Laserfiche WebLink
I <br /> 1 60 60 <br /> 77 77 <br /> 65 65 <br /> I <br /> 43 43 <br /> 1.25 1.25 <br /> 3 3 <br /> I 0.98 <br /> 88 0.96 <br /> 50 <br /> 100° 100° <br /> 1 9.5 9.5 <br /> 10 10 <br /> 100%acrylic emulsion <br /> @ 5 cycles show no coagulation or <br /> I change in viscosity greater than± 10 KU <br /> ± 10 KU from the initial viscosity <br /> No Cracks <br /> I Pass at 0.25 in mandrel <br /> >_70%paint retention in wheel track <br /> No Cracks <br /> I1 <br /> 2 The footnotes are supplemented with the following: <br /> 3 <br /> 4 4Cross-linking acrylic shall meet the requirements of federal specification TT-P-1952F <br /> I <br /> 5 Section 3.1.1. <br /> 6 <br /> 7 5CoId Flexibility: The paint shall be applied to an aluminum panel at a wet film thickness <br /> I 8 of 15 mils and allowed to dry under ambient conditions (50±10% RH and 72±5 °F) for 24 <br /> 9 hours. A cylindrical mandrel apparatus (in accordance with ASTM D522 method B) shall <br /> 10 be put in a 40°F refrigerator when the paint is drawn down. After 24 hours, the aluminum <br /> 11 panel with dry paint shall be put in the 40°F refrigerator with the mandrel apparatus for 2 <br /> 12 hours. After 2 hours, the panel and test apparatus shall be removed and immediately <br /> 13 tested to according to ASTM D522 to evaluate cold flexibility. Paint must show no <br /> I 14 evidence of cracking, chipping or flaking when bent 180 degrees over a mandrel bar of <br /> 15 specified diameter. <br /> 16 <br /> 17 6NTPEP test deck, or a test deck conforming to ASTM D713, shall be conducted for a <br /> I18 minimum of six months with the following additional requirements: it shall be applied at <br /> 19 15 wet mils to a test deck that is located at 4ON latitude or higher with at least 10,000 <br /> 20 ADT and which was applied during the months of September through November. <br /> I 21 <br /> 22 'Paint is applied to an approximately 4"x12" aluminum panel using a drawdown bar with <br /> 23 a 50 mil gap. The coated panel is allowed to dry under ambient conditions (50±10% RH <br /> I <br /> 24 and 72±5 °F) for 24 hours. Visual evaluation of the dry film shall reveal no cracks. <br /> 25 <br /> 26 9-34.3 Plastic <br /> I 27 In the first sentence of the last paragraph, "Federal Standard 595" is revised to read "SAE <br /> 28 AMS Standard 595". <br /> 29 <br /> I 30 9-34.3(2) Type B — Pre-Formed Fused Thermoplastic <br /> 31 In the last two paragraphs, each reference to "Federal Standard 595" is revised to read "SAE <br /> 32 AMS Standard 595". <br /> 1 33 <br />