. ::r�,_ <br /> �;;.. <br /> ti ENG/NEE/2/NG/ PU6t/C 5E/�'fo/�E:S �tIEPA�i'T/N��ENT <br /> t_...",r:. <br /> Ocrobcr 30, 2007 <br /> �is. Karen 1lalvcrson <br /> 3231 I.ombard Avciwc <br /> r:���r�u,wn �szot <br /> Projecr Changc of lJsc from SPR to Law OFficcs <br /> Job Address: 3231 �venue <br /> Plan Revicw No• 0706-039 � <br /> Dear Ms. Ilalvcrson, <br /> I'hank you for revising the ramp that projects into thc public right of way so tFat street expansion is possible <br /> by the City of�veretl in the future. <br /> In response to thc revision to the permit drawings, thc plans have hccn examincJ and you arc advi:ed thc <br /> revisions to landscaping and thc front entry to thc building cannot ne issued until the follo�aine issucs arc <br /> resolved. Plcasc proaidc dra�vings which sho�v���hcrc cach itcm in this coircction lcttcr is a�dresscd on lhc <br /> plan set. <br /> Buildin�; <br /> I. }landrails should bc shu�rn on thc drawings on both sidcs o1�hc nc�v sinir and ramp, per I[3C Scction <br /> 1009.11 attachcd. 1�he maximum hcigh[ of tltc hundrail is 38 inches, ano the profile of thc rail <br /> should be `graspable', per IBC Sections 100).11.1 and 1009.113. I3andrails should extcnd Ueyond <br /> the slope ol'thc ramp and thc stair run per IBC Sections i009.11.5 and 1010.8 attachcd. Note that <br /> handrails on the ramp requirc an additional lower r;.il for edge protection, per ICC/ANSI A117.1 <br /> Section 405.9 attachcd. <br /> 2. Guards should Uc shown on the drawings, per the July 8, 2007, Ictter from ihe City of Gverctt (COG). <br /> Guards are only requimd �vhere the open-side of a walking surface, stainvay, ramp or landing <br /> exceeds 30 inchcs above the walking surface or grade below or adjacent, per II3C Section 1012.1 <br /> attached. Guards should be shown on tlic drawings to be 42 inches high, with opening limitations <br /> such that a 4 inch sphcre cannot pass dirough any opcning up to a height of 34 inches. I3erivecn 34 <br /> inches and 42 inches, opening sliould be dimensiimed on the drawings such that a sphere of 8 inch <br /> diametcr cannot pass through. <br /> 3. Pcr the July S, 2007, letter from the City of Everett, the nc�v ramp requires the following information <br /> to be shown on thc drawings: <br /> . Total vcrtical risc; <br /> . Details of thc handrail cross section to meet ICC/ANSI 50�.7; <br /> . Floor surface extending 12 inches minimum beyond ilie inside face of a railing extcnsion requircd <br /> by ICGANSI 505.10 and ICGANSI 40�9.1; <br /> . Curb,bamer or exten�ied surface at the crass-section of the ramp per 1CGANSI 4059; <br /> . The area next to the Joor should be sized to mect the turning radius requiremcnts of ICC/ANSI <br /> 3043.1 or 304.3.2,ucr ICGANSI 405.7.5. <br /> -I. "1'he width of the stair,riscrs and treads should be dimensioned per IBC Sections 1009.1 and 10093. <br /> CITY OF EVERET? • 3200 Cedar Slree; • Everett, WA 98201 • (425) 257-8800 • Fax (425) 257-8856 <br /> ti:N1I laicy\\VnrJ\I10706��39 J231 I.umbard Acc Stair liamp and Ilandrails.do: � <br />