<br /> "' ELECTRICAL NOTES: ALL CONSTRUCT�ON TO BE DONE IN CONFORMANCE WITH APPROVED PLANS �
<br /> AND REQUIREMENTS OF THE FOLLOWING CODES (INCLUDWG WA
<br /> - SMOKE ALARMS/DETECTORS AMENDMENTS):
<br /> SHALL BE INSTALLED IN ALL lNTERNATIONAL RESIDENTIAL CODE (IRC) 2015 �
<br /> SLEEPING ROOMS, IN AREAS INTERNATIONAL FIRE CODE (IFC) 2015
<br /> OUTSIDE SLEEPING ROOMS NATIONAL ELECTRICAL CODE (NEC) 2014
<br /> AND OTHER LOCATIONS PER UNIFORM PLUMBING CODE (UPC) 2015
<br /> IRC SEC. R314 & IBC SEC. WASHINGTON STATE ENERGY CODE RESIDENTIAL (WSEC) 2015
<br /> 907.2.10. ELECTRICAL POWER CITY OF EVERETT DESIGN & CONSTRUCTION STANDARDS & SPECIFfCATIONS
<br /> BATTERY BACKUP AND
<br /> INTERCONNECTED IN ALL CODE INFORMATION
<br /> CONSTRUCTION AREAS WHERE
<br /> THE WALLS AND CEILINGS 1. SILL PLATES OVER STEMWALLS:
<br /> HAVE BEEN OPENEQ. 2 X 4 PRESSURE TRERTED PLATE, 5/8 X 10 ANCHOR BOLT WITH `� �D
<br /> CARBON MONOXIDE WASHER 2 X 2 X 3/16 Cs� 48" O.C. MAX. 12" FROM CORNER � �
<br /> . DETECTORS TO BE INSTALLED 3" X 3" X " PLATE WASHERS REQUIRED AT EACH ANCHOR u \ \
<br /> PER CODE. B O L T P E R I�C S E C. 2 3 0 5.3.1 1 � � �
<br /> � ALL OUTLETS, SWITCHES AND 2. ALL WOOD IN CONTACT WITH CONCRETE TO BE PRESSURE � �
<br /> LIGHTS SHALL MEET AND/OR 2 TREATED. .
<br /> EXCEED CURRENTLY ADOPTED 3. ALL INSULATION MATERIALS INCLUDING FACINGS SHALL HAVE � �
<br /> NEC 2014 CODE AND A FLAME SPREAD INDEX NOT TO EXCEED 25 AND A SMOKE � �
<br /> CURRENT RCW/WAC, � �
<br /> DEVELOPED INDEX NOT TO EXCEED 450. IBC SEC. 719.2 & IRC
<br /> SEC. 316.
<br /> 4. DURING ALTERATION WHERE EXISTING FRAMING CAVITY IS EXPOSED z (� �
<br /> DURING CONSTRUCTION, THE CAVITY WILL BE FILLED WITH INSULAT(ON: R15 z
<br /> IN 2x4 WALLS, R21 IN 2x6 WALLS, R10 IN ALL HEADERS, R-49 IN CEILING. � � �
<br /> � H �
<br /> 2 � �
<br /> 5. AIR INFILTRATION ALL EXTERIOR PLATES AND WA�LS WILL BE CAULKED �---� (� �--�
<br /> AND SEALED WHERE EXPOSED. �
<br /> �/
<br /> � U � � .
<br /> 6. VENT FANS SHALL TERMINATE AT THE EXTERIOR OF THE BUILDING PER � �
<br /> IMC SEG 501.2. INSULATE ALL DUCTS OUTSIDE OF CONDITIONED SPACE PER !�-� � �
<br /> � WA STATE ENERGY CODE
<br /> r,�- J c
<br /> 7. ALL SHOWERS SHALL BE FINISHED WITH A SMOOTH, NON ABSORBENT
<br /> SURFACE TO 70" ABOVE THE DRAIN PER IBC SEC. 1210.3. � `—' �
<br /> �
<br /> 8. SMOKE ALARMS/DETECTORS SHALL BE INSTALLED IN A�L SLEEPING
<br /> ROOMS, IN THE AREA OUTSIDE THE SLEEPING ROOM, AND IN OTHER
<br /> LOCATIONS PER IRC SEC. R314 & IBC SEC. 907.2.10. ELECTRICAL POWER
<br /> BATTERY BACKUP AND INTERCONNECTED IN ALL CO(�5TRUCTION AREAS � �
<br /> WHERE THE WALLS AND CEILINGS HAVE BEEN OPENED. �
<br /> 9. CARBON MONOXIDE DETECTORS WILL BE INSTALLED PER CODE. I�
<br /> 10. NEW WINDOW/DOOR GLAZING WILL HAVE A U—VALUE OF 0.30 OR � ' (� �
<br /> ' GREATER. I� �
<br /> � 11. ALL NEW EGRESS WINDOWS WILL MEET 2015 IBC REQUIREMENTS FOR � Q
<br /> EMERGENCY ESCAPE AND RESCUE REQUIREMENTS. A MINIMUM OF 5.7 SQ. .
<br /> FT. CLEAR AREA, 42" SILL HEIGHT. 0 �
<br /> � � �
<br /> 54'-10" �
<br /> �
<br /> � 38�_9�• 38'-9" EXISTING 16'-1" ADDITION � �
<br /> �
<br /> ' 10'-3" 14'-2" 14'-4" 10'-3'� •
<br /> 14'-2" 14'-4., W
<br /> �2o^w x ss^n � 0 �
<br /> O.H. DOOR �— � �
<br /> EXISTING EXISIING , , — i--�
<br /> ' 96"w x 48"h 54"w x 36"h �-- ,
<br /> 96"w x 48"h 54"w x 36"h 7� Si��O 32• LS sill� 44" I I
<br /> TS sill� 32" LS sill� 44" � I � i i i �
<br /> EXISTING EXISIING o�,�ooR � �\ � W �
<br /> 72"w x 60"h 54"w x 60"h AIR INLET
<br /> ,� 5���� 20� PORCH � QA ,� 5���� Zo• PORCH = (SEE NOTE) I $� { cz
<br /> a - � NOTE:
<br /> � o � O � � PROVIDE BLOCKING AS �
<br /> , � CL O SE T "' o���ooR A�R �N�T REa��RE�,ENTs: � C L O S E T N E E D E D S O T H p T U N I T `
<br /> — CONiROLLABLE & SECURE OPENING � ( I
<br /> BEDROOM 3 LIVING BEDROOM Z — NOT COMPROMISE THERMAL PROPERTIES � � ; � SEPARATION WRLL EXTENDS �
<br /> `' — PROVIDE 10 cfrn � 10 Pascals �—IN i
<br /> ROOIYI (EQUIVALENT 4 SQ. IN. NET FREE AREA) � I TO THE UNDERSIDE OF I
<br /> -=�,� " OPTION: MAKE UP AIR WILL BE A COMPONENT
<br /> , i�i ��, N iNFi�� �nNoow - THE ROOF SHEATHING � �
<br /> OF NEW GAS FURNACE (95Y EFS) TO MATCH EXIST. � L - - - - - - - - -- � L•
<br /> ��� x� - "' BEDROOM BEDROOM 2 W� MIN. R S 5`�� - SEE DETAII C/S2 X� � ;— o
<br /> � - ;;; M� M FOR UNIT SEPRRRTION N�, - � c� c�
<br /> DEMOLISH WALLS AS SHOWN � FIREW�LI CONSTRUC110N n� c° °�
<br /> - INTERIOR WRLLS RRE NON-BERRING � _, � ��' 8�_���� � N T � �
<br /> �M - NEW HEADERS AT OPENINGS AS NEEDED o � �M � o � �� `�
<br /> �.�,
<br /> ;° ,-'�� (SEE ROOF FRAMING PLAN FOR LOGA110NS) "' � N o� , � M `� a\-��� �
<br /> MO �� ��� I I X wr�� x n n ^ � J_ /
<br /> � �� n / „ n i I I W ° " � 30 X 80 '
<br /> � 53 X 80 � 30 X 80 � �� �� � � 53 X 80 � LIVING H� BATHROOM � � � U �
<br /> � �------= � 24 X a0 i i ' $o c�n I 3'-0" W
<br /> � -- � �====, r—� �__ � �
<br /> -,----�------i— i ,- ROOM � ,�
<br /> -------- �-----------, � T __�---- ------ -- � z
<br /> __________ , ,--- 2R �7 P.T. 2x6 LANDING � �
<br /> � CLOSET � � � � � � ��' 60" X 80" <.o � CLOSET > > � � � W
<br /> , � � � � � , ,\ N ;���,(�� RLL SD & CO O �T ��° FRAMED OVER SLAB _ o � � .
<br /> I I I _J �
<br /> �� L__� � �� DETECTORS TO BE 3 X 80" O 36" X 80" � , `� � w
<br /> � � � � ' �% � ���o" �� = FURNACE 32" X gp" INTERCONNECIED , , � � NEW CONC. o � o
<br /> � � ' � � �-----J � ���� � �-�N UTILI `� Q � 20-MINUTE RA1ED OR _ � PRD STOOP �- �
<br /> 1 I � Y ��� r----� ( ���\a�°l I � r \ � � � ,
<br /> I I � p ��� � �
<br /> � � `___�' ��.�G;�' � � � � � � ; "' W.H. ROOM M PANTRY i � � � �o � � � �
<br /> � a� 1 g MIN, SOLID WOOD � o 0
<br /> __ ; � �U L j � � F,� L_ RLL SD 8�C0�� ^� DOOR w/ SELF-CLOSER �
<br /> `_ I I I I I I I ro�i �O�n X UO„
<br /> DETECTORS TO B Q °-
<br /> jI I I I I I "� „ ��N °a ' ^
<br /> , , � , ,,, _� ,n � ,.� � INTERCONNECTED . .
<br /> KITGHEN � � BAIHROOM i i BEDROOM �1 �i� �o � � D W M ,���� o 0
<br /> 0
<br /> ii ii , ' — �
<br /> ,'�� i i i i i i � p `t
<br /> . UTILITY ,'� „ „ i�'`�, � � i � ; i �n LAUNDRY � o
<br /> ROOM � 30 X 80 ;; � �, � � � � � ; ROOM � ,
<br /> , �______� �� � � � � � � � , t5��, FRIDGE � n n I
<br /> ` ;; � `� � �I � � � ; W.H.F. 36 x 32 " 28 X 80
<br /> �_-__T___-___i__'____-- I L__T�-__T--J L-------------r------r---------� � O �" 1`Gi7 O
<br /> � __
<br /> ,-_ BATHROOM � � ' W L�
<br /> . L____-______�_________________-______'_________�_____�__________� AL—� z z cv
<br /> 32��w x 48"h 32"w x 36"n 24"w z 36"h 30"w z 48"h EXISTING ��(y � x CLOSET � ACCESS � � � •
<br /> DH sill0 32" DN sill@ 44" DH siil0 44" DH sill0 32" 32��w x 48"h � ` �
<br /> oH 5���0 3r °� 80`M M � WELL PER � u � �r
<br /> �0'-2�„ 2 8'-s2» � DW } F D N. P L A N � � � �
<br /> 2 z �.�, j Q i
<br /> o �
<br /> 0 o � Z • � 3
<br /> r= _ �, � �1 N T I�
<br /> o A DINING � -� R2 � � � � �
<br /> � � �2 ROOM KITCHEN � g j �
<br /> = c'� �
<br /> � � � o
<br /> � 4 � � � � � �
<br /> ' � " �
<br /> ;D (/) ��-� �
<br /> ' , l�
<br /> " ' ouTnooR � z
<br /> � 72"w x 60"h 72"w x 60"h ^ � pH sil1�436h (IR INLET � H
<br /> TS sill� 20" Q TS si110 20� NEW CONC, O SEE NOTE) ;. N �
<br /> ZO TEMPERED GLAS5 pAD STOOP ;r, BEDROOM 1 � �
<br /> H � �
<br /> �
<br /> Q 4'-0"
<br /> �,N D � TE �
<br /> �
<br /> � � / 2g / 2016
<br /> � /+ 96"w x 42"h
<br /> ' �� TS sill� 38"
<br /> � g'_g" 28'-7" ADDITION 16'-6" ADDITION � � � � � `
<br /> � �,
<br /> - - 1 „ _ 1 , _ � „ .
<br /> 4 —
<br /> D EM 0 �1 TI ON M AI f� ��OOR P �A �l P R OP OSED M AI f� ��OOR P � AN
<br /> SCALE: �" = 1 '-0" SCALE: �" = 1 '-0"
<br /> - ' SHE � T �
<br /> -, ,.
<br /> �I�RTH - _
<br />
|