Laserfiche WebLink
Table 20-10:Building Transparency Requirements(ground floor) <br /> STREET TYPE DESIGNATION(see Map 20-2) <br /> PEDES- PEDESTRIAN RES MIXED UNCLASS- <br /> Standard TOD TRIAN CONNECTOR USE IFIED <br /> Percent comprised <br /> of windows and/or See blank walls <br /> 90% 75% 45% 45% (Section <br /> doors with clear <br /> 20.305(D)) <br /> glass <br /> Illustration 20-12:Transparency Requirements <br /> 75%TRANSPARENCY ALONG <br /> BUILDING FACADE <br /> I <br /> • <br /> 20.340 Special Design Standards <br /> The following site and design requirements apply to development that includes one or more of these design <br /> features,or where development in the Urban Mixed (UM)zone abuts a residential zone along a rear property line. <br /> A. Building Entrances <br /> The main entrance to each structure must face the street,courtyard,or plaza.The entire width of main entrances <br /> shall incorporate weather protection as outlined in Table 20-9 and Section 20.320. <br /> B. Recessed Entries <br /> Any entrance that is set back more than three(3)feet from the front building façade shall comply with the <br /> standards set forth in Table 20-11 below. <br /> Table 20-11:Recessed Entries <br /> Standard Illustration Measurement <br /> Travel path width A 4 feet,minimum <br /> Depth of Recessed Entry B 6 feet,maximum <br /> Exhibit 2,Chapter 20,Development Standards 24 8/29/18 <br />