REVISION DATE
<br /> �
<br /> GOAL POST �
<br /> " � INFILLED SYNTHETIC TURF I
<br /> ,
<br /> F-2.1 �
<br /> RP �BRASS CAP - ADJUST TO
<br /> UPRIGHT � I TOP OF PAD SYSTEM
<br /> 20' 2" TOP COURSE �
<br /> ,
<br /> PERMEABLE AGGREGATE
<br /> TOP OF CROSSBAR DEPTH MAY VARY OVER . - �
<br /> ELEVATION AT TOP CONCRETE FOOTING � � o oa . � „ I . Q „ o� .
<br /> OF CROSSBAR 8" BASE COURSE � Q � " � � � � � � � " ° , • *
<br /> PERMEABLE AGGREGATE � _ a . �, _ � . � - � E V E R E T T
<br /> � II ° .� � - � � .� D PUBLIC
<br /> " 2" GALV. PIPE; THRE4DED , �� o � �
<br /> � END TO RECIEVE BRASS 1 n � 4 �: ° I . a °� � �;� � � S C N O O L S
<br /> 1TOP OF CAP, SURVEYOR TO MARK '"O�IJ � : `- : : � ' 2
<br /> � � a . a- � � - .4.- - - �
<br /> END LINE TURF INFlLL RP f .005' (X,Y) n/�Q n O e . .. �• ' -
<br /> i � ��.1
<br /> GOAL POST 12"x 12" OR 12"� x18" � �- °�
<br /> FOOTING r CONCRETE FOOTING j I 18"
<br /> SEE DETAIL � II I � . �
<br /> ' PIPE �d � �' �
<br /> '1 I I I ' 36� '� �. � a "':a trl ' � ` �. _-a • :. �
<br /> �) I PROVIDE A 1/2"� � � � �` •' ' � I , je --d �a � �ASCADE
<br /> F-2.4 TO OPPOSITE END OF FlELD -
<br /> FACE OF CROSS BAR TO GALV. THROUGHBOLT � � ,
<br /> TO RESIST ROTATION � I I -I -� ' COMPACTED H I G H S C H D O L
<br /> �
<br /> , FACE OF CROSS BAR _- 12
<br /> SUBGRADE
<br /> COORDINATE FOOTING LOCATION \� - r �
<br /> SYNTHETIC TURF
<br /> WITH GOAL OFFSET DIMENSION
<br /> FIELD
<br /> 1 FO�TBALL GOAL POST 4 RADIUS POINT MONUMENT
<br /> F-�.4 NOT TO SCALE F_2,4, NOT TO SCALE
<br /> � GOAL POST IN CONCREfE FOOTING
<br /> ' SLEEVE OR ANCHOR BOLT ALTERNATE EXPANSION JOINT AND WEAKENED
<br /> PLATE ASSEMBLY PLAN/CONTROL JOINT AT E4CH POST. CONCRETE
<br /> FIELD CENTERLINE PAVING JOINTS TO ALIGN WITH � OF FENCE POSTS I
<br /> � INFlLLED SYNTHETIC TURF SLEEVE OR ANCHOR PLATE r` � WHERE INCLUDED.
<br /> F_2,� COORDINATE TOP OF CONCRETE 0.5" 45' I�
<br /> FOOTING WITH GOAL POST COVER 6" OR 12" 0.5" 45' CHAMFER i .
<br /> AND SYNTHETIC CHAMFER
<br /> TURF INSTALLER 4 „ - � , = . . .
<br /> TOP COURSE F-3.1 - � p • . - - . 2.5 CLR .�. ° ��_.e� ,.� e. D. -• -. , c:
<br /> PERMEABLE AGGREGATE •� � ° �° - Q -'�--- _ -- _
<br /> � p . . • , F '°' - . -' . ��i� Q
<br /> . � .D
<br /> 00 O 00 (3) #4 REBAR � - ' � � ° � " _ � ' ' - '�
<br /> BASE COURSE a �a n ' Q - . • p . � '-e ' , oA D , P. .b• I ' .D� � � �_. � � O ���
<br /> , PERME4BLE AGGREGATE � . _ 12 O.C. (HORIZ.) . . , 4 • -T�.,,_, =��-^ '
<br /> a- .. . IN TOP OF FOOTING O . � ° �-�'-`��'
<br /> _ E e-' � � �' _p • , • �_. g•,- 114 lst Avenue South,Suite 110 p.206.285_0400
<br /> STRUCTURAL SOIL - ' � � - ��- MIN. 2.5" � - • o- � . - �4 REBAR -° �' �� • �p Seattle,Washington 98104 f.206.285.0480
<br /> � �� ��. b . a � �' CONTINUOUS
<br /> BEARING FABRIC - , _•�4 e � , : I � �4„ REBAR � � - _ �_ . � a
<br /> - � - .� °.. 1 Z O.C. (VERT.) -
<br /> CONCRETE GOAL POST �� ."�°A- . _ . �. a • < �� ' p - - � � . .- •p - • � - . � DEPTH QE PLAN VIEW
<br /> FOOTING SUPPORT 6' °�� ' 4=. #4., REBAR C� ' a o' - ' VRRIES 0.5" 45' CHAMFER ► �. �
<br /> 3' SQUARE X 8' DEPTH e�' �- ,• •a � I 12 O.C. (HORIZ.) �p , � � � - a �g^_�2��� E �� j,,. A11T � �
<br /> OR 3' DIA. X 8' DEPTH '.Q � �r : `e_. . - � . R _ _ . O O 1'.1��A� wash���,♦
<br /> � a . � -� � - ' - ..' . � - • . : . .. �
<br /> •�`��• ' d _° . .� MIN. 3" � . 4� . . o• . � � - ° ..�- �a. .. a� - �_ _ • • . a � 4�� � �cz � ►
<br /> ADJUST GOAL POST � - � � _ .� ... , .
<br /> - _ '`. - - 3.. CLEAR (NP) a j . Q =--- " ' �_�_ .�
<br /> CROSSBAR TO 10.0' HT. ��� .. - .Q -- - i � .�o - , - , - - . . . - � �'x ►
<br /> , ABOVE FlNISH FIELD GRADE �, �. ° . . � °-- '<°a.� �
<br /> �'
<br /> . �� '���'�o \�c�w:
<br /> �I�1I I ;" - - �_ '` I�I I� � 4 REBAR 3/8" IMPREGNATED �,
<br /> - p - I I
<br /> _ � , # FlBER BOARD C�D ALL � SSf� E�G �
<br /> II -11 I - � � ' � - � � � � , CONTINUOUS LOCATIONS, FULL DEPTH ► �N�� �
<br /> INSTALL 1/2" DIA. GALV. BOLT TO � I I I I 3. _; � FENCE POST
<br /> PROVIDE CLEARANCE (N GOAL � � D�SECTION LOCATE (2) CONTINUOUS LOCATIONS
<br /> POST SLOT. NOTCH GOAL POST #4 BAR WITHIN THE
<br /> SLEEVE TO ACCOMMODATE BOLT. SUBGRADE BOTTOM 30� OF THE FOELEVATION
<br /> (NOT REQUIRED FOR ANCHOR CURB MASS PROVIDE
<br /> PLATE NPE INSTALLATION) ADE�UATE COVER
<br /> ' 2 FDOTBALL GOAL POST FOOTING 5 C�NCRETE CURB
<br /> F_2,� NOT TO SCALE F_2,4 NOT TO SCALE �INn—c��
<br /> 3/16" STAINLESS
<br /> STEEL AIRCRAFT
<br /> CABLE
<br /> SOCCER GOAL
<br /> ____ __ GROUNDBAR (IYP.)
<br /> -___===_--- SOCCER GOAL �emi- —
<br /> GROUNDBAR ADHERE/ SECURE _— VINYL-CLAD
<br /> _, -- SYNTHEfIC TURF TO GALVANIZED BOX �� PERMIT RESUBMITTAL
<br /> _-- . (IYP.) 3/16 STAINLESS
<br /> TOP OF COVER - _ __- WITH STAINLESS
<br /> ' INFlLLED =------- --= STEEL HARDWARE STEEL AIRCRAFT
<br /> SYNTHETIC INFILLED SYNTHETIC ___--____ - CABLE
<br /> a TURF SYSTEM TURF SYSTEM _ ___ _
<br /> ; �..
<br /> - DATE 6-26-17
<br /> �o _ _ _ ; --- —
<br /> � � LOCKABLE ANCHOR � -- ---= --_ �
<br /> , � — ACCESS HOLE ADHERE SECURE SCALE NTS
<br /> LV
<br /> CABLE WITH SWAGED F-2.1 -- - -.-.. -- LOOP AND CLAMP TO WITH RUBBER SYNTHEZIC TUF2F TO
<br /> � F-2'1 - LOCK LOOP. _- INTERNAL ANCHOR, DROP GROMMET COVER (TYP.)
<br /> � � � LOCK F.I.O.C. <. . THROUGH ALUMINUM DRAWN �CH
<br /> � � � ° � m COVER'S ACCESS HOLE TO ALUMINUM COVER
<br /> 1�8" THICK CHECKED EJG
<br /> N , .a � PROVIDE A SEAMLESS LOOK MATERIAL
<br /> v < < AND STORES CONVENIENTLY
<br /> -- INSIDE BOX W(TH COVER
<br /> o � •
<br /> � � • COPYRIGHT 02017 D.A.HOGAN&ASSOCiATES
<br /> � �► a e `
<br /> O e •
<br /> 3 ° .ea • ' ° .4�
<br /> � � , ` Mu�7l F�E� �.,"4 -,4_•� -. DRILL 3/4" Ho�E ; PLAN APPROVED
<br /> FOUNDATION FOR DRAINAGE PIPE ;
<br /> � BOX & COVER ' ��g�
<br /> f
<br /> � MIN. 2400 PS� z �NST� ,N S�H , -� �`� �— S I T E D ETA I LS
<br /> r CUBIC FOOT PVC PIPE FOR � WELDED SUPPORT (3) � `� � , ---
<br /> a
<br /> �, CONCREfE FOOTING DRAIN HOLE UNQERNEATH FOR ' o�r�c�� eRoston puetl'CWORKs
<br /> ; HEAVY TRAFFlC oEPARTMEM
<br /> � ' w�rEa
<br /> �,
<br /> 'o
<br /> o I SEWER Mnr econmeucrioNP on ras
<br /> NOTE: MIN. 2400 PS) 2 ��o �oR�o n�+nrn+�
<br /> � CUBIC FOOT pR07ECT iS CONDI7ZONAL PER
<br /> � o REMOVE HINGE FUNCTION FROM BOX Tw►F�c CURRLifT �R+TANCA R ,►r�o
<br /> � co►vcR� Foor�Nc S H E ET
<br /> TO PROVIDE REMOVABLE COVER. °f°�"���-'�°NL�
<br /> v�+n foa coNsrnucnon�us
<br /> C CITY ENGINEER BEEN�t1ED.
<br /> G
<br /> " 3 SOCCER GOAL ANCHOR IRI SYNTHETIC TURF
<br /> � �- �
<br /> �
<br /> � F_2_4. NOT TO SCALE
<br /> �
<br /> �
<br /> �
<br /> v
<br /> �
<br />
|