Laserfiche WebLink
� ' 2006 Wa��'�glon State Nonresidential Energy Code Compli�nce Form <br /> � • � t . <br /> • � <br /> 'a0�WaS��n�:o^�Sld'e Nonresbenl�d�ErM'Oy 6o0P Lo'IT.I��a^Ce foTt Rev6ea Ju'�! <br /> ProJectAddress corcnn+irr HEhLYNO�AE Fcncnu CItEDI4 VNION Date 12/8/2009 <br /> Space Heat Type O <br /> Eleciric resistance Q All other For Buildmg Depariment Use <br /> Glazin Al'e8 as°/gross erterior wall area 16.Se Prop. 45.OR Maz Target <br /> Concrete/Masonry Option Ores O No � �� (Z"VU c� <br /> Notes:If glazing area exceeds mazimum allowed in TaCle.then wlculate adjusted areas on back(ovet). <br /> Building Component Proposed UA Target UA <br /> List comoonents b assembl ID 8 paoe# U-factor z Area(A) =UA(U x A) U-factor x Area(A1 =UA IU z Al <br /> U= PIanID: 0.550 755.1 615.3 0.550 755.1 615.3 <br /> U= Plan ID: Glizing°�b Electric Resist. Other Heating <br /> � o, U= Plan ID: 03D°k 0.40 0.55 <br /> �H U= Plan ID�, >30-05% see note above OAS <br /> m <br /> >c� U= Plan ID�. <br /> U= Plan ID <br /> U= Plan ID�. <br /> � U= Plan ID: <br /> 0.700 <br /> a �' U= Plan ID: Glazing°i6 Electrie Resisl Other Heating <br /> ` a 0•30% 0.6 0.7 <br /> � `m U= Plan ID: <br /> c� O �= Plan ID: >30-05% see note above 0.6 <br /> a <br /> 1° m U= Plan ID: <br /> v <br /> v °o U= Plan ID: <br /> O t U= Plan ID: <br /> � U= Plan ID: o.7oD <br /> d U= PIanID: 0.600 <br /> _ '" Eledric Resist. Other Heating <br /> a o U= Plan ID: 0.60 0.60 <br /> O� U= Plan ID� <br /> R= PIan10: 0.036 <br /> � � <br /> o > R= Plan ID: EleIXric Resist. Other eating <br /> �O 0.031 0.036 <br /> R= Plan ID: <br /> R= PIanID: 0.046 3970.0 182.6 0.046 3970.0 182.6 <br /> t� R= Plan�D: Eleclric ResisL Other Heating <br /> �� R= Plan ID: 0.034 0.046 <br /> R= PIanID: 0.109 3822.0 416.6 0.109 3822.0 <16.6 <br /> R= Plan ID: �� <br /> '" R= Plan ID: �� <br /> � R= Plan ID: Electric Resist. Other Heating <br /> � R= Plan ID: Frame-Wd 0.062 0.062 <br /> � Frame•MII 0.062 0.109 <br /> oR= Plan ID: <br /> R= Plan ID: ass Wall� 0.15 0.15 <br /> "Note:sum of Target Areas here should equal Targel Opaqne Wall Area(see back) +�see mass wall Crileria <br /> R= Plan ID: <br /> o D R= Plan ID: Electnc Resist Other Heahng <br /> � R= Plan ID: Int Ins 0.062 0.062 <br /> m c7 <br /> Note�. it insulaled to levels required for opaque walls,list above wiih opaque walls Exl Ins �.07 O.Oi <br /> v R= PIanID: 0.056 <br /> O 9 R= Plan ID: Electric Resist. Gther Neating <br /> � � 0.029 0.05u <br /> o � R= Plan ID: <br /> �= R= Plan ID� <br /> R= PIanID�. 0.5a0 <br /> `o ^' R= Plan ID: Eleddc Resist. Olher Heating <br /> 0 <br /> m o, R= Plan ID: F=0.54 F=0.54 <br /> � R= Plan ID�. (see Table 13•1 for radiant floor values) <br /> 'For CMU walls,intllcate core insula6on material. Tolals 8547.1 101a.5 Totals 8547.1 3014.5 <br /> To comply: 1�Proposed Total UA shall not ezceed Target Total UA. , 1 <br /> 2)Proposed Total Area shall equal Target Total Area. �. I l 1 I <br /> \,� , <br /> 1 <br />