� STAi�IP: <br /> CL SUPPORT CL SUPPORT CL SUPPORT <br /> � <br /> I � � �AV D S <br /> I L � <br /> TENDON SHALL ��'��'o� W'S�I����� <br /> TENDON SHALL REMAIN STRAIGHT � �� � �� <br /> REMAIN STRAIGHT � , <br /> 1'-3�� 33253 <br /> 1'-3" PROVIDE �4 x 3'-0" TOP AND BOT OF o�, UCTU� � <br /> ADDED TENDONS ADDED TENDON ANCHOR �0� sTR �ti �' <br /> � (SEE PLANS) � �sS10NAL ��l . <br /> � � � � w� <br /> �, NOTES: <br /> , 1. BOTTOM BARS AND STUD RAILS ARE NOT SHO'NN FOR ['ROJECT: <br /> `� `� GLARI I Y. \ <br /> � � w w _ 2. SEE PLAN FOR TOP AND BOTTOM SLAB BARS. � ESF F1�CILITI�,S <br /> TENDON DIM FROM BOTTOM OF 1 6 �, 1 6 , 3. PROVIDE (2) �7 SUPP�RT BARS AT BANDED TENDONS. MAX � � ���AIL <br /> �� STR. PRO;FILE OF SPACING 3'-S". USE �4 SUF'PORT BARS AT 3'-6" OC <br /> SLAB HIGH AND LOW POINTS TENDO�JS AT BAND AWAY FROM COLUMNS AT BANDED TENDONS. <br /> ARE NOTED ON PLANS. DIM <br /> WALL, COL OR BEAM SHOWN ARE TO CG OF TENDON ' I ' 4. PROVIDE �4 CONTINUOUS SUPPORT BARS AT 48" OC AT E���E� <br /> AS INDICATED ON PLANS COL PER PLAN WHERE � ; DISTRIBUTED TENDONS. <br /> , (TYPICAL) CONTINUES ABOVE FLOOR. —'— 650=k EVEEZGREEN WAY <br /> �� 2 STRANDS (MIN) TO PASS EVEEZE�IT, W�1 98203 <br /> SEE PLANS FOR � ��� DIRECTLY OVER COLUMN IN � ' <br /> REINF AND PRESTRESS � EACN DIRECTfON �� <br /> CANTILEVERED SLA� � � <br /> EXTERIOR SUPPORT INTERIOR SPAN INTERiOR SUPPORT INTERIOR SPAN o00 0'0 000 � � P1�Z1�N � <br /> � � � <br /> � NOTES: � � � 1 1��OCI���� <br /> � 1. SEE PLANS FOR TENDON LAYOUT. � � �RCHITECTS� INC. <br /> 2. TENDON LOW POINTS ARE MIDWAY BETWEEN HIGH POINTS, UNLESS NOTED OTHERWISE. COL CJ SHALL BE AT SLAB <br /> 3. TENDON LOW POINTS AT EXTERIOR SPANS ARE LOCATED 0.4xL FROM CL OF EXTERIOR SUPPORTS. SOFFIT. COL OVERPOURS SEE COL SCHED � <br /> 4. DRAPE TENDON IN PARABOLIC PROFILE BEfWEEN LOW AND HIGH POINTS. SHALL BE REMOVED DOWN TO FOR REINF 2000 - ll6'Ill-1 AVLN�[E NE <br /> 5. DROP PANELS, WHERE THEY OCCUR, ARE NOT SHOWN FOR CLARITY. SLAB SOF�IT SUITE '� � <br />� � � BELLEV�IF, WA 9800� �� <br /> � �2�.637.083 t � <br /> � <br /> SEE SCHED � Ff\X.637.1878 <br /> � � NOTE: <br /> TYPICAL SLA� COLUMN INTERSECTI�N � '' ������c�"���c�. <br /> TYPaCAL POST—TENSION TENQON LAYOUT � „ , „ � ��„� ,�,D� �,��„� <br /> SCALE: 1/4" = 1 '-0" SCALE: 3/4 = 1 -0 IAECHANICAI� PLU�I�ING, <br /> Ei�C1RICALo AND F1RE <br /> � PRO�C710RI� S`FIALL � U� IN <br /> �. COL OR WALL � C0� � ��N��E 1F) �IlEC�l1R� � <br /> � � CONIRAGTOR SHALI. VE1dIFY AND <br /> 2'-0" 3'-0" SEE PLAN 1:6 MAX 3'-6" � (:Q�DIPIA�E QI�ENSIONS ��iG <br /> L/5 STRAIGHT MILD REINF TO BE DISTRIBUTED �� 11L1 DRAWIN�.S. AtdY C�ION <br /> D�St�AfdqES, CONTRADI S, <br /> WITHIN THE DIMENSION LWES 1.5H W 1.5H � �Il��IS �IALL � <br /> EACH WAY MILD REINF TO BE DISTRIBUTED REPOR7ED TO 1HE ARt�°IiTECT F� <br /> NJITHIN THE DIMENSION LINES n� �� � �G <br /> ,,,,,,,,, „ �,,,,,,,,, ,,,,„ „,,,,,,,,,,,,,,,,„,,,,,,,,,,,,,, ,,,,,,, �Z}i OR F CA1l�+i � <br /> � DISTRIBUTED TENDONS �, TOP REINF PER PLAN EACH WAY <br /> ,„,; , „ ,,,,,,,�,,,,,,,,,,,,,,,,,,,,,,,,,, (6T OR 48" OC MAX 1HE I1D�(S) iN �1E5"il�+l. <br /> \ 2. NOT A FUIi �� DRA�NG U�l.ESS <br /> SPACING TYPICAL) REINF I— � DISTRIBUTED TENDONS O PRINTED OPI 24� x 36" SFIEE7. IF <br /> �iii iiiiiii�i iii. ;ii iiii, �iiiiiiiiii�iiii ,ii iii ;iiiiii I�iiiiiiiiiiiii�i��ii� N � <br /> �� COLUMN � ���� ������ ���������������� �������������=���������������������- � (SEE PLAN) TYPICAL MILD REINF� � (6T OR 48" OC MAX 1HIS �IEET IS NOT 24' x �° <br /> w STAGGER EACH WAY 12�� SPACING TYPICAL) 1HEN IT 1S NOT TO SCALE. � <br /> ' Z �ii i i iii fiii �ii iiii i, iiiiiiii�i iiiii,�iiiiiiiiiiiiiii iiiiiiiiiii i iiiiii� Z <br /> � o #4 AT 12" OC � "' <br /> � � � �i�iiiiiiiiii;iiii�i�ii�iiiii �..�.. � ...iiiiiiii,iiiiiii. J � � � . <br /> O p <br /> � o � o WHERE THREE OR MORE SINGLE � f� ,, ,,.� �,, , �,,� ,.-,� ,„�,�,��,�,(,,��,,,,,� � - - � � - � �— 3° OC TYPICAL (WHERE SLAB IS 8" THICK `� <br /> W � m CONDUIT OCCUR, PROVIDE REINF � i " z � � , OR LESS, USE 8" OC AND TURN ANCHORS 90°) � <br /> � � ���,� � ��,����������������� ��. ������; „�;��, ¢ <br /> Q o c�i� FOR CONDUIT GROUP. (3� CONDUIT I m � __ � OR AS REQUIRED BY THE POST-TENSIONING r -- � <br /> o � MAX IN EACH GROUP ,,,,,,,,,,,,, , ,,,,,,,,,, ,,,, ,,;,,,,,,,,,,,,,,,,,,,,,,,, , ,,,,,,,, ,, ,,, ,,, SYSTEM � . <br /> J ___ __...__-_.-_ <br /> i i � <br /> � Q � , ._ ._" - \\ <br /> �i !iiii�iiiiiiiii�i�ii iiii� iiiiiyiiiiiiii:i ii,i i iii. � <br /> � � <br /> W <br /> �. � � � � � � � iiii iii:ii�iii .iiiiiiiiii, �ii i� iii;i iiii,�iiiiiiii i iiiiiiiiiiii iii i v iiiii. _ . <br /> _ °- '-� �� RE�'I�ION�: D�\TC- <br /> " � EXTEND NEGATfVE � � <br /> � , ,�,,,,,, ,,,,,,;,,,, ,,,,. ,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,, BANDED TENDONS (4 PER <br /> , MOMENT REINFORCEMENT _ - <br /> �� PAST DEADEND ANCHORS � ����� ���������� �-, ,,�,,,,�„ � ,,,,, ,,,,, ,,,,,,,,,,,,��„�-�-������� BUNDLE TYPICAL) —A MINIMUM OF (3) TENDONS AT SLAB MILD TOP REINF 12" OC MAX � � � � <br /> � <br /> CONDUIT 1'-0" 1'-0" H/6 DIA 2 5 TDNDONS RONLYL TO DISTRIBUTED BANDED BUNDOE TYPICA) (TYP PER PLAN) <br /> � ) � WIDE SHALLOW PT � CITY UPDATES 10 13 17 <br /> DIA MIN MAX (TYP) <br /> NOTES: � <br /> BEAM, WHERE I I6" NOTES: 1. A MINIMUM OF 2 TENDONS TO `� <br /> OCCURS (SEE PLAN) '�`- 1. A MINIMUM OF 2 TENDONS TO <br /> NOTES: PASS DIRECTLY OVER COLUMN <br /> PASS DIRECTLY OVER COLUMN <br /> NOTES: 1. TRANSVERSE PRESTRESS AND MILD REINF NOT SHOWN FOR CLARITY EACH WAY. EACH WAY. � <br /> 1. CONTRACTOR SHALL SUBMIT SHOP DRAWINGS INDICATING 2. DEADEND PRESTRESS SIMILAR IN TRANSVERSE DIRECTION 2. LEGEND <br /> 2. LEGEND `� <br /> PLACEMENT OF CONDUIT IN PT SLAB. SEE GENERAL NOTES. 3. TENDON PROFILE AT DEADEND IS ONE-HALF SLAB THICKNESS T: SLAB THICKNESS � <br /> H: THICKNESS OF SLAB OR <br /> (UNLESS NOTED OTHERWISE) W: COLUMN WIDTH � <br /> 2. CONDUIT PLACEMENT NOT MEEfING THIS CRITERIA SHALL BE SLAB PLUS DROP PANEL. H: DEPTH OF SLAB AND DROP • <br /> SUBMITtED TO ENGINEER FOR REINFORCING DESIGN. W: COLUMN WIDTH PANEL <br /> 3. DO NOT PL4CE CONDUIT WITHIN 3'-0" OF COLUMN FACE. T: SLAB THICKNESS <br /> " 4. 'H' THICKNESS OF SLAB. . <br /> TY�ICAL CONDUIT PLACEMENT CRlTERIA TYPICAL DEADEN� PLAN DETAIL TYPICAL REINFOR�ING AT E�TERIOR SUPPORT 5 TYPICAL REINFORCING AT I�VTERIOR SUPPORT 6 <br /> SCALE: 3/4" = 1 '-0" 3 SCALE: 3/4" = 1'-0" � SCALE: 3/4" = 1'-0" SCALE. 3/4" = 1'-0" <br /> �R��v� ��� � <br /> , � <br /> CHECKED BY <br /> � <br /> ['EZQJECC# �� <br /> SET ISS�IE DATE: �/'�/�� <br /> � St-IEET-CI-CLE . <br /> , � � <br /> � <br /> � �� � ��� l�� . <br /> � ��� <br /> � �� <br /> SHEET# <br /> PSM CONSULTING ENGINEERS, INC. <br /> � <br /> 2200 SIXTH A�/ENUE, SUITE 601 � � <br /> SEATTLE, WA 981 21 <br /> P: 206.622v4580 F:206.622.0422 <br /> � www.psm-engineers.com � . <br /> . � <br /> � <br /> � <br /> � <br />