Laserfiche WebLink
�" PUBL/� I�t/O/�K5 <br /> . <br /> � <br /> ,n>a <br /> I <br /> j��.:. <br /> March 9, 1995 <br /> Ed Peterson, Director <br /> Housing Hope <br /> 3000 W Marine View Drive <br /> Everett W A 98201 <br /> CROSSB APARTMENTS <br /> 3504 Norton Avenue <br /> Dear Mr. Peterson: <br /> This will formalize the City's acceptance of a second exit for the upper two stories of <br /> this building. <br /> The configuration of the stairway may conform to Section 3306(� (spiral stairways) of <br /> the State Building Code and must be located on the north face adjacent to the building <br /> common space. Doors exiting to the stairway must be tight-fitdng smoke and dcaft <br /> control assemblies having a fine protection rating of not less than 20 minutes when <br /> tested in accordance with UBC Standard No. 43-2. Doors shall be maintained self- <br /> closing. <br /> If you have any questions, please feel free to call Frank Marshall at 259-8710 or myself <br /> at259-8810. <br /> Sin rely, <br /> �� �`�_ <br /> TIM TYLER <br /> Building Official <br /> cc: Frank Marshall <br /> Vic Chapman <br /> 7'i:jd:pa:let <br /> CITY OF EVERETT• 3200 Cedar Street• Everett, WA 98201 • (206) 259-8802 • Fax (206) 259-8859 � <br />