My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
9720 EVERGREEN WAY BOYS AND GIRLS CLUB 2018-01-01 MF Import
>
Address Records
>
EVERGREEN WAY
>
9720
>
BOYS AND GIRLS CLUB
>
9720 EVERGREEN WAY BOYS AND GIRLS CLUB 2018-01-01 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/30/2018 11:35:32 AM
Creation date
10/30/2018 11:35:24 AM
Metadata
Fields
Template:
Address Document
Street Name
EVERGREEN WAY
Street Number
9720
Tenant Name
BOYS AND GIRLS CLUB
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
46
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
. <br />.• <br />� <br />April 19, 1965 <br />DON UGLEM <br />SNO CO BOYS CLUB <br />PO 6�X 5224 <br />EVERETT� WA 98206 <br />Dear Mr. Uglem: <br />� <br />r'�.i <br />,,,; � <br />RE: NEW OCCUPAi�CY INSPECTION OF BINGO HALL AT 9700 EVERGREEN WAY <br />0108i <br />���[�0�11�':a <br />APR � ; 1985 <br />CITY OF EVERETi' <br />Pi:t'ic Works Dep;. <br />Gn OF <br />everett <br />zs: i onKes • z:3�a�a� <br />EVERETT.Y!?SH�r,GiON <br />9�i01 <br />ciae oFa«-vn:r <br />An inspection performed on t}:is date has brought the Fire Prevention Bureau to <br />the Eollowin9 conclusions: <br />1. This occupancy as presently constructed cannot be approved for permanent <br />occupancy Eor the following reasons: <br />A. The Uniform Buildin� Code, 1982 edition, as adopted by the State of <br />Washington, and enforced by the City of Everett, prohibits a Group <br />A-2.1 occupancy being located in a construction type V-N building. <br />The grau�i classification of use is 6etermined by the assigned <br />Occupant Load which in turn is determined by the total square <br />footage dedicated to such use. <br />One solution to this problem would be construction oE a fire rated <br />two-hour area separation wall. Such a wall would divide the <br />existing total area into two separate areas, each of which would be <br />belov the 6,000 square foot maximum allo:�ed by the Code. <br />Alternative methods may be used upo� approval of the Fire ChieE and <br />the Building OfEicial. <br />B. There are no existing fire-rated one hour occupancy separation walls <br />where this occupancy is exposed to the business occupancies at both <br />ends of the building. <br />C. The storage areas have not been prooerly separated. Here again, a <br />one-hour rating is required. <br />
The URL can be used to link to this page
Your browser does not support the video tag.