Laserfiche WebLink
Index Hall Replacement: Building Site Flow Control Calculations <br /> 2.444 0.029 0.029 1.443 0.001 <br /> 2.472 0.029 0.030 1.580 0.001 <br /> 2.500 0.029 0.030 1.722 0.001 <br /> Name : Basin 2 Basin 2 contains Conveyance Areas#1 and#3-8. <br /> Bypass: No Basin 2 is tributary to the Detention/Infiltration <br /> GroundWater: No Pipe (as shown on Exhibit A-6),which is modeled as <br /> Gravel Infiltration Bed 2. See below. <br /> Pervious Land Use Acres <br /> C, Lawn, Mod .65 <br /> Impervious Land Use Acres <br /> ROOF TOPS FLAT 0.44 <br /> PARKING MOD 0.62 <br /> Gravel Trench Bed 2 is labeled on the Conveyance Basin <br /> Map as Detention/Infiltration Pipe. See below. <br /> Element Flows To: <br /> Surface Interflow Groundwater <br /> Gravel Trench Bed 2, Gravel Trench Bed 2, <br /> Basin 3 contains Conveyance Area#14. This <br /> Name Basin 3 building roof area is tributary to a surface drainage <br /> Bypass: No feature,and then outlets north without flow <br /> GroundWater: No control. <br /> Pervious Land Use Acres <br /> Impervious Land Use Acres <br /> ROOF TOPS FLAT 0.11 <br /> Element Flows To: <br /> Surface Interflow Groundwater <br /> Basin 4 contains Conveyance Areas#9-12 and 0.29 <br /> Name : Basin 4 acres of bypass area. Basin 3 is tributary to the <br /> Bypass: No <br /> storm system within the Fitness Center and outlets <br /> GroundWater: No without flow control. <br /> Pervious Land Use Acres <br /> C, Lawn, Mod .29 <br /> C, Lawn, Flat .23 <br /> Impervious Land Use Acres. <br /> SIDEWALKS FLAT 0.17 <br /> 4 B-1 <br />