Laserfiche WebLink
Page 1 of 1 <br /> Appended on: 16:01:34 Tuesday,January 25, 2011 <br /> B-012 Event Summary ,2 Eq 1 1 <br /> Event Peak Q (cfs) Peak T (hrs) Hyd Vol (acft) Area (ac) Method Raintype <br /> 6 month 0.0265 7.83 0.0083 0.1100 SBUH TYPE1A <br /> 2 year 0.0388 7.83 0.0122 0.1100 SBUH TYPE1A <br /> 10 year 0.0585 7.83 0.0185 0.1100 SBUH TYPE1A <br /> 25 year 0.0683 7.83 0.0217 0.1100 SBUH TYPE1A <br /> 100 year 0.0864 7.83 0.0277 0.1100 SBUH TYPE1A <br /> Record Id: B-012 <br /> Design Method SBUH Rainfall type TYPE1A <br /> Hyd Intv 10.00 min Peaking Factor 484.00 <br /> Abstraction Coeff 0.20 <br /> Pervious Area (AMC 2) 0.00 ac DCIA 0.11 ac <br /> Pervious CN 0.00 DC CN 98.00 <br /> Pervious TC 0.00 min DC TC 0.94 mm <br /> Directly Connected CN Calc <br /> Description SubArea Sub cn <br /> Impervious surfaces (pavements, roofs, etc) 0.11 ac 98.00 <br /> DC Composited CN (AMC 2) 98.00 <br /> Directly Connected TC Calc <br /> Type Description Length Slope Coeff Misc TT <br /> Sheet Smooth Surfaces.: 0.011 80.00 ft 6.00% 0.0110 1.55 in 0.94 min <br /> Directly Connected TC 0.94min <br /> Licensed to: AHBL <br /> file://C:\Program Files\StormShed2G\110124 IHR\convey.html 1/25/2011 <br />