My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
4727 EVERGREEN WAY B 2017 Plans 2022-11-28
>
Address Records
>
EVERGREEN WAY
>
4727
>
Plans
>
4727 EVERGREEN WAY B 2017 Plans 2022-11-28
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/28/2022 9:39:08 AM
Creation date
12/19/2018 11:29:43 AM
Metadata
Fields
Template:
Address Document
Street Name
EVERGREEN WAY
Street Number
4727
Unit
B
Permit
B1705-066
Year
2017
Notes
TI FOR NEW TENANT
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
14
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
� <br /> C405.2.1.1 Occupant sensor controi function. 4. Have program back-up capabilities,which � <br /> Occupant sensor controls shall comply with the prevent the loss of program and time settings �`` <br /> following: for at least 10 hours,if power is interrupted. ' ' <br /> 1. Automatically turn offlights within 30 5. Include an override switching device that . <br /> , minutes of all occupants leaving the space. complies with the following: � <br /> 2. Be manual on or shall be controlled to 51 The override switch shall be a manual <br /> automatically turn the lighting.on to not more control. <br /> than 50 percent power. <br /> Exception:Full automatio-on controls shall 5.2 The override switch,when initiated, <br /> be permitted to control lighting in public shall permit the controlled liDhting to <br /> conidors,stairways,restrooms,primary . remain on for not mare than 2 hours. <br /> building entrance areas and lobbies,and areas 5.3 Any individual override switch shall <br /> where manual-on operation would endanger � control the lighting for an area not larger <br /> the safety or security of the room or huilding . than 5,000 square feet(465 m ). <br /> occupants. Exceptions: <br /> 3. Shall incorporate a manual control to allow 1. Within malls,arcades,auditoriums,single <br /> occupants to turn lights off. tenant retail spaces,industrial facilities and <br /> arenas: <br /> C405.2.1.2 Occupant sensor control function in l.l. The time limit shall be permitted to <br /> warehouses.In warehouses,the lighting in aisleways be greater than 2 hours provided tha <br /> and open areas shall be controlled with occupant override switch is a captive key <br /> sensors that automatically reduce lighting power by device. <br /> not less than 50 percent when the areas a're 1.2. The area controlled by the override <br /> unoccupied.The occupancy sensor shall control switch is permitted to be greater than <br /> lighting in each aisleway independently,and shall not 5,000 square feet(465 mZ),but shall <br /> control lighting beyond the aisleway being conirolied not be greater than 20,000 square feet <br /> by the sensor. (1860 mz). <br /> *� C405.2.2 Time switch controls.Each area ofthe 2. Where provided with manual control,the <br /> building that is not provided with occupant sensor following areas are not required to have , <br /> controls complying with Section C405.21.1 or digital light reduction control: .. <br /> timer switch controls complying with Section C405.2.6 2.1. Spaces that have only one luminaire <br /> shall be,provided with time switch controls complying with a rated power of less than 100 <br /> with Section C405.2.2.L r watts. <br /> 2.2. Spaces that use less than 0.6 watts per <br /> t Exception:Where a manual control provides light square foot(6.5 W/mz). <br /> e reducfion in accordance with Section C405.2.2.2, ?_3. Corridors,equipment rooms,public <br /> . automatic controls shall not be required for the lobbies,electrical or mechanical <br /> o following: <br /> rooms. <br /> 1. SZeeping ttnits. <br /> 2. Spaces where pafient care is directly provided. C405.2.2.2 Light reduction controls. Spaces <br /> 3. Spaces where an automatic shutoff would required to have light reduction controls shall have a <br /> endanger occupant safety or security. manual control that allows the occupant to reduce the <br /> 4. Lighting intended for continuous operation. connected Iighting load in a reasonably uniform <br /> 5. Shop and laboratory classrooms. illumination pattern by at least 50 percent.Lighting <br /> reduction shall be achieved by one of the following <br /> C405.2?.1 Time switch control function.Each appy�oved methods: <br /> space provided with time switch controls shall also be 1. Controlling all lamps or luminaires. <br /> provided wifh a manual control for light reduction in <br /> accordance with Section C405.2.2.�.Time switch 2. Dual switching of alternate rows of <br /> confrols shall comply with the following: luminaires,alternafe luminaires or alternate <br /> 1. Have a minimum 7 day clock. lamps. <br /> 2. Be capable of being set far 7 different day 3. Switching the middle lamp luminaires <br /> types per week. independently of the outer lamps. <br /> 3. Incorporate an automatic holiday"shut-off' 4. Switching each luminaire ar each lamp. <br /> � <br /> feature,which turns offall controlled loads for Exception:Light reduction controls are not {' <br /> at least 24 hours and then resumes normally required in daylight zones with daylight responsive (� .�� <br /> scheduled operafions. controls complying with Section C405.2.4. ,�� <br /> a� <br /> CE-76 2015 Washington State Energy Code � <br />
The URL can be used to link to this page
Your browser does not support the video tag.