Laserfiche WebLink
� <br /> z <br /> 42'-0" O <br /> � <br /> 12'-4" 20'-0"' 9'-8" w <br /> � <br /> z <br /> O <br /> � <br /> a <br /> � <br /> U <br /> � <br /> W <br /> 0 <br /> W <br /> Q <br /> 42'-0" � <br /> � <br /> > <br /> �'�� c��, o COVERED � <br /> r' PATIO <br /> j��� l�,� <br /> - ' ��/y'� �� ���. <br /> � 2 <br /> O E 1 11 � 10 <br /> �-------- OO ---------�–=-- 4026 ----- 12 <br /> __ ____ oo _______ o <br /> � ` �---------- -- 4036 -------) � <br /> 5040 6040 � � 6040 60 SLIDER I w <br /> � o o � � <br /> � � � SG o o � I � z <br /> � . o � � FP � �� <br /> � � I I � �� <br /> � i I I <br /> I <br /> � 13'-1�� 8'-11��� ��� � I <br /> �,g <br /> � � � <br /> I ,Jv{ Z F "�' CV � � 0 I N i- "' \ � � Z N <br /> , ����� � , "� o o i � o � � i — � <br /> � d � M. BEDROOM o O9 ( N cn � � I -� � Q <br /> {',� � � GREATROOM t- � O � Q Z � � <br /> I tC) O � I I M ? W � J <br /> � <br /> � � � � � O� �.- � � Z �' N � <br /> � � � � I � �' cnQ � C� c� o >- <br /> I - - <br /> � BEDROOM 4 0°o Q°0 18'-5�2' I � i � i ���w � j � <br /> � i N - w F- z � � � <br /> � � I N i <br /> � � I I 8-28-17 <br /> � � � i � I <br /> � N o i I I S McC`�� <br /> � � � I � �1� wAs�,�,d�' <br /> I , <br /> i WI C ���I�'J. ��•�l� G��- i 5-0" i �i�� �/� PANTRY i � � P ' � � <br /> � 1���2a��'ci � I �� � � f � <br /> i � � � r� y�� � � �a 38799 9 w <br /> 3�-0�� � � ��� �' <br /> � <br /> � �ooR � ��� �,�J � I /�`�IONaj..E�� <br /> I WIC � o � o ,� 4'-0" ( � �. � I <br /> !� SD � I� �" <br /> I N � N p �� � ��L�� 36�� � � pp N 0 CMD �%� U � <br />. � � C1 � L�'� LANDING � FAN o � 9 � <br /> 0 <br /> � ,, �s�,• z � �0 41 G► �� o �____�3_a� I ss i o � <br /> ��� � v � DOOR --------- -------- – r' <br /> 0 0 �r� � a �J � --------- <br /> , '� o i � <br /> I o o Sd 1 � � j�� VF l�.(/� �� J � i� � � I � FURN = o 0 <br /> � CMD - <br /> � `�(' DOWN � � � <br /> i o � �. <br /> � 11'-8" � - 12'-0�'� � � HANQRAIL ( I � ( <br /> /� � I � EFFICIENT WATER , � � <br /> � �t �vGJ ' FOaON p ���1�' l /► ; �� � i BOLLARD HEATER PER 5B O ;^? \ l I <br /> I �i�Q�"j 3�_6�� � ,��S HALF WALL � � FOR GAS APPLIANCES TABLE R4062 � � � � <br /> � �WNACJLE � �(l/� SD (MIN. 36") ( ( ELEVATE IGNITION SOURCE (2)SEISMIC 20 MIN. I <br /> � _ �HOUSE FAN. W � � � I 18"A.F.F. IN GARAGE AND STRAPS. i SOLID CORElSTEEL /. ��� I <br />, I � o `���FM. 17'-1" I � PRESS. RELIEF (i ��' � <br /> N _ �� ' O ERATED � PROVIDE IMPACT W/SELF CLOSER � J�� � <br /> � o �le � I PROTECTION. TO EXT. /�- /Ub <br /> I � p -C NTINUOUSLY DRYER VENT � / I - /"' � <br /> ( 8'-4��� � " 0 1.0 S O N E � T H R O U G H R O O F. I ���G � ��V I� G�� � :�,�C 1�-�/ jG,L.�A� ���i�jfiV�,�S �f r��� J Z/1�-.� /'�/S� i <br /> i � N o ,�t�,� ��� ; ��e��-�.:.� 1r%���, �iJ �a� ,��,� w��� <br /> � � �'� � ,C�-,�-`��- I�Di2 c��i�vsz-��'�:�v �-i�� <br /> I 2'_6" BONUS ROOM � _ � I _ � o 0 <br /> I 11'-8" QOOR -N � �7 _ � �. I � �.�,'� � o �5 `� <br /> co in <br /> I � " � � N � � �' `- `' <br /> � o �- � � <br /> � _ BEDROOM 3 � �° � � � 28_8 <br /> � � , �2, <br /> � � s� �¢�f�Y I <br /> � � � � ��� j � I <br /> I I <br /> � ( ( � GARAGE SLOPE <br /> ( � � � 1/2"GWB- WARM WALLS FLOOR � <br /> i \ � i I SUPPORT MEMBERS � <br /> I � � I I 5/8"GWB- CEILING 13 14 � <br /> � 30 O O � <br /> � BEDROOM 2 I �- �� _____ i <br /> � � � –�= QR__ ––––– 5040 <br /> � - <br /> � E 4 11'-7" E 6 I o I � <br /> - <br /> �-- �� O --------/� N I �-- - --- - - ------- - - --- - -- - --- - --P,4-Tle - - - - -- � <br /> ---- 5040 ---- -------- 6040 � v <br /> � 9 FT GARAGE DOOR 16 FT GARAGE DOOR <br /> � � --- N <br /> � � --- � Q <br /> � OO � O � <br />. LINE OF F�OOR�_ (N Q � <br /> —��-- ---- - --- - -- ---- /' <br /> 5040 -_'––––- ABOVE �d% //��� J�/.�� Z N � � <br /> � 1 „ � 1 �� 29'-5�,� 17'-6�2' � � O W <br /> 11 -11�2 � � 17-6�2 10'-0" � O O n/ <br /> 12-6' <br /> 42'-0" z I..L.. <br /> WINDOW SCHEDULE � _ > <br /> LOWER FL�OR PLAN � U W <br /> AREASUMMARY UPPER FLOOR PLAN SCALE: 1/4"= 1'-0° LOCATION SIZE AREA � <br /> 1 6040 24.0 SQ. FT. <br /> UPPER FLOOR 1898 SQ. FT. SCALE: 1/4"= 1'-0" <br /> LOWER FLOOR 1304 SQ. FT. 2 4026 10.0 SQ. FT. <br /> TOTAL HEATED AREA 3202 SQ. FT. EGRESS FANS -50 CFM MIN (UNO),VENT OUTSIDE <br /> 3 5040 20.0 SQ. FT. <br /> GARAGE 677 SQ. FT. 5.7 SQ FT MIN OPENABLE AREA PROVIDE WHOLE HOUSE EXHAUST <br /> 4 5040 20.0 SQ. FT. <br /> 20" MIN. OPENABLE WIDTH <br /> GLAZING SUMMARY 24" MIN. OPENABLE HEIGHT WHOLE HOUSE FAN: LABEL SHALL BE AFFIXED TO THE CONTROL THAT READS"WHOLE HOUSE VENTILATION(SEE 5 5040 20.Q SQ. FT. <br /> 44" MAX ABOVE FIN. FLOOR OPERATING INSTRUCTIONS)"2015 IRC M 1507.3.2 6 6040 24.0 SQ. FT. <br /> TOTAL GLAZING AREA 32�.o sa. F-r. PLAN/LAYOUT <br /> GLAZING: (327/3202 - 10.2%) DRYER VENT 2015 IRC M1502.4.5 LENGTH IDENTIFICATION. WHERE THE EXHAUST DUCT IS CONCEALED WITHIN THE 7- SLIDER 6068 40.0 SQ. FT. w�NDOW <br /> GLAZING BUILDING CONSTRUCTION, THE EQUfVALENT LENGTH OF THE EXHAUST DUCT SHALL BE IDENTIFIED ON A PERMANENT <br /> LABEL OR TAG. THE LABEL OR TAG SHALL BE LOCATED WITHIN 6'OF THE EXHAUST DUCT CONNECTION. 8 4040 �s.o sQ. FT. SCHEDULE <br /> GLAZING AREA(%OF FLOOR) 10.2% 9 6040 24.0 SQ. FT. <br /> WASHINGTON STATE ENERGY CODE REQUIREMENTS U-FACTORS VERTICAL GLAZINGlDOORS 0.30 PROVIDE A 4 SQ IN FRESH AIR INLET TO EACH LIVING AREA. <br /> � } 10 4036 14.0 SQ. FT. <br /> SEC 401.3 POST ENERGY CODE COMPLIANCE CERTIFICATE WITHIN U-FACTORS(OVERHEAD GLAZING) 0.50 <br /> 3 FT OF ELECTRICAL PANEL AVAILABLE AT 11 -SLIDER 6068 40.0 SQ. FT. REVISION: 0 <br /> WWW.ENERGY.WSU.EDU/CODE. INSULATION VALUES DATE: 8-28-17 <br /> SEC 402.4.1 PROVIDE DOOR BLOWER TEST AFFIDAVIT BY FINAL EO EGRESS 12 6040 24.0 SQ. FT. <br /> BUILDING INSPECTION VAULTED CEILINGS: R-38 BATT(500 SQ FT MAX.) DRAWN BY: TJM <br /> VAULTED SCISSOR: R-49 BATT OR BLOWN 5.7 SQ FT MIN OPENABLE AREA 13 1648 7.0 SQ. FT. <br /> SEC 403.1.1 PROVIDE (1} PROGRAMMABLE THERMOSTAT FLAT GEILINGS: R-49 BATT OR BLOWN 20" MIN. OPENABLE WIDTH 14 5040 20.0 SQ. FT. SCALE: AS NOTED <br /> SEC 403.2.2 PROVIDE DUCT SEAUNG AFFIDAVIT BY FINAL EXTERIOR WALLS: R-21 BATT 24" MIN. OPENABLE HEIGHT <br /> INSPECTION 15 6040 24.0 SQ. FT. PROJECT NO: W4371 <br /> SEC 404.1 A MINIMUM OF 75%OF ALL PERMANENTLY INSTALLED FLOOR w/CRAWLSPACE: R-30 BATT 44" MAX ABOVE FIN. FLOOR <br /> LIGHTING SHALL HAVE HIGH EFFICIENCY LIGHTWG SLAB ON GRAQE: R-10 RIGID PERIMETER SHEET NO: <br /> TOTAL 327.0 SQ. FT. S4, <br /> ��i� ���' ������ l� <br />, ������;���� ��� ��������� <br />