Laserfiche WebLink
• <br /> � � <br /> �_ ' <br /> � PIPING SYMBOLS DUCTWORK SYMBOLS ABBREVIATIONS GENERAL SYMBOLS 1011 SW KlickitatWay, Su�te 20$ <br /> Seattle,WA 98134 <br /> ���— BALL VALVE � DUCT SECTlON - SUPPLY ADA AMERICANS WITH DISABILITIES ACT p_� PLUMBING FIXTURE P: 206.631.8442 � www.oaips.com � <br /> AFF ABOVE FINISHED FLOOR IDENTIFICATION <br /> —,�,�— BALANCING VALVE ARCH. ARCHITECT/ARCHITECTURAL <br /> ' � � BUTTERFLY VALVE DUCT SECTION - RETURN <br /> /r CD CEILING DIFFUSER M-1 EQUIPMENT <br /> � �� CHECK VALVE CG CEILING GRILLE IDENTIFICATION <br /> 20x12 RECTANGULAR DUCT (INSIDE DIMENSION) BOGARD ENGINEERS PS <br /> ��'.�— PRESSURE REDUCING VALVE 'I CO CLEANOUT KITCHEN FIXTURE Meohanical Engineering consultants <br /> 20 �D ROUND DUCT COP COEFFICIENT OF PERFORMANCE K"� IDENTIFICATION 22121 17th Avenue SE,Suite 111 <br /> � �' PRESSURE RELIEF VALVE CONT. CONTINUATION Botheil,Washington 98021 <br /> �WC7 DRAWING Phone:425-415-6100 <br /> . --�I� UNION � FLEX CONNECTION (E� EXISTING ITEMS e-maliaib 9afd@boge�g.net <br /> �, A COMPRESSED AIR J J EA EXHAUST AIR AIR TERMINAL MARK . <br /> F FIRE SPRINKLER PIPE � TURNING VANE EAT ENTERING AIR TEMP. TYPE (SEE <br /> G NATURAL GAS � CEILING DIFFUSER EER ENERGY EFFICIENCY RATING X SCHEDULE) <br /> EFF EFFICIENCY/ EFFICIENT 200 <br /> —�� PIPE DOWN ELECT. ELECTRICAL �— DESIGN CFM <br /> RETURN /EXHAUST/ <br /> i, --�o PIPE UP Q TRANSFER GRILLE OR REGISTER FCO FLOOR CLEANOUT � g�G <br /> IPLV INTEGRATED PART LOAD VALUE DETAIL REFERENCE � y <br /> I SPRINKLER HEAD - PENDANT � VOLUME DAMPER I.E, INVERT ELEVATION DETAIL NUMBER � y/Nc�� <br /> � , o SPRINKLER HEAD - UPRIGHT LAT LEAVING AIR TEMP. � � 02 <br /> ' —�M MOTORIZED DAMPER ,�' � <br /> . LF LINEAR FOOT M2.3 <br /> DRAWING ON WHICH ` � <br /> �!i ���-� COMBINATION SMOKEIFIRE DAMPER MC MECHANICAL CONTRACTOR DETAIL IS LOCATED �'�,� '�FGfsTER `��` <br /> I MECN. MECHANICAL F G�� � <br /> -� <br /> DUCT SMOKE DAMPER NP NON POTABLE SS��NAL EN <br /> I OSA OUTSIDE AIR SECTION REFERENCE <br /> --O BACKDRAFT DAMPER P.O.C. POINT OF CONNECTION <br /> �'i Q THERMOSTAT RG RETURN /RELIEF GRILLE SECTION ID <br /> SA SUPPLY AIR �_ A <br /> QS SENSOR SGNS SENS�R � M2•3 #I DRAWING ON WHICH <br /> , SUPPLY GRILLE <br /> QC CO2 SENSOR T'STAT THERMOSTAT SECTION IS LOCATED , <br /> � TYP TYPICAL <br /> U.O.N. UNLESS OTHERWISE NOTED Q REVISION <br /> V VENT IDENTIFICATION W � <br /> VTR VENT THROUGH ROOF C•7 � <br /> W WASTE 1�. FLAG NOTE W 0 <br /> WCO WALL CLEANOUT J Q <br /> o = <br /> U o �- <br /> � oQ `- <br /> 0 <br /> mo � <br /> H � Q � . <br /> , Z z � ac <br /> � Q m � . <br /> � °- _ � <br /> � � � � <br /> WASHINGT4N STATE ENERGY CODE 2015 GENERAL N�TES MECHANICAL NOTES DRAWING INDEX p U, � w <br /> � � <br /> C403.1 GENERAL PROTECT ALL DUCT OPENINGS OF FIRE RATED ASSEMBLIES PER I.B.C. 716. 1. THE FOLLOWING NOTES APPLY TO ALL MECHANICAL DRAWINGS. DWG. DESCRIPTION V � � w <br /> MECHANICAL SYSTEMS AND EQUIPMENT SERVING HEATING, ADDITIONAL MECHANICAL NOTES MAY BE INDICATED ON EACH <br /> COOLING, VENTILATING,AND OTHE� NEEDS SHALL COMPLY WITH SECTION C403.2 INSTAL� SEISMIC BRACING FOR ALL DUCTWORK, EQUIPMENT AND PIPING MECHANICAL, PLUMBING AND FIRE PROTECTION DRAWING. M0.1 MECHANICAL LEGEND AND NOTES � � <br /> AND SHALL COMPLY WITH SECTIONS C403.3 AND C403.4 BASED ON THE PER I.B.C. REQUIREMENTS. W U <br /> { EQUIPMENT AND SYSTEMS PROVIDED. 2. REFER TO ARCHITECTURAL AND STRUCTURAL DRAWINGS FOR GENERAL M1.1 MECHANICAL FLOOR PLAN � U ; <br /> INSTALL ALL PIPING ON ROOM SIDE OF BUILDING WSULATION. CONSTRUCTION INCLUDING LOUVERS, CONCRETE EQUIPMENT PADS, M1.2 MECHANICAL ROOF PLAN W � <br /> � C403.2.4.3 SHUTOFF DAMPERS FLASHING DETAILS, ETC. <br /> OUTDOOR AIR SUPPLY, EXHAUST OPENINGS AND RELIEF OUTLETS AND MECHANICAL DRAWINGS ARE DIAGRAMMATIC IN NATURE AND DO NOT M2.1 MECHANICAL SECTIONS, DETAILS, AND DIAGRAMS W Q . <br /> S T A I R W A Y A N D S N A F T V E N T S S H A L L B E P R O V I D E D W I T H C L A S S I M O T O R I Z E D N E C E S S A R I L Y R E F L E C T E V E R Y R E Q U I R E D O F F-S E T, F I T T I N G O R A C C E S S O R Y. 3. R E F E R T O P I P I N G D I A G R A M S A N D D E T A I L S F O R R E Q U I R E D F I T T I N G S, V A L V E S, M3.1 FIRE PROTECTION PLAN AND DETAII.S <br /> DAMPERS. RETURN AIR OPENINGS USED FOR AIRSIDE ECONOMIZER OPERATION ETC. FLOOR PLANS AND SECTIONS INDICATE EQUIPMENT LOCATIONS AND . <br /> SHALL BE EQUIPPED WITH CLASS I MOTORIZED DAMPERS. CLASS I DAMPERS THE MECHANICAL CONTRACTOR SHALL VISIT THE JOB SITE PRIOR TO GENERAL PIPE ROUTING ONLY. PROVIDE PIPING SHOP DRAWINGS <br /> SHALL HAVE A MAXIMUM LEAKAGE l�ATE OF 4 CFMIFTZ AT 1.0 INCH WATER GAUGE BEGINNING WORK IN QRDER TO OBSERVE EXISTING CONDITIONS. VERIFY COORDINATED WITH OTHER TRADES. REFER TO SPEC. FOR ADDITIONAL SHOP <br /> WHEN TESTED IN ACCORDANCE WITH AMCA 500D AND SHALL BE LABE�ED BY AN EXACT SIZE, LOCATION AND CONDITION OF ALL EXISTING SYSTEMS, DUCTS, DRAWING REQUIREMENTS. <br /> APPROVED AGENCY FOR SUCH PURPOSE. PIPES, UTILITIES AND BUILDING STRUCTURE. <br /> 4. DUCTWORK STATIC PRESSURE AND SEAL CLASS, BASED UPON SMACNA: <br /> C403.2.4.8 COMBUSTION HEATING EQUIPMENT CONTROLS VERIFY VOLTAGES AT THE SITE PRIOR TO ORDERING ANY EQUIPMENT. <br /> � COMBUSTION HEATING EQUIPMENT WITH A CAPACITY OVER 225,000 BTU/H SHAI.L DUCT SYSTEM STATIC PRESS. SEAL CLASS <br /> HAVE MODULATING OR STAGED COMBUSTION CONTROL. PROVIDE AND INSTALL A COMPLETE AND OPERATIONAL AUTOMATIC FIRE <br /> � SPRINKLER SYSTEM PER N.F.P.A. 13. PROVIDE ALL REQUIRED PIPING, HEADS, A. DOWNSTREAM OF FUME EXHAUST FANS + 6.0" A <br /> C403.2.9.10 MECHANICAL SYSTEMS COMMISSIONING AND COMPLETION VALVES, CONTROLS AND ACCESSORIES. PROVIDE ALL REQUIRED B. UPSTREAM OF FUME EXHAUST FANS -6.0" A � <br /> REQUIREMENTS CALCULATIONS. OBTAIN ANY REQUIRED PERMITS, AND PAY ALL REQUIRED <br /> MECHANICAL SYSTEMS SHALL BE COMMISSIONED AND COMPLETED IN FEES IN ORDER TO INSTALL A COMPLETE AND OPERATIONAL SYSTEM. 5. PROVIDE AIR DISTRIBUTION (SUPPLY/ RETURNIEXHAUST)SHOP DRAWINGS �, <br /> ACCORDANCE WITH SECTION C408. COORDINATED WITH OTHER TRADES. REFER TO SPEC. FOR ADDITIONAL SHOP � <br /> DRAWING REQUIREMENTS. <br /> , <br /> . � <br /> � . <br /> 0 <br /> cn � <br /> '> o <br /> � Q w <br /> � '� � � <br /> O � m � J <br /> '� —� � <br /> cn � >, � <br /> '� � � m � <br /> _,_, o � � <br /> , .� � � � U <br /> � <br /> � �k � p U <br /> Sheet No / Title: � <br /> Mo . � - <br /> �� MECHANICAL <br /> LEGEND <br /> ' AND NOTES � <br /> �, Project #: 1000981 , <br /> , <br /> 0 copyright 2017 <br />