Laserfiche WebLink
. rr,--�-� f,.. ...1 <br /> , f-...� ..�4'' s,..l :�'�, <br /> -_.> ��..� ��.�? �� E G E N D <br /> `...�.f.-�' ::�' <br /> � <br /> � 1 �" DRAIN LINE RUN HIGH AND THEN DOWN <br /> DIRECTLY ABOVE FLOOR DRAIN. SUPPORT 1�" <br /> DRAIN LINE FROM TRUSSES AND FLOOR <br /> ; <br /> � MTD. SUPPORT ADJACENT TO FLOOR DRAIN � . <br /> E � <br /> � M 630 � <br /> � <br /> ; 3 2 �" BACK FLOW . <br /> M651 PREVENTER WITH <br /> 6" CW „ FULL SIZE RELIEF G E N E R A� N 0 T E S <br /> TO FLOOR DRAIN <br /> ' - SEE SITE DWG � <br /> � HW " VE T UP ��- —�\ <br /> i �� 6" VALVE �a 3" 2 i � � ULTRASONIC FLOWMETER FUJI MODEL � <br /> ;�........`._.......__�_�___� IN RISER � � ..�. .. ..... __..�._. .�._..........._................. FSVEYY41 —SYYYB—N <br /> �.�.....�._ ..__..._ <br /> ,......_.. : ;_..:.........�..._�..�. ..�.. ..._....__ ----- .... ..... v ..........�.,...._.�.......................................................... <br /> ; ,� ,-x._:=�::=-...�-. _::�::. .».� � � <br /> .... , , v�.�..........._...�..�;, .� W_. 3, -... <br /> �� � � <br /> e � <br /> -Bf <br /> 1 ° ��'; _:................��------.--................. ....�...._....---...........�............�.........__----------...... .�_....,...._..._...y.1-�--�------.....�..._.....-��---. ....... _.............----..... . �� j...... .... 3 ...... ...�� � '' <br /> ��_. _ .. .� ...�. <br /> , .�, _.._--- ,��-- ------- ---. ...... .......^- -�� <br /> -"� DROP OFL ALONG %; : <br /> °.. � .�}� , ; .... ... ... ............_ . .. / . ...... ... Wi�L:C...7�ID....��N�l`f�i'Y`��".. : �, l 1 <br /> � --- - <br /> �.._._.. ; �`... WALL 18' AFF. IURN ``�._ _f�` <br /> � 6 SAN j � 6 M W2�n �� 1 I �� � � 3' OFL DN 45' 3� SEE DWG. 40-056—M462 FOR ROUTING OF <br /> w � � • <br /> IE 534.50 � 3 ' � �—' OUTSIDE OF WALL DRAIN PIPING TO FLOOR DRAIN. <br /> TO MHW-7 E �' � 3" RD— 3 0�_� 4� SEE DWG. 40-056—M463 FOR ROUTING OF � <br /> IE 534.50 � '3 € IE 534.72 �„ P �� . �-2 0 704 SQ.FL � ' � <br /> SEE SffE DWG P P I E 5 3 5.3 2 DRAIN PIPING TO FLOOR DRAIN. <br /> � FOR CONTINUATION �....... .-.��...-�-.�. � <br /> ; ; <br /> - ; <br /> . ._.... � <br /> E - ; 5� SEE DWG. 40-056—M462 FOR PROCESS WATER <br /> ` � ` " PIPING TO VACUUM PUMPS. <br /> € � <br /> e : � E � i <br /> � ;% ' .._�.........,...» » .. <br /> � ;; ; 1 <br /> 6� SEE DWG. 40-056—M463 FOR PROCESS WATER <br /> � ; PIPING TO VACUUM PUMPS'. <br /> I € � <br /> � <br /> ; . � <br /> ,�........ .�........_�..�_............_........_ <br /> i i � ( <br /> , € � � � <br /> � <br /> ; ; ; � <br /> : : ; . <br /> � � ` ` y 3 <br /> ; : , � � . <br /> / r ; $ i <br /> i . <br /> % % �.......... .....�.. ........ .� ,........ . 3 . <br /> � E �"� 3 <br /> � <br /> , E � <br /> � � RE �ERENCE DRAWI �IGS <br /> ` 1�" GALY. STE D ' � <br /> ' ` UNE. SLOPE �' PE ; � � <br /> 40-056—M462 ENLARGED PLAN — NORTH VACUUM <br /> �� ` � ! PUMP ROOM <br /> f RUN 1�" DRAIN LINE HIGH ; � ;' 40-056—M463 ENLARGED PLAN — NORTH VACUUM <br /> � �3 � AND DROP DN DIRECTLY : - ; <br /> .._._........._........ ....._�..._......_.........< <br /> ! ' I ABOVE FLOOR DRAIN. PUMP ROOM ADDITION � <br /> SUPPORT 1�" DRNN UNE _ <br /> ' FROM TRUSSES AND FLOOR ; � <br /> MTD. SUPPORT ADJACENT TO � <br /> ; : FLOOR DRAIN. � � <br /> . € € '�.�.�.;�.��.��a� �''E��.,�N,, : co <br /> � � ��,..j � B <br /> . E 3 , i �1;_�5,���� ' ' <br /> , � 3: j . , . - - - - i � . <br /> : <br /> : �� ` i I " ��� � � , , I <br /> :__ <br /> � '� : :..�.......----�..-..m..----. DIELECIRIC UNION FCO a <br /> �-------- C 0 N STR U C 0 �l N OTES <br /> , : � � � � <br /> � 1�j REMOVE EXISTING PROCESS WATER COOLING PIPING <br /> � : , " ; BETWEEN POINTS OF CONNECTION AT NORTH WALL <br /> � E ___Y...._. �W AND AHU COOLING COIL. REMOVE AS MUCH OF THE . <br /> ! j � � 6 ,L DN � 5408 �; � EXISTING PIPING TO COIL AS POSSIBLE AND <br /> � ;; ` . ; . ffH CO AT ; � ,�, REPLACE WITH NEW. COORDINATE WITH NEW WORK. <br /> ` ;' � f BASE CONT'D. ' w - <br /> IE 542.50 `�' <br /> � z 2�'j REMOVE ABANDONED PLUMBING FOR SINK AND <br /> . , 4 : � � WATER HEATER (NOTE SINK HAS ALREADY BEEN <br /> ; € � � 3 � ! z R E M O V E D). C U T O L D D R A I N, C A P, A N D R E P A I R <br /> ; �. � � :�..�.............._-----------........�...._.._IXP. ; ,- FLUSH TO FLOOR. <br /> �`� � � ` ; `� � z <br /> � E O <br /> : € ; ; : <br /> °�==�;'--,--�::--.�%� : E i I ` <br /> � ; � : � �....................................�-----�-�--------------f � " � <br /> ' � I � � <br /> �`�W..� � � � � <br /> : I w <br /> i � � � � z <br /> � f i � �..............._,......._.,................__....._..., � � <br /> � i € � � � � � ; I U <br /> . : ; � : Q <br /> � � �.......................�.....� � <br /> - � � � y IE 53 .50 ; <br /> � ; '; � � i j <br /> , <br /> � ; � � � 3" 0 DN, TERM. 0 FCO I <br /> � � 18" OVE GRADE WRH I � <br /> : � A 45' F�11NG OUTSIDE ; � 6�°I <br /> ` ' OF W : ; I � <br /> , � ' i <br /> � � � i 3 �RD-1 0 , <br /> : , <br /> � � (�/� .��.�,..�,.� <br /> � € @ � E # _... ���4 JV(. .3��i f � �=�=�'�-�"=�'==g- . <br /> ` � � ' � 3" DN 3» R�-1 � B ' .;,� ' ->.� ; . <br /> , <br /> - ., <br /> ; <br /> � t ; � E i <br /> �w'"� i E ' <br /> ,, f <br /> , � E , ' ; <br /> r , .m.,, _.. <br /> � w...... ._ � .......�.....-�---�-----..� ._ �_,_._,,, <br /> w� e � �w.�_.�...__�_..�. _� u.�., .....��, ; .�...;�� ------- _.....����.:�..---...... -�....�.�._ _.�......_.�. �� DD CC C G L Q S. <br /> ------.. _�...,.,.�.....t..-------s <br /> `�-,......,-� � . . ----._. �....._���...�...,�....._;...... ; ......._.�.......... ..._......_. .....�.....�.....�....__.�.........�... <br /> , ; � <br /> . � �� : � I U � <br /> `a 7 �0. <br /> � �`E,.�..,..� I � i 6" VENT I U � �0 <br /> � � , I � 6'1fTR � � 0 10 11 12 13 14 <br /> ` ' ' � 4 I g <br /> � ; :. : ( TYP. � C.I. TO PVC � 15 16 17 18 19 <br /> �' � ' I �1DAPTOR (TYP) 8 <br /> � �� ; _ � 6� �w _.° ; N 20 21 22 23 24 ' <br /> ; , � � I� 543.00 7 <br /> ; , �____�_��._... <br /> �....�,., ; ;� � .�; �. _ <br /> ... <br /> : ;E � i . 28 <br /> _ , . <br /> : <br /> � , � : � �� — _..._............- ---... .--��..�.._.._._.._._......_ . <br /> : �+�+[�� <br /> , ���... .: <br /> . . <br /> , �-� ` E � ' � � � �`��-%� <br /> ; _� <br /> ; . <br /> ....................._............._..._ _��_�____.._........ ....• . <br /> ; <br /> r ....._...,........ �, I JJLn � � <br /> y � � .... `: ; 2' NENT UP ; .� �' � 1 30 31 32 33 34 6 <br /> �-- M A� I� L I N E � F O R C O N T I N U A T I O N S�E���#��fi������1�-1��1��1�0—1 5 a � � 3» � �.. �F�-�-�" s <br /> . . a:� . E � <br /> � 35 3 6 37 38 3 9 <br /> 4 <br /> 40 41 42; 43 44 <br /> 3 <br /> P A R T A L P LA N �I E W y a 45 46 47 4$ 49 <br /> � I z <br /> SCALE: 1/8"=1 '-0" I v � �,� ,�,�,,.� ��6 50 51 52 53 54 <br /> � g� � i � <br /> GROUP 55 <br /> 600 Stewart St., Ste 1400 K EYP LAN <br /> , Seattle, Washington 98101 SCALE: NONE <br /> . � ISSUED FOR PERMIT <br /> �; Tel 206.267.1700 g� 4° 0 4,' 8' 16' <br /> �7. � 8. � 7 Fax 206.267. 1701 <br /> SAZAN # 500-1775 <br /> SCALE: 1/8"=1 '—0" <br /> SYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE a ACCEPTABILITY DRAWN DATE SUBTITLE CURRENT REVISION SYMBOL DATE , <br /> �� ���1�; THIS DESIGN AND/OR CHECKED PLUMBING PLAN - FIRST FLOOR W2572915 B o�.18.17 <br /> — WATERMETER INSTALLATION 8632018 RDN DH/FB 06.08.09 ��� oF �va�l,,� t <br /> � � , ��-;��� SPECIFICATION IS APPROVED SHEET <br /> , r.�� Z�i� � N W TITLE <br /> A IRC — WBS 2.2.3.3.2 HD VACUUM PUMP RM— RECORD DWG W2572915 SAZAN KLW 07.15.16 � � ' `��;p, �b � zr� ,aPPRovEo BY DEPT. DATE IRC — WBS 2.2.3.4.4 ROUTER VAC PUMP H20 RECYCLE � <br /> B I R C — W B S 2.2.3.4.4 R O U T E R V A C P U M P H 2 0 R E C Y C L E W 2 5 7 2 9 1 5 S A Z A N KL W 0 7.18.1 7 BOE,�� r..� �� ��� r���,;�,� ��f�...,;, CHECKED 1 M <br /> , F ;_ � 110R 10a <br /> j13�' ' BUILDING 40—�56 <br /> , `���',�FCI�TERFV �,`��,� <br /> �oe No. W2572915 COMP N0. <br /> �sslo�a���' APPROVED <br /> • 07/17/2017 APPROVED MECHANICAL MASTER COL. DD—CC/9-10 EVERETT, Wq owc No. 40-056-1 M 110R-10a <br />