EFF EFFICIENCY RM ROOM � <br /> - PRESSURE GAUGE 9. SITE WATER PRESSURE IS 70 PSI PER CITYOF EVERETTWATER DEPT. ELEV ELEVATION RPBP REDUCED PRESSURE BACKFLOW PREVENTER development <br /> —Q PIPE UP 10. RISER DIAGRAMS & PLANS DO NOT SHOW SOME PIPING OFFSETS REQUIRED EQUIP EQUIPMENT RPM REVOLUTIONS PER MINUTE ' � <br /> —�--- TEE UP THERMOMETER FOR STRUCTURAL CLEARANCES. EXACT ROUTING MAYVARYFR�M THAT ES EMERGENCYSHQWER RLX RELOCATE EXISTING 21515 hawthorne blvd., suite 125 <br /> ` � STRAINER INDICATED. ALL WASTE PIPING INCLUDING RISERS ON RESIDENTIAL ET EXPANSION TANK RV RELIEF VALVE torrance, ca 90503 <br /> � TEE DOWN LEVELS TO BE CAST IRON. EX EXISTING/EXISTING TO REMAIN RX REMOVE EXISTING <br /> _��I�-- UNION � SAFETYVALVE 11. PROVIDE ELECTRIC HEAT TRACE UNDER PIPING INSULATION FOR ALL WATER EXP EXPANSIQN <br /> , PIPING INSTALLED IN UNHEATED GARAGE SPACES. S SINK .�.BER�y, <br /> _� 12. CONFIGURE PIPING FOR SUDS RELIEF AS REQUIRED BYTHE UPC. FC FAIL CLOSED S STORM 4,,�' F s 1�,�; <br /> PIPE ANCHOR POINT �, � <br /> PIPING FLEXIBLE CONNECTIONS FCO FLOOR GLEANOUT SCFM STANDARD CUBIC FEET PER MINUT � ' �',�'�' <br /> 13. ALL LEVER CONTROLLED WATER CLOSETS TO BE INS7ALLED WITH � <br /> � PIPE GUIDE THE LEVER ON THE OPEN SIDE OF THE BATHROOM. FD FLOOR DRAIN SD STORM DRAIN � - <br /> —JI�1-- BUTTERF�YVALVE FD� FIRE DEPARTMENTCONNECTION SF SQUARE FOOT <br /> FF FINISHED FLOOR SFU SUPPLYFIXTURE UNIT �'�°�,� �,��1�w� <br /> ---I }--- FLANGE � <br /> —� I OR ] CAP FLA FULL LOAD AMPS SH SHOWER SSIONAL � <br /> _ .- - ] CAP <br /> - ENERGY CODE NOTES <br /> FM FORCE MAIN S.O.V. SHUTOFF VALVE <br /> —� HOSE BIBB 1 . SEE SCHEDULE FOR WATER HEATER EQUIPMENT TYPE, CAPACITYAND FO FAIL OPEN SPEC SPECIFICATION REVISIONS/NOTES <br /> EFFICIENCY FP FIRE PROTECTION S/S, OR SS STAINLESS STEEL <br /> DOUBLE CHECK VALVE 2. PUBLIC LAVATORIES SHALL BE EQUIPPED WITH AN ASSE 1070 MIXING VALVE FPM FEET PER MINUTE STD STANDARD �Q DATE DESCRIPTION— <br /> DRAINS AND CLEANOUTS FPS FEET PER SECOND SYM SYMBOL <br /> SET TO DELIVERY 110 F HOT WATER. 3.11.16 PROGRESS <br /> � FLOOR SINK RPBA 3. NONCIRCULATING HOT WATER SYSTEMS WIHOUT AN INTEGRAL HEAT TRAP FS FLOOR SINK = <br /> SHALL BE PROVIDED WITH HEAT TRAPS ON THE SUPPLYAND DISCHARGE FSZV FIRE SPRINKLER ZONE VALVE ASSEMBLY T&P TEMPER,�TURE AND PRESSURE RELIEF VALVE 4.1.16 50% DD <br /> � FLOOR DRAIN -- � TRIPLE DUTYVA�VE PIPING. FT FEETlFOOT TBD TO BE DETERMINED _ 5.20.16 DD _ <br /> 4. ELECTRIC WATER HEATERS IN UNCONDITIONED SPACES OR ON CONCRETE FTG FOOTING TD TRENCH DRAIN _ 7.15.16 HUD APPLICATION � <br /> � HIDDEN FLOOR DRAIN r FLOORS SHALL BE PLACED ON INCOMPRESSIBLE R-10 INSULATION. FV FLUSH VALVE TEMP TEMPERATURE <br /> —�UI--- BALL VALVE MANUAL LEVER 5. PROVIDE PIPE INSULATION PER ENERGYCODE SECTION C404.6 AND TOB TOP OF BEAM 2 8.10.16 HUD APPLICATION <br /> ... — <br /> (�) ROOF DRAIN _���__ BUTTERFLY VALVE SPECIFICATION SECTION 22 07 00. G NATURAL GAS TOC TOP OF CONCRETE _ <br /> MANUAL LEVER 6. INSULATION EXPOSED TO WEATHER SHALL BE PROTECTED FROM DAMAGE, GA GAUGE TOD TOP OF DECK <br /> (Q) OVERFLOW DRAIN SUNLIGHT, MOISTURE AND WIND. ADHESNE TAPE IS NOT PERMITTED. GAL GALLON TOJ TOP OF JOIST <br /> ., — <br /> O FLOOR CLEANOUT —� �— BUTTERFLY GEAR VALVE 7. ALL PIPE AND WRAP INSULATION SHALL BE LABELED WITH ITS THICKNESS AND G.C. GENERAL CONTRACTOR TOS TOP OF SLABITOP OF STEEL _ <br /> INSULATING VALUE (R OR K). GCO GRADE CLEANOUT TP TRAP PRIMER <br /> OO GRADE CLEANOUT —p� GLOBE VALVE MANUAL LEVER $. CIRCULATING HOT WATER PUMPS OR HEAT TRACE SHALL BE EQUIPPED WITH GD GARAGE DRAIN T&P TEMPERATURE & PRESSURE — � <br /> AUTOMATIC TIMERS. GPF GALLONS PER FLUSH TYP TYPICAL — <br /> TRENCH DRAIN ,u, BALANCE VA�VE GPH GALLONS PER HOUR <br /> (PRESSURE INDEPENDENT) GPM GALLONS PER MINUTE UL UNDERWRITERS LABORATORY TITLE � <br /> � WALL CLEANOUT GW GREASE WASTE UNO UNLESS NOTED OTHERWISE COVER SHEET <br /> UP TO CLEANOUT � PUMP <br /> � UR URINAL <br /> H HEIGHT <br /> � FUNNEL DRAIN � METER HB HOSE BIBB V VENT(S) <br /> HBVB HOSE BIBB VACUUM BREAKER V VOLT <br /> O METER HD HEAD VERT VERTICAL <br /> HP HORSEPOWER VFD VARIABLE FREQUENCY DRIVE - <br /> STANDPIPE HS HAND SINK VIB VALVE-IN-BOX <br /> FUNNEL DRAIN HW HOT WATER VTR VENTTHROUGH ROOF MUP # <br /> HX HEATEXCHANGER <br /> PERMIT# <br /> Y W WASTEIWATER SDOT# <br /> I IE INVERT ELEVATION W/ WITH DI�AWN <br /> IN INCHIINCHES W/IN �'lflTHIN KS <br /> W/O WITHOUT CHECKED DF <br /> KW KILO�IVATTIKILOWATTS WC WATER CLOSET <br /> W�O WALL CLEANOUT ISSUE DATE 08.12 16 <br /> LAV LAVATORY WH WATER HEATER JOB NUMBER <br /> 16011 � <br /> LBS POUNDS WPD WATER PRESSURE DROP SHEET NO.: <br /> LF LINEAL FOOT WT WEIGHT . <br /> LTG LIGHTING P � . O � <br /> LV1/T LEAVING WATER TEMPERATURE YCO YARD CLEANOUT <br />