Laserfiche WebLink
_ , �. <br /> E1 UNIT VARIATIONS <br /> A - SINGLE PORCH/ NQ POPOUT AT REAR ���_q,�� 15'-4" <br /> B - SINGLE PORCN/ POPOUT AT REAR � n � ,: � ,� � � � » � , i ' : <br /> i1'-5� 4'-3�y 4�-314 5-4' � � -��, 4�-3�4 4�-3�4- , 5'-4' � , <br /> : > . <br /> C - DOUBLE PORCH NO POPOUT AT REAR - <br /> ;; t. <br /> D - DOUBLE PORCH/ POPOUT AT REAR <br /> ' � 1 <br /> --- + \ p� � <br /> E - SMALL DOUBLE PORCH/ NO POPOUT AT REAR \ """- """ � <br /> , _ ....,. ...... <br /> � ' EGRESS ' ' ' <br /> F - SMALL DOUBLE PORCH/ POPOUT AT REAR '1' "' g_ _ • • t � <br /> � <br /> .... .......... .................... � 6-0 5-6 DBL SL <br /> � 0 5 0 DBL SL �........: :....... ....... .. ..........� <br /> , » � C�D 8'-0" A.F.F. � � _ 1 <br /> 1 1 �i 7-4 A.F.F. I j� � �`�`� ` ��� 1' �. <br /> --- � ' i <br /> i D1 \ � i � --- --------------------------------------- --`��� ' , <br />� SEE BUILDING PLANS FOR WNERE � <br /> VARIATIONS OCCUR ( � � �� � , ,�, ;r 1, <br /> � �- � C � UL APPROVED ��;" � ; <br /> 1 � l � j, ;_�, � ELECTRIC FIREPLACE �; � I� � ' <br /> � o j � � � I� FLOOR '� ,� � � <� �` � � � � ;;: <br /> ' ,� I �� , BELOW TILE HEARTN � � � � ',�y � � � � °� � ;; <br /> IN�UL_ATION . i <br />, FOUNDATION PERlMETER - R-10 RIGID UPPER LEVEL PV�,N ' � � �' ^ ' <br /> INSULATION TO A DEPTN OF 24" OR TO TOP 25 �er�tral 6'Vay, �u��,�: 2T0 ; <br /> U � �� E7 g, E1 D 8� E1 F W/REAR POPUUT �;��,�,,,�z���,�,��fi�� �g��3 <br /> OF FOOTING AT HEATED PERIMETER MIDDLE LEVEL PLAN <br /> WALLS: 2x6 WALLS WITH FIBERGLASS BATT5 1�4"=1'-0" U � �� E� � E1 D t�c E1 F W/REAR POPOUT �� ,��� ������� F ������ ���� ` <br /> ' OR BLANKETS - R21 / POP-OUT ABOVE AT UNIT E1B, E1D & E1F �;�E� �vmv�+ r��i��►�a�tdta�'ck� €gr�t > <br /> ; . _ <br /> 1/4"=1'-0" (SEE ELEVATIONS WHERE OCCURS) <br /> ,-.: ;; ._, <br /> FLOORS OVER UNHEATED SPACES - R-30 15'-4" 15'-4" <br /> • ATTICS AT TRUSSES - R-49 15'-4" , 5'-83�4" 9' 7��" <br /> (R-38 SNALL BE DEEMED TO SATISFY TNE � 5_83/4" 6'-103�4�� 2�_�1�2» ' 5�_9�� 9'-7" 5052 <br /> REQUlREMENT OF R-49 WHEREVER THE FULL REGISTERED <br /> 6-0 5-6 DBL SL � I , FLOOR ABOVE � ARCHIT_CT <br /> HEIGNT OF UNCOMPRESSED INSULATION EXTENDS � 6-0 5- DBL SL � , ------- � <br /> � 8'-0 A.F.F. D1 � �---------- � � <br /> OVER TNE WALL TOP PLATE AT TNE EAVES) I � 7'- A.F.F. � T �_� L_________� /fJ <br /> — ............. .......... .......... � � ji�� <br /> ...... <br /> ............... ...... .............. <br /> �•••••e••.•••�• � � � 2x4 FUR � ROBERT E. WEIBLE <br /> .�..... .. � <br /> EXTERIOR DOQRS; DOORS BETWEEN NEATED ( EGRESS 1 � �`�:� �`� �� f �_ WALL Q W.H. STATE OF WASHWGTON <br />� AND UNHEATED SPACES SHALL BE U=0.30 1 1 � � 1' .,�, � i � <br /> OR BETTER � D1 � � 1 � - - --- �� � � � � <br /> --- ------------ -------------------------- <br /> � h I ( 1 ��, ^� I, � 8-0 7 0 SOHD <br /> i ' � UL APPROVED ���`' � � <br /> WINDOWS: ALL WINDOWS AND SGD TO NAVE j � � I a j � ELECTftIC FIREPLACE \�; �� \ 15 11 14 1 WH <br /> , U-FACTOR OF U=0.30 OR BETTER ¢ - _ <br /> (� m j � �� `n 'i FLOOR �� � D5 D2 D5 D1 � � <br /> INSULATE UNDER STAIRS AND IN WALL I� o ! � j co ,� BELOW TlLE HEARTH ( 3'-4" � <br /> CAVIT(ES ABOVE BOTTOM �F STRINGERS - ') i I �� � � � � <br />� • "i' I� Bedroom C° � 1� (� (QPTIONAL) i I � <br /> �, ,1 3'_51 �,_2„ 2� �g1 1, �, . _ , NOTE: PER IRC R302.6 MIN. �, <br /> .- g'_p» �2" � �2' � '; �' � „ <br /> ' o� I Living � q, %a TYPE X GWB SHALL BE ` -� <br /> � � -� ,� �, _� i �g APPLIED T0 CEILING OF GARAGE '� <br /> GYPSUM WALLBOARD SCHEDULE �1 �, �- �- �-- <br /> � 2xs � � I� WSULATE FLOOR OVER � � ( D1 WHERE HABITABLE ROOMS ARE i � <br /> ABOVE. MIN.Y2" GWB APPLIED TO � <br /> 1 � �� g UNHEATED SPACE g �� � 8 ALL bVALLS, BEAMS, AND POSTS 8 �- <br /> %a" GYPSUM WALL.BQARD (GWB) SHALL BE g �, � <br /> USED TNROUGHOUT ON INTERIOR WALLS, .� p� � _______ . ' D1 p� � �� WITHIN GARAGE. D1 � <br /> r---� <br />. INTERIOR SIDE OF EXTERIOR WALLS AND �� 2 i I W/D I �� Q `1 LOW WALL I' ;N � SIM. S(M. i � <br /> CEILWGS EXCEPT AT EXTERIOR WALLS AND � Q1 I� � +42 AFF � \ <br /> , � Gara e � � <br /> COMMON WALLS REQUIRED TO NAVE A 1-HR �� `p I � g <br /> OR 2-NR FIRE-RESISTANCE RATING IN '� `� 1� �� '-4" 2'-6" 7'-8" 2'-6" 1'-4 jj � � ' i � <br /> ' Yz" GWB, (NSULATE � � <br /> , WH)CN CASE %a" TYPE 'X' GWB SNALL BE � ` � 3-0 BIFOLD � `� i' � ' <br /> 1 <br /> USED. ' � �� Bath `r (- � � - ---------------- - ------ -- 1 UNDER STAIRS ' � <br /> "N �' i m� N �22°X3��( �(8 � � N ��� ,' . . .. . . . . . .' .. . . . . . i�i �( i � <br /> � 15 . � ��«��.�.���,,����------- � � � 5�_8�. 3,,2„ 6,_6„ � <br /> � � �o I ATTIC 1; i <br /> � � D3 � ,' ~c=n I ACCESS I �� � `'� � SOFFIT AT 7'-6" AFF �9 � _ � <br /> o � ,� � o � P � o L-_J �N �, �j GONTINUE COMMON WALL D1 1 N � <br /> LOCATE PLUMBING � � a � � �� GWB THROUGH FURRING � � � <br /> � � 18" T8 � � �� �� ?� � � <br /> ROUGH-IN ACCOUNTING � '� ' — �o �- �� � TYPICAL p� � °�° <br /> FOR SHEAR PANELING � � - "- � <br /> AND (2) LAYERS GWB �' � �o � �� AT�+42'LLA.�.F. o 'j LOW WALL ^ �� � STEPS AS L- --- o � <br />• AT COMMON WALL � ° `° z `�' G� � W/ WOOD CAP i ; I) +42" A.F.F. ;� � Q I RE RED � � i __ � <br /> ,i j 5' SHOWER �' � ;' - a' � �I 'Y' 3� 7�, '� D2 D1 I __ 5 � � Z � <br /> `Z` ( I � 1� a, � 9 3 D2 I------ o <br /> �) 3 � � �� �� I L--- D5 <br /> �J �. Bath z '� '- � D�n�ng ' '�•��2•6�PLU BING.WALL. � I i <br /> ^ (1 2-4 HC � , ^ <br /> I � � � .. ..6.,P,UM �— .. <br /> 24° TB I �i I) N o� � � ... .'i � <br /> � � � N j � LOW WAL� � � � I j � `�' � •is•&•P• •"�. � � <br /> 1 <br />' . °p �� ;�, RAISED �LOOR �j , +36" ABV. NOSING 1 i' � T �, 1� �- o <br /> TP � o � I � N <br /> II � I ' ' 2'-8' 1 D3 � �� Pwdr z 2-Q I � � <br /> , a � <br /> ' I � �n � ( I�. �+' BIFOLD � �' n <br /> � i ( � I _ -ti 18" TB � I ' <br /> � � I 1 N 'j � _ �� 1 �� 11 � <br /> � 2 - --- --- � �� , Kitchen ; �� � - -`� � �3 <br /> �j 1 �, D1 � 2' �8%, � �) I � 1� 16 '� 2 'RATED2S�MFN� `V li � � <br />, � 8'-3�2 3'-2' ��T2 2 �I I <br /> '' I I t ^ i ^N D3 (I �� CLOSING :�v I � W � � � <br /> v�"i 1 N ( � � 1 \ � ;; <br /> (� PLANT SHELF AT +36 A.F.F. m � � � i i � �P i "r' � LOW WALL +42" 3'P7" � � � � Z � P <br /> W L O W W A L L B E L O W o ;Y, � � � <br /> o ,1 � � � � ' a �' �-- � j \ i ABV. NOSING 8 '� `� � � .s.1 � <br /> � �� r i� � � ,� N �� 8 D e n D 1 <br />, � I) I 1 0 '� I O ( _ o II D1 10'-0�2" � � W � <br /> � � �� Nook � L OW W A L L , Ent�/ � n OC <br /> ''� Master i ;' ; O 3'_6" 2'_3" 3'-2�2" 3'-10�2" � � C� +42" ABV. � ' I �I �' � .. (, <br /> 1 Bedroom I 1, �) � o �, � LANDING ,� 6 ;N � f Q W O m � <br /> (I I 1 II � � (� �� /^ D4 � D1 �i � � � � � > <br /> 1 r I� � � I � �� � � � <br /> :............. � ��...��8.... ....�xs ......� I............. . .1� r <br /> . ; <br /> ............ ..............�� .. .. . <br />� � I ^ o � o j DW j ; 1-2 3-,0 FIXED � - �-0 5 0 SH . 3 5-0 SH... .� W <br /> �' o � � � 8�-0�' A.F.F. � �i OVERHANG � � 6'-8�A.F.F. � �' 8" A.F.F. j Porch � <br /> r � ' ' ' L-.__�1 : <br /> N : �'� EGRESS • N `� f ;.. ..: � �v ABOVE <br /> ; � <br /> . . ... ---- -----�+----� \ <br /> � �, � ' � 7-0 5- DBL SL 6 I ' � 4,_9„ 3'_6'° � I �2 � "'i � o <br /> 7-Q 5- DBL SL � ' <br /> � 6 C� 7'-�' A.F.F. ' 3 4 C� 8'-Oi' A.F.F. D3 ' � I D6 5'-105�8» ��» I � � e- <br /> � � I ,-�'_' � U <br /> � D4 4'-4,� � 4�_4» ��_9�2» 2�_8�2,� � , I \ � � _ <br /> 4,_4" 4'-4" 2'-4" 2'-2" � � � I � <br /> � ' 2'-2" 8'-8" 4'-6" ' 2'-2" 8'-8" 4,_6» � � � r <br /> � 15'-4" � ;-- �,.-- ---------- -J <br /> P <br /> 10'-0�4" 4�_��� � <br />. 15'-4" Q j <br /> N O T E S <br /> F R A M I N G: 2 x 6's A T E X T E R I O R W A L L S TH E F I R E P L A C E S H A L L 8 E L l S T E D B Y U L O R F M A N D �, � <br /> 2x4's AT INTERIOR WALLS SHALL BE INSTALLED IN ACCORDANCE WITN THAT � <br /> UNLESS NOTED OTHERWISE. LISTWG l�1 N �T E 1 A E 1 � �c E� E UPPER LEVEL PI_AN U � I T� E 7/�, �1 � E 1 M I D D L E L E V E L P L A N �1 N 1 T' E 1 A �c E 1 � L OWER LEVEL PLA.N � t� <br /> , �._ , „ „ � ,� �, <br /> S E E 5 1.1 F O R S T U D S C H E Q U L E, 1/4�"=1'-0" 1/4 -1 -0 1/4 =1 -0 ; � <br /> PROVIDE WATER RESISTANT GYPSUM WALLBOARD � <br />` •••••••••••••••••• R-21 BATT INSULATION BEHIND TUB AND SHOWER ENCLOSURE MATERIALS . � o <br /> ------ 3%z" ACOUST. INSUL EACH SIDE TO A HEIGHT OF 70" MINIMUM ABOVE TNE � � 0 V <br /> OF PARTY WALL, UNO. DRAIN WLET. � �, ntC� ' .- �' n��,,,Y � � <br /> CONCEALED SPACES SNALL BE FIRESTOPPED IN BOTH NO PLUMBWG, MECHANICAL EQUIPMENT, DUCTS OR 1 � � � � <br /> DIRECTIONS AT 10'-0" ON CENTER AND AT FLOORS. VENTS SHALL 8E LOCATED W THE COMMON UNIT '� 4 � � i, 'i 4 � � �� � ,� � <br /> TYP�CAL. SEPARATION WAL�S PER IRC SEC. R302.2 (EXCEPTION) I � � 1 I � N� <br /> ,� � � 1 I i � � � � � <br /> 1 i-- "� �� ,� �� ') i- ;� D1 �!� �, � � � � <br /> ALL ESCAPE OR RESCUE WINDOWS FROM SLEEPfNG ALL BEDROOM AND BATHROOM DOORS SHALL BE I..........,.. ... .,....,.. .1� �I.. .......... ... . ........ . .1� � <br /> ROOMS SHALL HAVE A MINIMUM NET CLEAR OPENING UNDERCUT A MINIMUM OF 3/a" ABQVE TNE ADJACENT a-0 5-0 SH 3- 5-0 SH 3-0 5-0 SH 3-0 5-0 SN F- '� � <br /> OF 5.7 SQUARE FEET. TNE MiNIMUM CLEAR OPENWG FLOOR COVERING. I . . , „ I ( I > > „ I z <br /> ^ HEIGHT DIMENS(ON SHALL BE 24". THE MINIMUM CLEAR � � 6-8' A.F.F. c� 6� 8 A.f`.F. � Porch � � � 6-8' A.F.F. C� 6'-8 A.F.F. I o�o � � � � <br /> OPENING WIDTN DIMENSION SHALL BE 20". SILL TNE FRONT DOOR SHALL BE OPENABLE FROM THE � T � I �- � �`� W � � � <br /> NEIGNT SHALL BE NOT MORE THAN 44" ABOVE TNE INSIDE WITHOUT THE USE OF A KEY OR ANY SPECIA� �N �oO �� ' � �`� �, W � <br />' . FLOOR PER IRC SEC. R310.1.1. KNOWLEDGE OR EFFORT. IT MAY BE PROVIDED WITM A � � � D6 �'-3" � pg �� 0 <br /> NIGHT LATCH, DEAQ BO�T OR SECURiTY CNAIN, � `D - �- Double Porch -� ��� '� <br /> WHERE SILL AT OPERABLE WINDOW IS LOCATED MORE PROVIDED SUCH DEVICES ARE OPENABLE FROM THE � ' � � \ � �� � "'�' � <br /> � THAN 72 INCHES ABOVE FINlSHED GRADE OR OTHER INSIDE WITHOUT THE USE OF A KEY OR TOOL, AND 'ao � � � � ' 1 � - �" �1 <br /> SURFACE BELOW, SILL HEIGHT SNALL BE MINIMUM 24 MOUNTED NOT TO EXCEED 48" ABOVE THE FINISHED �°�' ,I -j— `- � � � _ � <br /> INCHES ABOVE FINISHED FLOQR. PER !RC SEG. 312.2.1. FLOOR. � � =�_ ___ ___ � <br /> ���— ---- -- � <br /> ; �-------- --- - Q 0. <br />, ALL GLAZING SNALL CONFORM TO IRC SEC. R308.4, STAIR NOTES: pT T_� � � � <br /> 1 1�8 9 ��8 4'-0,� 9., <br /> AZARQOUS LOCATIONS. GLAZlNG IN ALL DOORS SHALL LOCATE NANDRAILS AT 34'-38" ABOVE THE 8'-13�g" 7'-25/g" <br /> � <br /> BE SAFETY G�AZED. AL� GLAZlNG WITHIN A 24" ARC STAIR NQSING. 15'-6" � <br /> OF ElTH�R VERTICAL DOOR EDGE SHALL BE SAFETY 10'-1" 4'-0" <br /> , GLAZED. ALL GLAZING WITHIN 60" OF A HAZARDOUS HANDRAIL GRASP DIMENSION SHALL E3E BETWEEN 9" & � <br /> L.00ATIQN, OR "WET SURFACE" SHALL BE SAFETY 1-1/4". PROV(DE CONTINUOUS HANDRAIL OR 15'-4" � <br /> ��AZEo. TERM��,ATE SEE U17 ��R l�ITERIOR ELEVATI�NS U � I-C E� E E7 F LOWER LEVEL PL � Job No : 13-47 <br />� AT NEWEL POSTS OR SAFETY TERMINAL. � AN � � �� E� � � D LaWER LEVEL PLAN `'`' <br /> ' PROVIDE 5/s (MIN.) GYPSUM SH�ATHING ON � Sheet No.: <br /> WALLS BEHIND TUB/SNOWERS TO SATlSFY FIRE WHERE USED AS A GUARDRAtL, A MAX. OPENING OF ,qND 1NTER�C�R STAIR PLANS ��4�-�r-Q� 1/4"=1'-0" L <br /> � REQUIREMENTS AT UNIT SEPARATION WALLS CONDITION. 4��• � U � <br /> � <br /> Sheet Order: � �i U F � � S � � � <br /> T <br />