Laserfiche WebLink
PROPOSED LIBERTY HALL,EVERETT COMMUNITY COLLEGE =s; Everett,Washington <br /> Design Parameters <br /> Lateral earth pressures for design of below-grade walls and retaining structures should be <br /> evaluated using an equivalent fluid density of 35 pcf provided that the walls will not be restrained <br /> against rotation when backfill is placed. If the walls will be restrained from rotation,we recommend <br /> using an equivalent fluid density of 55 pcf. Walls are assumed to be restrained if top movement <br /> during backfilling is less than H/1000, where H is the wall height. These lateral soil pressures <br /> assume that the ground surface behind the wall is horizontal. For unrestrained walls with backfill <br /> sloping up at 2H:1V, the design lateral earth pressure should be increased to 55 pcf, while <br /> restrained walls with a 2H:1V sloping backfill should be designed using an equivalent fluid density <br /> of 75 pcf. These lateral soil pressures do not include the effects of surcharges such as floor loads, <br /> traffic loads or other surface loading. Surcharge effects should be included as appropriate. <br /> Below-grade walls for buildings should also include seismic earth pressures. Seismic earth <br /> pressures should be determined using a rectangular distribution of 7H in psf, where H is the wall <br /> height. <br /> If vehicles can approach the tops of exterior walls to within 1/2 the height of the wall, a traffic <br /> surcharge should be added to the wall pressure. For car parking areas, the traffic surcharge can <br /> be approximated by the equivalent weight of an additional 1 foot of soil backfill (125 psf) behind <br /> the wall. For delivery truck parking areas and access driveway areas,the traffic surcharge can be <br /> approximated by the equivalent weight of an additional 2 feet(250 psf) of soil backfill behind the <br /> wall. Other surcharge loads, such as from foundations, construction equipment, or construction <br /> staging areas, should be considered on a case-by-case basis as shown on Figure 5. Positive <br /> drainage should be provided behind below-grade walls and retaining structures as discussed <br /> below. <br /> These recommendations are based on the assumption that all retaining walls will be provided with <br /> adequate drainage. The values for soil bearing, frictional resistance and passive resistance <br /> presented above for foundation design are applicable to retaining wall design. Walls located in <br /> level ground areas should be founded ata depth of 18 inches below the adjacent grade. <br /> • <br /> Wall Drainage <br /> To reduce the potential for hydrostatic water pressure buildup behind the retaining walls, we <br /> recommend that the walls be provided with adequate drainage, as shown in Figure 4. Wall <br /> drainage can be achieved by using free draining wall drainage material with perforated pipes to <br /> discharge the collected water. <br /> Wall drainage material may consist of washed 3/8-inch to No.8 pea gravel per WSDOT 9.03.1(4)C, <br /> AASHTO Grading No.8,or clean gravel (gravel backfill for drains per WSDOT Standard Specification <br /> Section 9-03.12(4)) surrounded with a non-woven geotextile fabric such as Mirafi 14ON (or <br /> approved equivalent). The zone of wall drainage material should be 2 feet wide and should extend <br /> from the base of the wall to within 2 feet of the ground surface. The wall drainage material should <br /> be covered with 2 feet of less permeable material, such as the on-site silty sand that is properly <br /> moisture conditioned and compacted. <br /> Page 18 June 10,2010 GeoEngineers,Inc. <br /> FlIeNo.5836.010.OD <br />