My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1306 100TH PL SE 2016 Plans 2022-12-02
>
Address Records
>
100TH PL SE
>
1306
>
Plans
>
1306 100TH PL SE 2016 Plans 2022-12-02
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/2/2022 9:23:21 AM
Creation date
10/23/2018 1:30:39 PM
Metadata
Fields
Template:
Address Document
Street Name
100TH PL SE
Street Number
1306
Permit
B1609-033-056
Year
2016
Notes
TRAILSIDE VILLAGE APARTMENTS INTERIOR AND EXTERIOR RENOVATIONS
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
114
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
PLUMBING SYMBOLS LEGEND PLUMBING NOTES ABBREVIATIONS <br /> LINETYPE LEGEND PIPE VALVES AND SPECIALTIES 1 . PLUMBING FIXTURES SHALL BE DESIGNED OR EQUIPPED TO MEET ACT ACOUSTICAL CEILING TILE MBH 1000 BRITISH THERMAL UNITS PER HOUR � <br /> FOLLOWING MAXIMUM WATER USE EFFICIENCYSTANDARDS: ADA AMERICANS WITH DISABILITIES ACT MED MEDIUM � <br /> EXISTING A. V1lATER CLOSETS (TANK STYLE OR FLUSH VALVE). 1.1 GPF AD�1 ADJUSTRBLE MEP MECHANICAL, ELECTRICAL, PLUMBING <br /> NEW WORK DARK/HEAW P'1 PLUMBING EQUIPMENT B. SHOWER HEADS 1.75 GPM AFF ABOVE FINISHED FLOOR MEZZ MEZZANINE � <br /> C. RESIDENTIAL LAVATORYFAUCETS. 1.0 GPM AFG ABOVE FINISHED GRADE MIN MINIMUM � � � � <br /> PIPING SYSTEM LABELS � MEDICAL TAG E. KITCHEN SINK FAUCETS 1 .75 GPM ALT ALTERNATE MISC MISCELLANEOUS � � , <br /> ; <br /> SINK AND LAVATORYDRAINS SHALL BE CHROME PLATED 17 GA. BRASS AP ACCESS PANEL <br /> ---�W--- COLDWATER TUBING BYENGINEERED BRASS, DEARBORN BRASS OR BRASSCRAFT. APPROX APPROXIMATE N/A NOTAPPLICABLE 192 Nickerson, Suite #300 <br /> ----HVI�--- HOTWATER PROVIDE INSULATED P-TRAP AND SUPPLYCOVERS (TRUEBROOR EQUAL;M ARCH ARCHITECTURALIARCHITECT NC NORMALLYCLOSED Seattle, Washington 98109 <br /> DETAIL NUMBER AS AIR SEPARATOR NEG NEGATIVE Phone: 206.285.2966 <br /> AT ALL EXPOSED P-TRAPS AND SUPPLIES PER A.D.A. STANDARDS. <br /> (140) ---- HOT WATER (TEMPERATURE) M-� SHEET 2. PLUMBING F15CTURE MOUNTING SHALL COMPLYWITH CONTRACT AUX AUXILIARY NIC NOT IN CONTRACT <br /> --HW�— HOT WATER CIRCULATING DOCUMENTS, ADA, AND WASHINGTON STATE ACCESSIBILITY CODE. NOM NOMINAL � <br /> FLAG NOTE 3. INS�ALL WATER HAMMER ARRESTORS ON HOT & COLD WATER PIPING BFF BELOW FINISHED FLOOR NPC NON-POTABLE COLD WATER <br /> SD-- STORM DRAIN O BFG BELOW FINISHED GRADE NPCW NON POTABLE COLD WATER . <br /> PW�— PUMPED WASTE OF EACH FIXTURE GROUP AND ATALL FIXTURES W/QUICK ACTING VALVES. BHP BRAKE HORSE POWER NPH NON-POTABLE HOT WATER <br /> _ WASTE BURIED � REVISION TAG UNITS SHALL BE ZURN "SHOKTROLL" OR EQUAL. SELECT UNIT SIZE BLDG BUILDING NPHR NON-POTABLE HOT WATER RETURN <br /> --�I-- � ) AND LOCATION PER MANUFACTURERS RECOMMENDATIONS AND IN ACCORD BOP BOTTOM OF PIPE NPT NATIONAL PIPE THREAD <br /> W WASTE (ABOVE GRADE) WITH PDI STANDARD WH-201 . PROVIDE ACCESS PANELS AT ARRESTORS BTU BRITISH THERMAL UNIT NTS NOTTO SCALE <br /> GW GREASE WASTE � PLUMBING RISER N0. ABOVE GWB CEILINGS. ALL ACCESS PANELS AND DOORS SHALL BE BTUH BRITISH THERMAL UNIT PER HOUR <br /> P-1 SHEET ELMDOR FAB. STEEL SLK SERIES OR EQUAL WITH 14 GAUGE DOOR AND OD OUTSIDE DIAMTER/OVERLOW DRAIN <br /> --- V --- VENT FRAME. PROVIDE WITH CYLINDER LOCK, CONTINUOUS PIANO HINGE CA COMBUSTION AIR OFCI OWNER FURNISHED CONTRACTOR INSTALLED <br /> AND PRIME COATED READYFOR PAINTING. CLG CEILING OFOI 4WNER FURNISHED OWNER INSTALLED <br /> RL RAINLEADER 1 SECTION NUMBER 4, COLD VIfATER AND HOT WATER PIPING SHALL BE INSULATED AND ROUTED CMU CONCRETE MASONRYUNIT ORD OVERFLOW ROOF DRAIN 'I'RAILSIDE � <br /> OD — OVERFLOW DRAIN 1 SHEET NUMBER FULL SIZE WITH APPROPRIATE SIZE REDUCTION AT POINT CO CLEANOUT ORL OVERFLOW RAINWATER LEADER VILLAGE � <br /> --- NPW--- NON-POTABLE COLD WATER OF CONNECTION TO FIXTURE. 112" WATER LINE LIMITED TO 10'-0" COND CONDENSATE <br /> DISTANCE FROM FIXTURE. "DEAD-LEGS"' OR "FUTURE" STUBS ON ACTIVE CW COLD WATER �F PRESSURE DIFFERENTIAL APAR'I'MEN'I'S <br /> G OR P NATURAL GAS OR PROPANE POTABLE WATER LINES SHALL BE LIMITED TO 4° TO PREVENT STAGNANT CX CONNECT TO EXISTING <br /> 1300 100TH PLACE S.E. <br /> F � FIRE SERVICE WATER CONDI710NS. PD PLANTER DRAIN; PRESSURE D ROP EVERETT, WA 98208 <br /> PIPEVALVESAND SPECIALTIES �. INSTALL WATER PIPING ON WARM SIDE OF BUILDING INSULATION. SEE dB DECIBEL PERF PERFORATED <br /> — DIRECTION OF FLOW DCVA DOUBLE CHECK VALVE ASSEMBLY PH PHASE <br /> GATE VALVE SPEC. FOR INSULATION SYSTEMS. SEE DWGS. FOR ELEC. HEATTRACE <br /> CA � COMPRESSED AIR � � REQUIREMENTS. SEE PLUMBING DETAILS FOR PIPE HANGER STYLE. DDCV DOUBLE DETECTOR CHECK VALVE PIV POST INDICATOR VALVE <br /> �-.r—� GLOBEVALVE SEE SPEC. FORHANGERSPACING. DDCVA DOUBLE DETECTORCHECKVAVLE ASSEMBLY PLBG PLUMBING <br /> DI --� DIONIZED WATER - <br /> —�--� NON RISING STEM VA�VE 6. WHEN CONNECTING TO EXISTING BURIED WA.STE PIPING VERIF�f PROPER QF DRINKING FOUNTAIN PRESS PRESSURE <br /> V --� VACUUM —��— RISING STEM GATE VALVE FLOW GONDITIONS BEFORE COVERING. BURIED WASTE & VENT PIPING DFU DRAINAGE FIXTURE UNIT PRV PRESSURE REDUCING VALVE <br /> SHALL BE MIN. 2" DIA. & SLOPED 114"/FT. UNLESS OTHERWISE NOTED. DHW DOMESTIC HOT WATER PSF POUNDS PER SQUARE FOOT <br /> � C � CONDENSATE �--� BALANCING VALVE (CIRCUIT SETTER) ' DHWC DOMESTIC HOT WATER RECIRCULATION PSI POUNDS PER SQUARE INCH <br /> PVC OR ABS PIPING SHALL BE USED ONLYIF APPROVED BY � OR DIA DIAMETER PSIG POUNDS P�R INCH GAUGE <br /> PC � PUMPED CONDENSATE ��r----� AUTOFLOW VALVE ADMINISTRATIVE AUTHORITY, SEE SPECIFICATIONS FOR FURTHER WFO. pN DOWN <br /> 7. PROVIDE TRAP PRIMERS ON ALL FLOOR DRAINS EXCEPT IN SHOWER <br /> � X�� SLOPE SYMBOL �---� CHECKVALVE DWG�S) DRAWING�S} QTY QUANTITY <br /> (X' PER FOOT) r� STALLS OR OTHERWISE NOTED ON DWGS. CONTRACTOR SHALL INSTALL DWV DRAIN, WASTE, VENT <br /> —�UI--� SALL VALVE ACCESS PANELS WHERE PRIMERS ARE CONCEALED IN WALLS. RD ROOF DRAIN ' <br /> a 8. COORDINATE VENT THROUGH ROOF (VTR} LOCATIONS WITH HVAC UNITS. preSel�VC�tIOI1 <br /> PIPE FITTINGS �D�—• PRESSURE REDUCING VALVE EA EACH REQD REQUIRED <br /> MAINTAIN MIN. 10'-0" CLEARANCE. OFFSETVTRAS NECESSARY. EEW EMERGENCYEYEV�/ASH RL RAIN WATER LEADER pal lnerS � <br /> � PIPE DOWN �� COORDINATE PIPE ROUTING WITH HVAC AND SPRINKLER CONTRACTORS. EFF EFFICIENCY RM ROOM � <br /> - PRESSURE GAUGE 9. SITE WATER PRESSURE IS 70 PSI PER CITYOF EVERETTWATER DEPT. ELEV ELEVATION RPBP REDUCED PRESSURE BACKFLOW PREVENTER development <br /> —Q PIPE UP 10. RISER DIAGRAMS & PLANS DO NOT SHOW SOME PIPING OFFSETS REQUIRED EQUIP EQUIPMENT RPM REVOLUTIONS PER MINUTE ' � <br /> —�--- TEE UP THERMOMETER FOR STRUCTURAL CLEARANCES. EXACT ROUTING MAYVARYFR�M THAT ES EMERGENCYSHQWER RLX RELOCATE EXISTING 21515 hawthorne blvd., suite 125 <br /> ` � STRAINER INDICATED. ALL WASTE PIPING INCLUDING RISERS ON RESIDENTIAL ET EXPANSION TANK RV RELIEF VALVE torrance, ca 90503 <br /> � TEE DOWN LEVELS TO BE CAST IRON. EX EXISTING/EXISTING TO REMAIN RX REMOVE EXISTING <br /> _��I�-- UNION � SAFETYVALVE 11. PROVIDE ELECTRIC HEAT TRACE UNDER PIPING INSULATION FOR ALL WATER EXP EXPANSIQN <br /> , PIPING INSTALLED IN UNHEATED GARAGE SPACES. S SINK .�.BER�y, <br /> _� 12. CONFIGURE PIPING FOR SUDS RELIEF AS REQUIRED BYTHE UPC. FC FAIL CLOSED S STORM 4,,�' F s 1�,�; <br /> PIPE ANCHOR POINT �, � <br /> PIPING FLEXIBLE CONNECTIONS FCO FLOOR GLEANOUT SCFM STANDARD CUBIC FEET PER MINUT � ' �',�'�' <br /> 13. ALL LEVER CONTROLLED WATER CLOSETS TO BE INS7ALLED WITH � <br /> � PIPE GUIDE THE LEVER ON THE OPEN SIDE OF THE BATHROOM. FD FLOOR DRAIN SD STORM DRAIN � - <br /> —JI�1-- BUTTERF�YVALVE FD� FIRE DEPARTMENTCONNECTION SF SQUARE FOOT <br /> FF FINISHED FLOOR SFU SUPPLYFIXTURE UNIT �'�°�,� �,��1�w� <br /> ---I }--- FLANGE � <br /> —� I OR ] CAP FLA FULL LOAD AMPS SH SHOWER SSIONAL � <br /> _ .- - ] CAP <br /> - ENERGY CODE NOTES <br /> FM FORCE MAIN S.O.V. SHUTOFF VALVE <br /> —� HOSE BIBB 1 . SEE SCHEDULE FOR WATER HEATER EQUIPMENT TYPE, CAPACITYAND FO FAIL OPEN SPEC SPECIFICATION REVISIONS/NOTES <br /> EFFICIENCY FP FIRE PROTECTION S/S, OR SS STAINLESS STEEL <br /> DOUBLE CHECK VALVE 2. PUBLIC LAVATORIES SHALL BE EQUIPPED WITH AN ASSE 1070 MIXING VALVE FPM FEET PER MINUTE STD STANDARD �Q DATE DESCRIPTION— <br /> DRAINS AND CLEANOUTS FPS FEET PER SECOND SYM SYMBOL <br /> SET TO DELIVERY 110 F HOT WATER. 3.11.16 PROGRESS <br /> � FLOOR SINK RPBA 3. NONCIRCULATING HOT WATER SYSTEMS WIHOUT AN INTEGRAL HEAT TRAP FS FLOOR SINK = <br /> SHALL BE PROVIDED WITH HEAT TRAPS ON THE SUPPLYAND DISCHARGE FSZV FIRE SPRINKLER ZONE VALVE ASSEMBLY T&P TEMPER,�TURE AND PRESSURE RELIEF VALVE 4.1.16 50% DD <br /> � FLOOR DRAIN -- � TRIPLE DUTYVA�VE PIPING. FT FEETlFOOT TBD TO BE DETERMINED _ 5.20.16 DD _ <br /> 4. ELECTRIC WATER HEATERS IN UNCONDITIONED SPACES OR ON CONCRETE FTG FOOTING TD TRENCH DRAIN _ 7.15.16 HUD APPLICATION � <br /> � HIDDEN FLOOR DRAIN r FLOORS SHALL BE PLACED ON INCOMPRESSIBLE R-10 INSULATION. FV FLUSH VALVE TEMP TEMPERATURE <br /> —�UI--- BALL VALVE MANUAL LEVER 5. PROVIDE PIPE INSULATION PER ENERGYCODE SECTION C404.6 AND TOB TOP OF BEAM 2 8.10.16 HUD APPLICATION <br /> ... — <br /> (�) ROOF DRAIN _���__ BUTTERFLY VALVE SPECIFICATION SECTION 22 07 00. G NATURAL GAS TOC TOP OF CONCRETE _ <br /> MANUAL LEVER 6. INSULATION EXPOSED TO WEATHER SHALL BE PROTECTED FROM DAMAGE, GA GAUGE TOD TOP OF DECK <br /> (Q) OVERFLOW DRAIN SUNLIGHT, MOISTURE AND WIND. ADHESNE TAPE IS NOT PERMITTED. GAL GALLON TOJ TOP OF JOIST <br /> ., — <br /> O FLOOR CLEANOUT —� �— BUTTERFLY GEAR VALVE 7. ALL PIPE AND WRAP INSULATION SHALL BE LABELED WITH ITS THICKNESS AND G.C. GENERAL CONTRACTOR TOS TOP OF SLABITOP OF STEEL _ <br /> INSULATING VALUE (R OR K). GCO GRADE CLEANOUT TP TRAP PRIMER <br /> OO GRADE CLEANOUT —p� GLOBE VALVE MANUAL LEVER $. CIRCULATING HOT WATER PUMPS OR HEAT TRACE SHALL BE EQUIPPED WITH GD GARAGE DRAIN T&P TEMPERATURE & PRESSURE — � <br /> AUTOMATIC TIMERS. GPF GALLONS PER FLUSH TYP TYPICAL — <br /> TRENCH DRAIN ,u, BALANCE VA�VE GPH GALLONS PER HOUR <br /> (PRESSURE INDEPENDENT) GPM GALLONS PER MINUTE UL UNDERWRITERS LABORATORY TITLE � <br /> � WALL CLEANOUT GW GREASE WASTE UNO UNLESS NOTED OTHERWISE COVER SHEET <br /> UP TO CLEANOUT � PUMP <br /> � UR URINAL <br /> H HEIGHT <br /> � FUNNEL DRAIN � METER HB HOSE BIBB V VENT(S) <br /> HBVB HOSE BIBB VACUUM BREAKER V VOLT <br /> O METER HD HEAD VERT VERTICAL <br /> HP HORSEPOWER VFD VARIABLE FREQUENCY DRIVE - <br /> STANDPIPE HS HAND SINK VIB VALVE-IN-BOX <br /> FUNNEL DRAIN HW HOT WATER VTR VENTTHROUGH ROOF MUP # <br /> HX HEATEXCHANGER <br /> PERMIT# <br /> Y W WASTEIWATER SDOT# <br /> I IE INVERT ELEVATION W/ WITH DI�AWN <br /> IN INCHIINCHES W/IN �'lflTHIN KS <br /> W/O WITHOUT CHECKED DF <br /> KW KILO�IVATTIKILOWATTS WC WATER CLOSET <br /> W�O WALL CLEANOUT ISSUE DATE 08.12 16 <br /> LAV LAVATORY WH WATER HEATER JOB NUMBER <br /> 16011 � <br /> LBS POUNDS WPD WATER PRESSURE DROP SHEET NO.: <br /> LF LINEAL FOOT WT WEIGHT . <br /> LTG LIGHTING P � . O � <br /> LV1/T LEAVING WATER TEMPERATURE YCO YARD CLEANOUT <br />
The URL can be used to link to this page
Your browser does not support the video tag.