Laserfiche WebLink
, <br /> GENERAL NOTES SPECIAL INSPECTIONS � <br /> � n�E Fowo�nNc �s �Y ac�r wt�� s�owN am�w� <br /> �, <br /> ; � ��`� � °�� *n c� � <br /> �:� ? s��� � a <br /> � �VI�ECiIONS. VEJ�IC�4110N AI� 1E515 OF COMICF�TE CONSTRUC�ION Y�� � ��� � � ���� <br /> � � �. x �.�� � <br /> , � �� <br /> CODE: INTERNATIONAL BUILDING CODE IBC (2015) '�'�� `� � ��� `y � <br /> �� � ��� <br /> � ��� � �� � � ��� �� � 1011 SW Klickitat Way,Suite 208 <br /> INSPECTION OF WELDING: Seattle,WA 98134 <br /> SHOP DRAWINGS SHALL BE SUBMITTED FOR REVIEW PRIOR TO FABRICATION. SHOP DRAWING SUBMIT�ALS PROCESSED BY P: 206.631.8442 � www.oaips.com <br /> , THE ENGINEER ARE NOT CHANGE ORDERS. THE PURPOSE OF SHOP DRAWING SUBMITTALS BY THE CONTRACTOR IS TO a. ADHESIVE ANCHORS INSTA�LED HORIZONTALLY OR UPWARDLY INCLINED X ACI 318: 17.8.2.4 <br /> DEMONSTRATE TO THE ENGINEER THAT THE CONTRACTOR UNDERSTANDS TNE DESIGN CONCEPT, BY INDICATING WHICH ORIENTATIONS TO RESIST SUSTAINED TENSION LOADS <br /> MATERIAL IS INTENDED TO BE FURNISHED AND INSTALLED, AND BY DETAILING THE INTENDED FABRICATION AND <br /> INSTALLATION METHODS. IF DEVIATIONS, DISCREPANCIES, OR CONFLICTS BETWEEN SHOP DRAWING SUBMITTALS AND THE b. MECHANICAL ANCHORS AND ADHESIVE ANCNORS NOT DEFINED IN (a) X ACI 318: 17.82 <br /> CONTRACT QOCUMENTS ARE DISCOVERED EITHER PRIOR TO OR AFTER SHOP DRAWING SUBMITTALS ARE PROCESSED BY <br /> THE ENGINEER, THE DESIGN DRAWINGS AND SPECIFICATIONS SHALL CONTROL AND SHALL BE FOLLOWED. SUBMITI�AL � <br /> REVIEW IS FOR GENERAL CONFORMANCE ONLY; THIS REVIEW DOES NOT CHECK DIMENSIONS OR QUANTITIES. <br /> PSM CONSULTING ENGtNEERS, INC. � <br /> � yp� 2200 SlXTN AVENUE, SUITE 60 1 <br /> � '�,�L �AJ��IAMNJ �"L�\IWIV 1{fJGRL�R�G �J7�N11�1/ IW � SEATTLE, WA 98121 � <br /> ALL CAST-IN-PLACE CONCRETE SHALL BE WITH THE EXPOSURE CATEGORIES, WATER-CEMENT RATIOS, ENTRAINED AIR P:206.622.4580 F:206.622.0422 � <br /> www.psm-engineers.com <br /> AND MINIMUM 28-DAY COMPRESSIVE STRENGTHS AS INDICATED IN THE CONCRETE SCHEDULE ON THIS SHEET. INSPECTION OF WELDING: <br /> ELEMENTS EXPOSURE CATEGORY w/c AIR f'c 1. COMPLEI-E AND PARTIAL PENETRATION GROVE WELDS X <br /> , SLAB ON GRADE FO SO CO 0 2500 <br /> GROUT FOR SETTING BEARING P(ATES 5000 2. MULTI-PASS FILLET WELDS X <br /> 3. SINGLE PASS FILLET WELDS > %6" X AWS D1.1 1704.3.1 <br /> ANCFIORAL�E TO HARDENED CONCf�(E <br /> WHERE EXPANSION ANCHORS ARE SPECIFIED, USE "HILTI KWIK BOLT TZ" (REFERENCE ICC REPORT ESR-1917.) 4. PLUG AND/OR SHOT WELDS X � <br /> WHERE SCREW ANCHORS ARE SPECIFIED, USE °SIMPSON TITEN HD"(REFERENCE ICC REPORT ESR-2713). <br /> WHERE EPDXY ANCHORS ARE SPECIFIED, USE "HILTI HY-200" OR "SIMPSON SET-XP°(REFERENCE ICC REPORT 5. SINGLE PASS FILLEf WELDS < %6" X y� �' �R�'j <br /> ESR-3187 AND ESR-2508�. o � � o <br /> �..��' �,°F �;��f� ��' <br /> 6. FLOOR AND ROOF DECK WELDS <br /> X �,�' � �� � <br /> � � - <br /> "HILTI HIT-RE 500", AND "SIMPSON SET" MAY NOT BE USED, UNLESS SPECIFICALLY PRE-APPROVED BY THE <br /> STRUCTURAL ENGINEER. ' <br /> � ,S, 27135 ti �, <br /> FOR EPDXY ANCHORS, USE ASTM A193 GRADE B7 THREADED ROD, UNLESS OTHERWISE NOTED. HOLES MUST BE �o�,� T�UC`i'�IRA ��`�' <br /> ' CLEANED OF DUST AND DEBRIS AND BE FREE OF STANDING WATER WHEN EPDXY IS INSTALLED. SPECIAL INSPECTION sSI�NAL �� <br /> , OF EPDXY ANCHORS IS REQUIRED. DO NOT CUT ANY REINFORCING BARS TO INSTALL ANCHORS. DEFECTIVE HOLES <br /> SHALL BE FILLED SOLID WITH EPDXY. <br /> FOR ANY SUBSTITUTIONS TO THE ABOVE, THE CONTRACTOR SHALL SUBMIT TO THE STRUCTURAL ENGINEER - <br /> MANUFACTURER'S LITERATURE DESCRIBING THE ANCHORS AND LISTING ICC APPROVED ALLOWABLE SHEAR AND TENSION <br /> VALU ES. <br /> ' �IRI1(!'it IRAI �FF'I� <br /> CHANNELS, ANG�ES, AND PLATES TO BE ASTM A36, FY=36KSI. <br /> ' HSS RECTANGULAR AND SQUARE STRUCTURAL TUBE TO BE ASTM A500, GRADE B, FY=46KS1. <br /> ALL STEEL EXCEPT STEEL EMBEDDED IN CONCRETE SHALL BE GIVEN ONE SHOP COAT OF APPROVED PAINT. W O <br /> � � WELDS TO BE 3/16" MINIMUM CONTINUOUS FILLET, BY CERTIFIED WELDERS USING E70XX ELECTRODES. � � <br /> j ALL WELDING SHALL BE PERFORMED IN STRICT ADHERENCE TO A WRITTEN WELDING PROCEDURE SPECIFICATION (WPS) W Q <br /> � PER AWS D1.1. ALL WELDING PARAMETERS SHALL BE WITHIN THE ELECTRODE MANUFACTURER'S RECOMMENDATIONS. <br /> WELDING PROCEDURES SHALL BE SUBMITTED TO THE OWNER'S TESTING AGENCY FOR REVIEW BEFORE STARTINGJ � <br /> FABRICATION OR ERECTIONS. COPIES OF THE WPS SHALL BE ON SITE AND AVAILABLE TO ALL WELDERS AND THE � '�C <br /> SPECIAL INSPECTOR. C� _ <br /> H <br /> WHERE NOT SPECIFICALLY SHOWN BY DEfAIL, CONNECTIONS SHALL BE BOLTED FRAME BEAM CONNECTIONS PER AISC � O Q � <br /> 0 <br /> i STANDARDS. � m Q � <br /> I DURING ERECTION, STRUCTURAL STEEL SHALL BE SECURED FROM COLLAPSING WITH TEMPORARY BRACING. z z O Q <br /> SUBMIT SHOP DRAWINGS PREPARED BY AN EXPERIENCED DEfAILER FOR REVIEW PRIOR TO FABRICATION. SHOP = Q o0 � <br /> , DRAWINGS TO BE COMPLETE, SHOWING ALL WE�DS AND MATERIAL GRADES. PROVIDE A PLAN LOCATION OR DETAIL ,�S`, CL = � <br /> REFERENCE FOR EACH SHOP DRAWING. FOR MINOR STEEL-TO-STEEL CONNECTIONS OF 12"AND SMALLER STEEL � W � �j <br /> MEMBERS: IF AN EXPLICIT CONNECTION IS NOT SHOWN ON THE STRUCTURAL DRAWINGS, DEfAILER IS TO PROPOSE A � Q � � <br /> CONNECTION SIMILAR TO THE CONNECTIONS ON THE DRAWINGS OR PER AISC STANDARD CONNECTIONS. ON THE SHOP O f1) � � <br /> DRAWING, CLOUD THE CONNECTION AND STATE "VERIFY." SHOP DRAWINGS NOT MEEfING THESE CONDITIONS WILL BE V O o W <br /> REJECTED. REVIEW OF SHOP DRAWINGS BY THE ENGINEER IS FOR DESIGN INTENT ONLY, AND DOES NOT INCLUDE � � c� � <br /> , VERIFICATION OF DIMENSIONS AND QUANTITIES. VERIFICATION OF DIMENSIONS AND QUANTITIES ARE THE RESPONSIBILITY � O <br /> OF THE CONTRACTOR. <br /> W U <br /> STEEL FABRICATORS AND DETAILERS: BASE BID TO INCLUDE STEEL DEfAILER AND FABRICATOR TIME AND COSTS FOR � U <br /> ROUTINE CONSTRUCTION QUESTIONS. ROUTINE CONSTRUCTION QUESTIONS INCLUDE DIMENSIONAL QUESTIONS AND MINOR W � <br /> FRAMING QUESTIONS. ROUTINE CONSTRUCTION QUESTIONS ARE PART OF THE NORMAL CONSTRUCTION PROCESS, AND <br /> ARE TO BE INCLUDED IN THE BASE BID. W � <br /> , <br /> SCOPE OF SfRUCTURAL ENqNFERING SERVICfS: <br /> � THE STRUCTURAL ENGINEER HAS PERFORMED THE STRUCTURAL DESIGN AND PREPARED THE STRUCTURAL WORKING <br /> ' DRAWINGS FOR THIS PROJECT. THE CONSTRUCTION MUST BE PERFORMED IN STRICT ACCORDANCE WITH THE <br /> ' STRUCTURAL DRAWINGS. ANY DEVIATION FROM THE DRAWINGS MUST BE APPROVED IN WRITING BY THE STRUCTURAL <br /> ENGINEER. ERRORS AND/OR OMISSIONS FOUND ON THE STRUCTURAL DRAWINGS MUST BE BROUGHT TO THE � <br /> STRUCTURAL ENGINEER'S ATTENTION IMMEDIATELY. <br /> ARCHITECTURAL DRAWINGS ARE THE PRIME CONTRACT DRAWINGS. STRUCTURAL DRAWINGS SHALL BE USED IN <br /> CONJUNCTION WITH ARCHITECTURAL DRAWINGS. PRIMARY STRUCTURAL ELEMENTS ARE DIMENSIONED ON THE STRUCTURAL ' ' ' <br /> PLANS AND DETAILS. THE GENERAL CONTRACTOR SHALL VERIFY AND COORDINATE DIMENSIONS AMONG ALL DRAWINGS. ' ' <br /> ANY DISCREPANCIES, CONTRADICTIONS, OR OMISSIONS SHALL BE REPORTED T4 THE ARCHITECT FOR RESOLUTION PRIOR ' <br /> TO PROCEEDING WITH WORK OR FABRICATION OF THE ITEM(S) IN QUESTION. j , <br /> THE STRUCTURAL ENGINEER IS RESPONSIBLE FOR THE DESIGN OF THE PRIMARY STRUCTURAL SYSTEM, EXCEPT FOR �,, � �! , <br /> � ANY COMPONENTS NOTED ABOVE. RESPONSIBILITY FOR ANY SECONDARY STRUCTURAL AND NON-STRUCTURAL SYSTEMS � � ' <br /> _ ___ ..__ . <br /> NOT SHOWN ON THE STRUCTURAL PLANS RESTS WITH SOMEONE OTHER THAN THE STRUCTURAL ENGINEER. <br /> THE STRUCTURE SHOWN ON THESE DRAWINGS IS STRUCT�RALLY SOUND ONLY IN ITS COMPLETED FORM. THE ', <br /> CONTRACTOR SHALL PROVIDE ALL NECESSARY BRACING TO STABILIZE THE BUILDING DURING CONSTRUCTION. ' ' ' <br /> THE STRUCTURAL ENGINEER IS NOT RESPONSIBLE FOR, AND WILL NOT HAVE CONTROL OF, CONSTRUCTION MEANS, � I : <br /> METHODS, TECHNIQUES, SEQUENCES OR PROCEDURES, OR FOR SAFETY PRECAUTIONS AND PROGRAMS IN CONNECTION <br /> WITH THE CONSTRUCTION WORK, NOR WILL HE BE RESPONSIBLE FOR THE CONTRACTOR'S FAILURE TO CARRY OUT THE ' ' <br /> CONSTRUCTION WORK IN ACCORDANCE WITH THE CONTRACT DOCUMENTS. vj , , <br /> C , , <br /> , <br /> FIELD MEASUREMENTS AND THE VERIFICATION OF FIELD DIMENSIONS ARE NOT PART OF THE STRUCTURAL ENGINEER'S � ' <br /> RESPONSIBILITY. THE CONTRACTOR MUST CHECK ALL (ASSUMED) EXISTING CONDITIONS SHOWN ON THESE DRAWINGS -� a <br /> � FOR ACCURACY AND NOTIFY THE STRUCTURAL ENGINEER OF ANY DISCREPANCIES. � Q W <br /> �L <br /> OMISSIONS FROM THE DRAWINGS OR SPECIFICATIONS OR THE INADVERTENT MISLABELING OF DETAILS OF WORK WHICH � � p � O <br /> ARE MANIFESTLY NECESSARY TO CARRY OUT THE INTENT OF THE DRAWINGS AND SPECIFICATIONS, OR WHICH ARE 0 � m � � <br /> CUSTOMARILY PERFORMED, SHALL NOT RELIEVE THE CONTRACTOR FROM PERFORMING SUCH OMI�iTED OR INADVERTENT � r-� � m <br /> M I S L A B E L E D D E T A I L S O F T H E W O R K B U T T H E Y S H A L L B E P E R F O R M E D A S I F F U L L Y A N D C O R R E C T L Y S E T F O R T H A N D '� � rn; , m � <br /> DESCRIBED IN THE DRAWINGS AND SPECIFICATIONS. <br /> � � o � c�..� <br /> -a r- � � <br /> � . . +__ . �_.._ __._ � � <br /> � � � r o U <br /> , <br /> Sheet No / Title:i <br /> S1 .0 , <br /> GENERAL <br /> ' N OTES AN D � <br /> SPECIAL <br /> INSPECTIONS <br /> , <br /> Project#: 1000981 <br /> � 0 copyright 2017 <br />