Laserfiche WebLink
_ , <br /> E3 UNIT VARIATIONS � <br /> A - BASIC PORCN/ NO POPQUT AT REAR <br /> B - BASIC PORCH/ i'OPOUT AT REAR <br /> C - ENHANCED PORCH/ NO POPOUT AT REAR <br /> D - ENHANCED PORCH/ POPOUT AT REAR <br /> SEE BUILDING PLANS FOR WHERE • <br /> VARIATIONS OCGUR 1 <br /> � <br /> , � ;; - <br /> . <br /> � <br /> � � �;:�� � : � �:� a 1'; ; <br /> . . <br /> INSUL,�ATION <br /> � � � � � � �t � � � .: <br /> �i �'; � <br /> FOUNDATION PERIMETER - R-10 RIGID ' <br /> INSULATION TO A DEPTH OF 24" OR TO TOP �� ������� ���r ��#�����' <br /> OF FOOTING AT HEATED PERiMETER �����������`������°� .`'����� - <br /> WALLS: 2x6 WALLS WITH FIBERGLASS BATTS <br /> � ����4��11,��1 � ���6�8 }��S ; <br /> OR BL.ANKETS - R21 <br /> `���n��� ����r��d��r�eh C��s3 ; <br /> FLOORS OVER UNHEATED SPACES - R-30 <br /> ATTICS AT TRUSSES - R-49 . <br /> (R-38 SNALL BE DEEMED TO SATiSFY THE 5052 REGISTERED <br /> REQUlREMENT OF R-49 WHEREVER THE FULL <br /> � ARCHITEGT - <br /> HEIGHT OF UNCOMPRESSED INSULATION EXTENDS � , <br /> OVER THE WALL TOP PLATE AT THE EAVES) -� <br /> . ROBERT E. WEIBLE <br /> EXTERIOR DOORS: DOORS BETWEEN HEATED STATE OF WASHINGTON <br /> AND UNHEATED SPACES SHALL BE U=0.30 <br /> OR BETTER <br /> WINDOWS: ALL WINDOWS AND SGD TO HAVE <br /> U-FACTOR OF U=0.3Q OR BETTER I -a <br /> � , <br /> INSULATE UNDER STAIRS AND IN WALL � <br /> CAVITIES ABOVE BOTTOM OF STRINGERS � <br /> � <br /> � . <br /> � <br /> GYPSUM WALLBOARD SCHEDULE a <br /> � <br /> 5/a" GYPSUM WALLBOARD (GWB) SHALL BE a- <br /> USED THROUGHOUT ON INTERlOR WALLS, z <br /> INTERIOR SIDE OF EXTERIOR WALLS AND <br /> CEILlNGS EXCEPT AT EXTERIOR WALLS AND a <br /> COMMON WALLS REQUIRED TO NAVE A 1-NR »' <br /> OR 2-HR FIRE-RESISTANCE RATING IN � <br /> WHlCH CASE 5/a" TYPE 'X' GWB SHALL BE ,Q <br /> USED. ' <br /> � <br /> � <br /> a <br /> � <br /> � <br /> M � <br /> 0 <br /> N <br /> ri <br /> � � <br /> c � . <br /> � � a . <br /> I o <br /> I z Q <br /> � <br /> M � � . <br /> , W � � <br /> n' N <br /> a� , <br /> c e- • <br /> � � <br /> � � . <br /> M � <br /> � <br /> , <br /> W z " � <br /> o N <br /> � � <br /> n O <br /> � �i <br /> M � <br /> ; Wo m � - <br /> � � 3 � <br /> � � � � .� <br /> 0 <br /> ° M <br /> - W <br /> � � <br /> � � � . <br /> .� � a <br /> ", _ <br /> � � <br /> � � j� ABOVE. MIN.7¢" GWB APPLIED TO <br /> � N N z � �. . . ' � � ii I � ( ALL WALIS, BEAMS, AND POSTS � <br /> • r- Q � � � i 'i I 1kiTHIN GARAGE. I = <br /> ; z .. . � � �l___ i � �6 ;, � Carage � _ <br /> N <br /> I � � <br /> I � <br /> W � � i � I 1' D3 SIM. � 4'-�^ 5'-2Yz" s'-sYi` � �, <br /> Q z � II � � i = <br /> v, ¢ :� _----. . . . . . . . . . . . . .---,-.-_.---- � , o � _-.�: � Q� <br /> ; , . <br /> � , . .... ......... .. .:... ...... <br /> NO T E S p d- . -- ---- ---------------------------- --- , I I �I _'-_�-"-I ---'--1NSULATE SOFFIT AROUND BEAM _ __'r__' � <br /> �\ � �� OFFIT 16�� OFF CElLING� � _ � UNDER AND BATH EXHAUST � � <br /> FRAMlNG: 2x6's AT EXTERIOR WALLS THE FIREPLAC� SHAL� BE LISTED BY UC. OR FM AND rn �� '�., 2' 8" � - �sra�Rs 8 �, <br /> 2x4's AT INTERIOR WALLS SHALL BE INSTALLED IN ACCORDANCE WITH THAT �+- �cn �5 P "' ' a a � � °t i � <br /> UNLESS NOTED OTHERWlSE. LISTING � `" � p� � � CONTlNUE COMMON WALL � �',' �., I I O � <br /> SEE S1.1 FOR STUD SCHEDULE. - Q p5 GWB THROUGH FURRING � o - 1J � 9 3 � <br /> � � TYPICAL I� � ....,. .- ..; uP D2 D2 Dt � <br /> PROVIDE WATER RESISTANT GYPSUM WALLBOARD : . 3. . . . . . S�M, " 5 : _ : <br /> .................. � <br /> , ______ R-21 BATT INSULATION BEH(ND TUB AND SHOWER ENCLOSURE MATERIALS ; _. . . . . . j, � siM. ; � ��� �� ����� � CI,� . <br /> 3�/2 ACOUST. INSUL. EACH S1DE TO A HEiGHT OF 70 MIMMUM ABOVE THE • '� <br /> , . ' : � � <br /> o � �� W o U <br /> , L1 <br /> `"i . . SQFFI T C� � • � �, <br /> • OF PARTY WALL, UNO. DRAIN INL�T. 7'-10" A.F.F. D111./Fam. i �, o, o' "o" ' m�� °' '�"' <br /> N ' o LOW WALL AT � o ��� . _..N� = Bath '� o � D3 � W � � <br /> CONCEALED SPACES SHALL BE F(RESTOPPED IN BOTH NO PLUMBWG MECHANICAL EQUIPMENT DUCTS OR � ���r' x +�a" ABOYE : o , �, �. Si�. � _ N ' <br /> , , �, I ^ ^ NOSING. RAIUNG � "� i z4'�e S <br /> ; 24.TB. . . . � o N � <br /> DIRECTIONS AT 10'-0" ON CENTER AND AT FLOORS. VENTS SHALL BE LOCATED W TNE COMMQN UNIT � 1 r? ABOYE TO+36^ : o <br /> ' INSULATE FLOOR OVER ° Z-�"� � 2 RoucH iN � � � <br /> T Y P I C A L. S E P A R A T I O N W A L L S P E R I R C S E C. R 3 0 2.2 (E X C E P T I O N) UNHEATED SPACE j � O y � <br /> � .'. .'. . . .'7P.�. , . . . . z � UP D5 �� � FOR (2) L <br /> ALL ESCAPE OR RESCUE WINDOWS FROM SLEEPING ALL BEDROOM AND BATHRQOM DOORS SHALL BE ° - � � Ent � AT COMMC � � � � <br /> .......... ...................... ............ <br /> ROOMS SHALL NAVE A MiN�MUM NET CLEAR OPENING 3 " � —�- 2'-s" 2�-0Y� '�-3y' � ,+-+ L <br /> UNDERCUT A MINIMUM OF /q ABOVE TNE ADJACENT 1-6 42-6 F q 7-0 5-0 DBI� SL I o � �� � <br /> OF 5.7 SQUARE FEET. THE MWIMUM CLEAR OPENiNG FLOOR COVERING. > » > � � � U � � O <br /> �° AT 6 -9 ABOV �� z AT 8-0 A.F.F. ; � ' /• � a i <br /> HEIGH7 DIMENSION SNALL BE 24". THE MINIMUM CLEAR • ' � �' <br /> I G F. :..,... ......: N :. ... Bedroom 3 � W � G� Z . <br /> OPENING WfDTH DIMENSION SHALL BE 20". SILL THE FRONT DOOR SHALL BE OPENABLE FROM THE � �, � �� � I � , ' ^ <br /> HEIGHT SHAL.L BE NOT MORE THAN 44" ABOVE THE 1NSIQE WITHOUT THE USE OF A KEY l?R ANY SPECIAL , � r-3y- r-3y2 : � � o � W = <br /> � FLOOR PER (RC SEC. R310.1.1. KNOWLEDGE OR EFFORT. IT MAY BE PROVIDED WlTH A ' " � i j � ♦..� O <br /> NIGHT LATCH, DEAD BOLT OR SECURITY CHAIN, � i Porch � E�� ■� � � <br /> . WHERE SILL AT OPERABLE WINDOW (S LOCATED MORE PROVIDED SUCH DEVICES ARE OPENABt�E FROM THE � � • j � ; I AT-fi-8'a�. _ • <br /> j ....... o .....,.... , <br /> THAN 72 INCHES ABOVE FINISHEQ GRADE OR OTHER INSIDE WITHOUT THE USE OF A KEY OR TOOL AND � ' s • � �� � � <br /> r> ' I I i�5-6�4 2�_8, � � O . <br /> SURFACE BELOW, SILL NEIGHT SHALL SE MINIMUM 24 MOUNTED NOT TO EXCEED 48 ABOVE THE FINISHED � � <br /> f N C N E S A B O V E F I N(S H E D F L O O R. P E R I R C S E C. 3 1 2.2.1. F L O O R. 2'-9" 2'-4" 5'-0" 5'-0" � ;; ?,� - �-- 2 � •' -________J D1 O �+ <br /> ' 5'-1" 2'-0" 1Q�-0" 2'-d' ^ ^ , -- --,- � <br /> �'-�YB" <br /> ALL GLAZING SHALL CONFORM TQ !RC SEC. R308.4, STAIR NOTES: 19,_1» � �2 uP � <br /> HAZARDOUS LOCATIONS. GLAZING IN ALL QOORS SHALL LOCATE HANDRAILS AT 34'-38" ABOVE THE os 5'-s• <br /> BE SAFETY GLAZED. ALL GLAZING WfTHIN A 24" ARC STAIR NOSING. '�-'y ''�"y" � <br /> OF EITHER VERTICAL DOOR EDGE SHALL BE SAFETY U N 1 T E3A & E3 B MIDDLE LEVEL PLAN <br /> GLA�ED. ALL GLAZING WITHIN 6Q" OF A HAZARDOUS NANDRA(L GRASP DIMENSION SHALL BE BETWEEN 1" & <br /> GLAZED N, OR "WET SURFACE" SHALL B� SAFETY TERMINATE ROVIDE CONTINUOUS HANDRAIL OR 1/4"=1'-0" BUI�DINGS 17 & 18 UNtT E3A & E3B LOWER LEVEL PLAN � 1ob No.: 13-47 <br /> AT NEWEL POSTS OR SAFETY TERMfNAL. SEE U�8 FOR (NTERIOR ELEVATIONS i/4'=�'-o• eui�oiNcs v & ts '� <br /> ! PROVIDE 5/a" (MIN.) GYPSUM SHEATHWG QN z Sheet No.: <br /> WALLS 6ENIND TUB/SHOWERS TO SATfSFY FIRE WHERE USED AS A GUARDRAIL, A MAX. OPENING OF AND INTERI�R STAIR PLANS � <br /> � REQUIREMENTS AT UNIT SEPARAT)ON WALLS CONDITION. 4��• ( � U 7 ■ � <br /> Sheet Order: A B U F R E S D I �. <br /> T <br />