July 26, 1999 <br />Bill Brieve <br />Brieve & Associates <br />1944 Duvall Ave., N.E. <br />Renton WA 98059 <br />Subject: Project: 24 Mr. Fitness <br />Address: 10110 Evergreen Way <br />Plan Check No. B9907-046 <br />Dear Mr. Brieve: <br />In response to your application for a construction permit, your plans have been re- <br />examined and you are advised that the issuance of a permit is being withheld for the <br />reasons listed on the attached. These comments address building issues only. Additional <br />revisions or additions may be required by other departments (such as Utilities, Planning <br />or Fire). All references refer to the 1994 Uniform Building Code, as amended by the <br />State of Washington and/or Washington State Energy Code 1994 Edition, unless stated <br />otherwise. <br />In order for the processing of your application to continue, it will be necessary to <br />provide the Building Division with two complete new sets of drawings reflecting the <br />corrections requested. <br />1. This review is only for phase II of the project. Phase III will require a separate <br />submittal. <br />2. The type of construction, building ar.a, occupancy classifications, occupant load, <br />sprinklers and fire alarm information should be shown on the cover sheet. <br />3. To mitigate the Kid's Care area (short of an E-3 Occupancy classification), the walls <br />surrounding the space should be constructed as for a one -hour occupancy separation <br />and doors should be rated for one -hour fire resistance. Section 302.3. <br />4. Safety glazing should be shown for the glazing within 24" of a door (closed position). <br />The relites into the room `office' should be revised. Section 2406.4. <br />5. Typical wall construction and bracing sections should be provided. <br />CI i Y OF EVERETT• 3200 Cedar Street • Everett. WA 98201 9 (425) 257-8800 • Fax (425) 257-8856 <br />