Laserfiche WebLink
srAN�r�: .� <br /> X �t'-1�- <br /> � 30 WATERPROOFING INSULATION ���' ��'Cr� �� <br /> PER ARCHT PLAN , ����}E���;.��' <br /> • � �� �� <br /> � �/� /.� /� /,�//�� /� � � ��. . <br /> � • � i�'����`� <br /> � WALL REINF CONTINUOUS SHEET DRAIN <br /> _, Z ; GONCRETE WALL PER PLAN ��'o�. �,�C'� � <br /> � _ _ _ __ __- _ _ _ � � � (PLACED WITH FfLTER FABRIC � �������' • <br /> �__ __ _ _ _--__� � " ED FACING SHORING) � � <br /> PROJEC�: <br /> - - - - ,� <br /> PIPE SLEEVE, 2" LARGER � � � � �� � <br /> THAN PIPE WRAP = ¢ � w � • $�� <br /> BTWN PIPE & SLEEVE �, � '- J � ¢ o WIDTH OF EXCA ATION i� + SLAB ON GRADE FLOOR ESF FACILITIES <br /> � W/ A COMPRESSIBLE � � � o � � � �„ z \ � PER PLAN �� NON-STRUCTURAL CONC AIL <br /> MATERIAL � � ,w � . » » STEM WALL WALL PER PLAN � RET <br /> � � � � /�//, / NATIVE SOIL FOOTING PER PLAN LAP 24 1Y H <br /> "' �= o I I EXCAVATION • DIA (TYP) E�ERET�T <br /> �--- - -- -- --- � W > I� • 5AT16 OC H & V ATCL <br /> _ _ _ _ _ _ _ _ _ _ _ _�� o � -�� � STRUCTURAL FILL X � �� � ) � <br /> � - - - - - - - - - - - - - � <br /> w ``' 2000 PSI CONC • � SLAB ON GRADE 650�- EVERGREEN WAY <br /> � o � � ; = o PER PLAN EVERETT, WA 98203 . <br /> ,�� TYP FfG REINF i � z <br /> 6„ 6� ,� . z a (2) �5 MIN � � � <br /> F7G WIDTH MIN MIN � • � a <br /> SECTION v !� . � �" � ° � � � MATCH FTG REINF �T <br /> �` DRAIN GRATE � B�ZAN �X <br /> \ : a a <br /> � /,� /��i% �/,�//�'//� <br /> z �� a � � » MATCH FTG REINF �� <br /> �� NOTES: � � � � � � �� � �� � � � a � MIN �' • • ASS�CI���S <br /> 1. THIS DEl-AIL SHOWS PERMISSIBLE LOCATIONS OF PIPES, CONDUITS, EfC UNDER BEARING WALLS. - , � � „ � „ „ � <br /> 2. STEP FTG EA SIDE OF PIPE SO SLEEVE & PIPE WILL PENE(RATE STEM WALL. � � /,A//�//� 8 12 8 (2) �5 CONT �R��IITECTSa INC. <br /> 3. CONC BACK FILL NOT REQUIRED BY STRUCTURAL ENGINEER UNDER NONBEARING WALL FTG WHEN • <br /> . MECHANICAL EXCAVATION IS LESS THAN 1'-0" DEEP BY 1'-0" WIDE. UNLESS NOTED OTHERWISE <br /> DRAIN PER CIVIL 2000 - 116TH AVENLIE NE <br /> & GEOTECH SUITE 4 <br /> BELLEVL.IE, WA 98004 � <br /> TYPICAL PIPE THRU FOOTING DETAIL FOUNDATION DRAIN DETAIL TYPICAL STEPPED FOOTING DETAIL TYPICAL NON—STRUCTURAL WALL FTG 42s.63�.�g�, <br /> SCALE: 3/4" = 1'-0" 1 SCALE: 3/4" = 1 '-0" 2 SCALE: 3/4" = 1'-0" 3 SCALE: 3/4" = 1'-0" 4 FAX.637.1878 <br /> ! NOTE: <br /> 1. ARCHIlEC1URAl DRAYYINGS ARE <br /> �2 7HE PRIME CON'1RACT DRAWINGS. <br /> 15'-0" OC (MAX) 15'-0" OC (MAX) qH�, �„/�p$�� ��N(�,, <br /> �IECHANICAL. PLU�iBINC� � <br /> � Ya" x 1Y" PREMOLDED CONT MASTIC 15'-0" OC (MAX) 15'-0" OC (MAX) 2 ��n�,�wD Fl� <br /> JOINT STRIP OR PREMOLDED CONST SHI1Lt, 8E USED IN <br /> JOINT (MAY BE SAW-CUT AT CONJUNC110N WI'tH ARCHIlEC?URAL . <br /> CONTRACTORS OPTION, SAW-CUT AS STOP SLAB REINF AT JOINT ��� � ��- . <br /> SOON AS SLAB HAS CURED ENOUGH SEE PLAN FOR SLAB PROVIDE Y'�� x 2'-0" PIAIN CON'iRACTOR SHALI. VERIFY AND <br /> TO SUPPORT SAW-CUTTING BAR AT 24" OC COAT BAR TO COORDINAlE DMiIENSIONS AIrIONG . <br /> SLAB ON GRADE SEE PLAN FOR'SLAB EQUIPMENT, & WITHIN 24 HOURS <br /> THICKNESS & REINF (TYP) PREVENT BOND W/ CONC ALL DRAMANGS. ANY <br /> asc��waa, c�oNn�acnoNs, <br /> � = PER PLAN THICKNESS & REINF (TYP) OF SIAB POUR). � ���5 �� � <br /> ``"-' SLOPE AS REQD AT RAMP SLOPE PER ARCHT SLAB ON GRADE Z • • • • REPORIED TO 1HE ARCHITECT FOR <br /> � S�E ARCHT FOR � ¢ � PER PLAN � 3 RE$pLUllqr pRIQR Tp pRp(�Ep�NG <br /> LOCATION & DEPTH FIN GRADE � � � o- �- � � � � -� ,. , ,� � WI,M M�ORK OR FAB�CA,��N OF, <br /> SIAB ON GRADE ,,, � ,�• �/ <br /> OF RECESS (6" MAX) • • • � � - : - <br /> PER PLAN /,\ /. �/ /,\�//. \ /\ � �� i\ ' • ,• . / �,;-�, ,-�J— —, — , � _, 2 OT A�fULL � DRAWING UNLESS , <br /> . z . � ��, •._ _� I I— �— � I — , �— I PRINIED ON 24 x 36 SHEET. IF <br /> /� /� /� iii—iii—ii�—iii—l � i—iii- <br /> • � (2) �5 CONT � • '� ��� —I — — i I� — THIS SHEET IS NOT 24" x 36' <br /> � -i i i—i i i—i i i—i i i--i i i—t t i- COMPACTED GRANULAR FILL SAW-CUT BARS WITNOUT THEN IT IS NOT TO SCAIE - <br /> � z �� �� � „ / / / � z I • • (2) �5 CONT �„ $„ �„ COMPACTED GRANULAR FILL � BURRS OR GRIND SMOOTH <br /> � � 6 � � CONTROL JOINT CONSTRUCTION JOINT PERMIT � <br /> ,�-o�� ,�-o�� A B <br /> , <br /> SET <br /> TYPICAL RECESSED SLAB DETAIL TYPICAL SLAB EDGE DETAIL 6 RAMP DETAIL � TYPICAL SLAB ON GRADE CONTROL JOINT DETAIL $ <br /> SCALE: 3/4" = 1 '-0" 5 SCALE. 3/4" = 1'-0" SCALE: 3/4" = 1'-0" SCALE. 3/4" = 1' 0" <br /> r�ev�sioNs: ��,�re • <br /> . � - <br /> GUARDRAIL PER ARCHT I�' l- 2 - <br /> WHERE OCCURS I I � CITY UPDATES 10 13 17 <br /> , I <br /> I I y" STEEL EMBED PL W/ %"� - <br /> I I H.STUDS x 0'-5" AT 18" OC <br /> II <br /> � RETAINING WALL NOTES: I I <br /> � � � � � � � �� /,� /.�//� <br /> 1. RETAINING WALLS SHALL BE BACKFILLED WITH FREE DRAINING MATERIALS <br /> PER GEOTECH GUIDANCE. PROVIDE FOOTING DRAINS PER CIVIL DRAWINGS. (2) #5 CONT (TOP) <br /> 2. WALLS ARE NOT DESIGNED TO RESIST HYDROSTATIC PRESSURE • <br /> � 3. RESTRAINED REI�AINING WALLS ARE DESIGNED AS SPANNING FROM FOOTING EQ EQ <br /> TO FLOOR ABOVE. WALLS SHALL NOT BE BACKFILLED UNTIL ONE WEEK 18" MIN SURFACE SEAL, NATIVE SOIL OR . <br /> AFI�ER POURING THE CONCRETE SLAB AT THE SUPPORTING FLOOR. OTHER LOW PERMEABLE MATERIAL Q <br /> 4. BACKFILL SHALL BE PLACED ONLY AFTER THE CONCRETE IN THE WALL HAS PER GEOTECH � <br /> GAINED 80% OF THE DESIGNED STRENGTH. BACKFILL MUST BE COMPACTED , ,_ v � - - � " <br /> PER THE GEOTECHNICAL GUIDANCE. N �;����; `�� �� _, -�` ��LL = ` � � • �5 AT 16° OC (H) <br /> 5. CLEAR COVER TO REINFQRCEMENT IN THE RETAINING WALLS SHALL BE AS �-�'-�'� , _ � ��' i ` ��- �V'� �- <br /> � FOLLOWS; � � � _� � � � <br /> r 3" AT FACE POURED AGAWST SHORING � �5 AT 12" OC <br /> � <br /> 2" AT F�ORMED EARTH FACE FREE DRAINING STRUCTURAL <br /> 1" AT INSIDE FACE. � � �� _ \ BACKFILL PER GEOTECH FINfSH GRADE PER <br /> 6. 35PCF SOIL PRESSURE HAS BEEN USED FOR CANTILEVER WALLS , � CIVIL/ARCHT � <br /> NOTES: <br /> � q . <br /> � � � CONC FLOOR � � • FREE DRAINING BACKFILL SHpULD � <br /> z Q <.,� � � � %I � � z w /,A /.� /` DRAWN BY F3MV <br /> Z �,l � SEE ARCHT � �� CONSIST OF SAND AND GRAVEL SOIL � o <br /> a- x L A T E R A L L Y B R A C E D � c, <br /> � o,�,,,, �' H A V I N G L E S S T H A N 5 P E R C E N T F I N E S, _ „ <br /> �5 AT 12 OC (T & B) <br /> "' �m m f �� • = W � � • SHEET DRAIN MAY BE FEASIBLE IN LIEU o � ' CHECKED BY lu� <br /> � � � � � OF FREE DRAINING BACKFILL, PER � � � <br /> r ~� I _ J' ��_- • ,¢ _ � GEOTECHNICAL ENGINEERS z <br /> , ��'' � � � RECOMMENDATONS, � PROJECT# 'n� <br /> � �4 AT 12' OC � "' � � z � FLOOR SLAB ; � _ <br /> �3 NOSING BAR (TYP) - • � � (WHERE ; • DRAIN PIPE SNOULD CONSIST OF � _ ____ <br /> � � � APPLICABLE) � � C�' PERFORATED RIGID PVC PIPE � • � • • 4) #5 CONT SET ISSUC DATE: �5/04/Z017 <br /> �4 UNDER EA RISER v' �T g� g� <br /> .--� �, <br /> �� _ � � r SURROUNDED WITH 1" DRAIN ROCK. EQ 8" EQ • <br /> DOWEL HORIZ BARS INTO ��� <br /> � PERFORATED DRAIN PIPE 4 -� �I�Y �� �V����� SHEE-T TITLE <br /> ADJACENT WALLS W/ 6" EMBED � z SLAB ON GRADE TT��'-'r � . <br /> (SURROUND IN DRAIN ROCK) �������� ��� p����.�., "��r� <br /> � ��:�,� �, <br /> � <br /> �2� �5 50H (PSF) 1" DRAIN ROCK r�.-raiy�,...+� v.��,,.,,S� FOUNDATIQN .� <br /> �6„ PER GEOTECH SITE RETAINING WALL � 2 pw �-� TYPICAL DETAILS <br /> FOR SINGLE LEVEL BASEMENT WALL SCALE. 3 4 = 1 -0 �`""`�y �'-�' <br /> i � <br /> � SHEET# <br /> � PSM CONSULTING ENGINEERS, INC. <br /> 2200 SIXTH AVENUE, SUITE 601 � <br /> DRAINAGE DETAIL SEATT�E, WA 98121 S3 1 <br /> EXTERIOR STAIR ON GRADE DETAIL LOADING DIAGRAM FOR RESTRAINED BUILDING RETAINING WALL FORMED RETAINING WALL (/� <br /> SCALE: 3 4" = 1 '-0" 9 SCALE: 1 4" = 1 '-0" 1 � SCALE: 1 4" = 1'-0" � � P: 206.622.4580 F:206.622.0422 <br /> � � � www.psm-engineers.com � <br />