GOMMERCfAL TENANT IMPROVEMENT CHECKLIST <br /> PERMIT SUBMITfAL REQUIREMENTS: <br /> 1. Specia� use reviews (SEPA, etc.) if required, must be compieted prior to permit <br /> submittal <br /> 2. Two complete sets of Uuilding plans that include site plans <br /> 3. One set uf required documentation i.e. engineering caiculations, lighting <br /> budget, etc. <br /> A. Compieted f'erm?t Application <br /> 5. Plan check fee <br /> fi. All docutnents must be clearly legible for microfilming <br /> NOTE—Applications are accepted between the hours of 8:00 AM and 4:00 PM only <br /> The following requirements apply to tenant improvements that do not include additions or <br /> increasing the existing floor area. For addilions, the checklist for new structures must be followed. <br /> A. Include a code data seclion on the coversheet to indicate the occupancy classifications, <br /> lype of construction and occup2nt loads. <br /> D. Indicate on the plans whelher or not the building has an exisling, monitored sprinkier andbr <br /> fire alarm system. <br /> r, 1111 tenant improvements Ihal occur within a building of 4,000 syuare feet or larger are <br /> reyuired to be sealed by an architect currenlly licensed by the State of Washington (RCIN <br /> 10.08). <br /> U. Floor plans wilh complete dimensions. Indicate the proposed use of each space. Show all <br /> er.it doors, stain;, corridors, etc. <br /> G New wall seclior,s sho�.ving construction and assembly ratings i(required. <br /> P. New or revised to'tlet room pians to indude interior elevations, wall and floor finishes, <br /> mounting heighls and clearances and accessibility detaiis (if required). <br /> G. Door, window (refte), room finish and hardware schedules. <br /> H. Revised lighting Flan and energy code analysis. <br />� I. Struclural drawings and calculations to include design loads, material speci(ications and <br /> sUur.tural schedules for revised or altered structural system. <br /> APPLICADLE CODES AND R[FERENCES <br /> o Automalic 1=irr, Deteclion & Suppression Systems Ordinance No. 1902-92 <br /> o infernational f3uilding Code(ISC), 2003 Edition &WAC 51-50 <br /> o Accessiblc and Usablc Buiidin�s & Facilifies,ANSI A117.1-2003 <br /> � Intemational Fire Code(IFC), 2003 Edilion&WAC 51-54 <br /> e Intemalional hlechanical Code (IMC),2003 Edition S WAC 51-5L <br /> . Nalional Elecirical Code (N[C), 2005 Edition&WAC 296-4G3-01i! <br /> � Uni(orm Plumbing Code(UPC),2003 Edillon &WAC 51-;6& 57-5,' <br /> • Washington Slate Energy Code (WSEC), 2004 Edilian,WAC 51-' 1 <br /> • Washinc�lon Stale Ventilation & Indoor Air Quality Code(VIAQ), 2003 Editlon,l'JAC 51-i3 <br /> uae���n p'.�,�r, <br /> CIT"Y OF El%ERL7T f3UILUINP DEP�lRTI�1EfJT 3200 CEDAR ST, EVERE7'T, WA Jt3201 425-2S7-8U10 <br /> �1��riv.o e<v�_�f Rro.oi;� <br /> ( ��h��) <br />