Laserfiche WebLink
����� perbix 820 John Street,n201, SeatUe,WA 96109 <br /> phone 206-264-7784fax 206-264-7769 <br /> �k'I� .�.� bykone� <br /> �tC> � ,�.-��C- <br /> m�morandum <br /> Date: 12/10/10 From: Andy Quinn <br /> To: Botesch, Nash and Hail Architects Projece Northstar ApartmenCs <br /> 2727 Oakes Avenue, Suite 100 Project#: <br /> Everett, WA 98201 Copy�o: file <br /> Attn: Andy Hall <br /> Ro: Exterior wail nailfng <br /> As requested I have reviewed the nailing requirements for the exterior walls <br /> at the Northstar Apartments. Based on the scope of work associated with <br /> tI�P current �roject it is rtiy opinion that the exterior walls should be restored <br /> lo their original condition thereby restoring the original capacfty of the lateral <br /> load resisting system. <br /> Based on the original construction documents prepared by William Arild <br /> Johnson and Associates the exterior walis should be sheathed with Yx" APA <br /> rated sheathing with a minimum span rating of 24/0. The sheathing should <br /> be attached to the framing with 12d common nails at six inches on-center at <br /> the panel edges and twelve inches on-center in the field. Blocking should be <br /> provided at all unsupported panel edges. <br /> Please call me if you have any further questions. <br /> End of inemo <br /> I ; / t� *�� <br /> � / /t ' , �, <br /> `' ��/� <br /> ,; � z; <br /> ��;�,���� �'ra-- <br /> � � ;�� <br /> �. r 3=.s�� ,y :;'.=* <br /> <�.; \rrC�,'�G� ). <br /> <-�.:'J,4) � . �� <br /> r �����L �� <br /> 4 • ��s <br /> �L�q'� <br /> lZ'/t�-Iv <br />