1930 MERRILL CREEK PKY 2015 TRIDENT SEAFOODS Plans 2018-01-02 MF Import (3)
>
Address Records
>
MERRILL CREEK PKY
>
1930
>
TRIDENT SEAFOODS
>
Plans
>
1930 MERRILL CREEK PKY 2015 TRIDENT SEAFOODS Plans 2018-01-02 MF Import (3)
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/8/2022 11:14:40 AM
Creation date
11/16/2018 2:34:41 PM
Metadata
Fields
Template:
Address Document
Street Name
MERRILL CREEK PKY
Street Number
1930
Tenant Name
TRIDENT SEAFOODS
Permit
B1505-059
Year
2015
Notes
IMP
Address Document Type
Plans
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
17
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
r 86 5 <br /> I I 1 I 4 3 2 1 1 l <br /> m <br /> m o <br /> HVAC LEGEND ABBREVIATIONS eo <br /> Ixto gi,o <br /> ROOF MOUNTED AIR HANDLER SCHEDULE ^W9 FLEX ., <br /> CONNECTION ACH AIR CHANGES PER HOUR S Z `� <br /> c� <br /> PI PRESSURE INDICATOR <br /> AFF ABOVE FINISH FLOOR N NEW o 0 2 IS <br /> CONDENSER ECONOMIZER W/ AL ALUMIMUM NC NORMALLY CLOSED Z Z z, <br /> FAN EVAPORATOR COIL INET TEMP HEAT INTEGRATED UNIT --0-- AIR FLOW OS SENSOR, AIR TEMPERATURE AS AUTOMATIC SPRINKLER NIC NOT IN CONTRACT o El w o <br /> °F ENTHALPY NO NORMALLY OPEN Z. E., Ic V <br /> AIR VOLUME TSP COIL EAT°F COIL LAT°F COOLING NET OUTPUT 0T0 100% SERVICE WEIGHT BHP BRAKE HORSEPOWER NTS NOT TO SCALE m <br /> UNIT TAG SERVICE AREA HP VFD 90 MCA MOP IEER EER [LK UNIT HEATER 0 THERMOSTAT, WALL MOUNTED BLDG BUILDING GO,,, <br /> CFM IN W.C. DB/WB DB/WB SENSIBLE MBH MBH MODULATION VOLTAGE LBS. <br /> BOD BOTTOM OF DUCT OAL OUTSIDE AIR LOUVER 6 g o <br /> F RTU-1 SQF EXPANSION 3750 1.75 3 YES 81.6/64 55.7/53.3 96.3 168.6 460/3/60 21.9 30 1750 15.2 12.4 BOP BOTTOM OF PIPE OFCI OWNER FIRNISHED CONTRACTOR F f' C� <br /> FIELD MOUNTED HOUSED T PROPELLER FAN V THERMOSTAT, CEILING BOS BOTTOM OF STEEL INSTALLED 8 c L) <br /> RTU-EXH ECONOMIZER 2470 0.5 2 YES NA NA NA NA 460/3/60 5 9 350 NA �', PENDANT MOUNTED BTU BRITISH THERMAL UNIT OH ORDINARY HAZARD <br /> CENTRIFUGAL FAN _( W/HOUSING OH1 ORD. HAZ. GROUP 1 <br /> TI TEMPERATURE INDICATOR CA COMPRESSED AIR OH2 ORD. HAZ. GROUP 2 c <br /> •pal <br /> PROPELLER FAN CFM CUBIC FEET PER MINUTE OSA OUTSIDE AIR ilg_NOTES: MFG TO PROVIDE: WO/HOUSING CLG CEILING <br /> CLEANOUT OS&Y OUTSIDE STEM 8c YOKE g s <br /> O TEMPERATURE TRANSMITTER CO a o <br /> 1 STRUCTURALLY CALCULATED ROOF CURB COMPETENT WITH IBC 2012;CAN FAB PART#6041-CB14A-CBC WITH CONTROLS PIV POST INDICATING VALVE 3 (13110) <br /> 2 THREE STAGE COOLING AND TWO STAGE HEATING W/SS HEAT EXCHANGER BACK DAMPER 0 DIFFERENTIAL PRESSURE DB DRY BULB POC POINT OF CONNECTION z Z <br /> 3 FACTORY MOUNTED SUPPLY AIR SMOKE DETECTOR WIRED TO AUTOMATICALLY SHUT DOWN THE UNIT ON DETECTION OF SMOKE. N <br /> SENSOR/TRANMITTER DIA DIAMETER PSI POUNDS PER SQUARE INCH W <br /> 4 CONDENSER COIL MARINE COATING,LUVATA ELECTROFIN E-COAT;AND HAIL GUARD DAMPERDN DOWN PSIA PSI - ABSOLUTE ti o <br /> 5 NON FUSED DISCONNECTDP DRY PENDANT PSIG PSI - GAUGE �_ <br /> 6 2 INCH ERV 13 FILTERS / OPPOSED BLADE ii.,) RETURN\EXHAUST AIR DRY DRY PIPE PVC POLYVINYL CHLORIDE <br /> RISER/DUCT(SECTION) <br /> 7 STANDALONE CONTROLS: SINGLE ZONE VAV WITH MICROPROSSOR CONTROLS • E EXISTING RA RETURN AIR <br /> 8 STAINLESS STEEL DRAIN PAN \ DAMPER • <br /> \ 0 RETURN\EXHAUST AIR EAT ENTERING AIR TEMPERATURE RD ROOF DRAIN <br /> PARALLEL BLADE <br /> : 4 <br /> 9 MANUFACTURER WARRANTY:1 YEAR WHOLE UNIT,PARTS+EXTENDED 2ND THROUGH 5TH YEAR COMPRESSOR PARTS+2ND THROUGH 10TH YEAR GAS HEAT EXCHANGER PARTS . . DROP/DUCT EH EXTRA HAZARD REF ROOF EXHAUST FAN <br /> 10 VLTAGE/PHASE MONITOR PROTECTION;FROST PROTECTION SENSOR/LOGIC;CONDENSER FAN HEAD PRESSURE CONTROL EL ELEVATION RM ROOM <br /> \ RETURN\EXHAUST AIR ELO EXTRA LARGE ORIFICE RPM REVOLUTIONS PER MINUTE <br /> 11 COMMERCIAL SALES DIRECT ONLY LOUVER GRILLE ESFR EARLY SUPPRESSION FAST RESPONSE <br /> EWT ENTERING WATER TEMPERATURE SA SUPPLY AIR <br /> , H 0 SUPPLY AIR RISER/DUCT EXH EXHAUST AIR SCFM STANDARD AIR - CFM <br /> (SECTION) SD STORM DRAIN <br /> TRANSFER GRILLE <br /> ,--7, F FUTURE SEF SIDEWALL EXHAUST FAN <br /> _ �X\ 0 SUPPLY AIR DROP/DUCT FC FAIL CLOSED SIM SIMILAR <br /> INLINE FAN FCU FAN COIL UNIT SMACNA SHEET METAL AND AIR CONDITIONING <br /> E �!' / SUPPLY AIR DIFFUSER FD FLOOR DRAIN CONTRACTORS NATIONAL ASSOCIATION4 it 0 i laz:- n; <br /> FDC FIRE DEPARTMENT CONNECTION SPEC(S) SPECIFICATION(S) E <br /> EXHAUST FAN SCHEDULE FL FIRE LINE SPK SPRINKLER <br /> EXTERNAL EFFICIENCY AT 1 ) UPBLAST EXHAUSTER =g, SQUARE TO ROUND FIN CLG FINISH CEILING SS STAINLESS STEELqr <br /> CAPACITY MOTOR ROOF OPENING VFD OR COOK ACCESSORIES FIN FLR FINISH FLOOR SUSP SUSPENDED <br /> TAG NAME SERVICE CFM STATIC LISTED WATTS V/P/HZ FAN RPM SONES WEIGHT INCHES FSC MODEL NOTES STYLE TRANSITION FOB FLAT ON BOTTOM <br /> IN.W.C. CONDITIONS f n` rED FO FAIL OPEN SW SANITARY WASTE <br /> LOCKERS ANDltz <br /> EXHAUSTER I FIRE DAMPER TOR TOP OF RISER <br /> .5 FSC 150R16DEC 1,2 UPBLAST <br /> EF-L1 1600 0.75 102% 306 115/1/60 1146 11.7 121 19.5X 19 I rl FOT FLAT ON TOP <br /> FPM FEET PER MINUTE TOS TOP OF STEEL <br /> 1411111W 3. <br /> REST ROOMS VD VOLUME DAMPER FRE FREEZER <br /> TS TAMPER SWITCH <br /> O CENTRIFUGAL FAN FRP FIBERGLASS REINFORCED PLASTIC TYP TYPICAL <br /> FT FEET w <br /> NOTES: 1.PROVIDE MANUFACTURER'S CURB,CURB MOUNTED INSECT SCREEN,&MOTOR MOUNTED SPEED CONTROLLER �, > REDUCTION DUCT UBC UNIFORM BUILDING CODE <br /> 2.PROVIDE MANUFACTURER'S HORSEPOWER RATED DISCONNECT,PRE WIRED FROM FACTORY SIDEWALL EXHAUSTER GALV GALVANIZED STEEL UH UNIT HEATER <br /> DIFFUSER GPM GALLONS PER MINUTE <br /> "�" PD-1 /DIFFUSER GRILLE TAG NO. <br /> Ea_ 2000 CFM HD HUB DRAIN VR VR VENT RISER <br /> VOLUME DAMPER <br /> `'� <br /> MOTORIZED DAMPER HP HORSEPOWER VTR VENT THROUGH ROOF <br /> 1 7 SLOPE INDICATOR <br /> LAT LEAVING AIR TEMPERATURE W/ WITH <br /> LD LARGE DROP <br /> Q HUMIDITY SENSOR/TRANSMITTER LH LIGHT HAZZARD WC OO WAL BULB <br /> DIFFUSER AND GRILLE SCHEDULE LWT LEAVING WATER TEMPERATURE WDWASH CLEANOUTO <br /> CFM DP INCHES <br /> TAG MOUNTING SURFACE SERVICE MAXIMIMUM MODUILE SIZE IN. NECK SIZE IN. DISCHARGE MAX NC RATING TITUS MODEL M2 SQUARE METER L ANGLE <br /> MAX MAXIMUM DEGREES <br /> SD-1 SUSPENDED CEILING SUPPLY 475 24X 24 12 DIA 4 WAY 0.038 16 TMS MIN MINIMUM DIAMETER <br /> RG-1 SUSPENDED CEILING RETURN 750 24X 24 18X 18 NA 0.050 17 PAR MUA MAKEUP AIR 0 CENTER LINE <br /> TG-1 GYP TRANSFER 400 24 X 24 14 DIA NA 0.050 14 PARc. <br /> D EG-1 GYP EXHAUST 400 24X 24 12 DIA NA 0.100 17 PAR D <br /> EG-2 GYP EXHAUST 800 24 X 24 18 X 18 NA 0.040 15 PAR <br /> EG-3 GYP EXHAUST 50 12 X 12 6 DIA NA 0.020 5 PAR <br /> NOTE:SMACNA TRANSITION FROM NECK SIZE TO CONNECTING DUCT AS REQUIRED <br /> z <br /> 0 <br /> 0 CO <br /> zz <br /> Q a <br /> CL <br /> LLI <br /> C J w <br /> D LL <br /> FAN COD 1_1J CD <br /> CO <br /> POWERED U 0 <br /> ECONOMIZER (`) Q O I <br /> � � Z <br /> oQaa <br /> J <br /> CRTU-1� LZ a <br /> ^ 1600 CFM Li > E <br /> -ril ill- <br /> tE o LI_ o.,'" CC <br /> W Q LJ EEW <br /> A ®A <br /> = Q W <br /> A <br /> c.' <br /> 100,1m <br /> CFM V 100 <br /> -I VD VD p VD ® --7 VD CFM <br /> B _ _ _ _o s� <br /> 50 750 700 400 400 400 400 3650 1500 2150 B I o <br /> CFM CFM CFM CFM CFM CFM CFM CFM CFM CFM o <br /> - o z <br /> 50 0 <br /> CFM <br /> 5 <br /> O 0 0 0 a <br /> z <br /> 0 <br /> ,----- <br /> F <br /> a <br /> JANITOR LOCKER ROOM 100 CFM MENS WOMENS TRAINING/BREAK 8 <br /> ROOM FROM RESTROOM RESTROOM ROOM � 2WAREHOUSE 5 CFM/PERSON cc o <br /> 10 ACH 10 ACH 10 ACH 750 CFM MAX a <br /> 70-75'F 70-75'F 70-75'F 70-75'F c <br /> o <br /> S <br /> L,_ <br /> 0 <br /> w <br /> D <br /> V) <br /> N <br /> N <br /> ci <br /> ROOM PRESSURE LEGEND PROJECT: 1272 <br /> c! <br /> 0 NEUTRAL DATE:05-18-15 <br /> a 0 NEGATIVE A ENGINEER:CW <br /> W 0 POSITIVE DRAWN BY:RAG <br /> 0 <br /> CHECKED BY: - <br /> 9 <br /> SCALE:NONE <br /> mW <br /> v= SHEET:1 OF 1 <br /> o <br /> "s <br /> DRAWING NO. <br /> 12 a <br /> Ei`41 <br /> a=' <br /> Q12.O1.O11930 Merril Creek Pkwy <br /> 8 7 6 5 I 4 I 3 I 2 1 <br /> REV 0 <br />