. INSTRUMENT IDENTIFICATION PIPING SERVICE DESIGNATIONS
<br /> LETTERS OR COMBINATION AH AL C CV E Y I IC IT Q QIS R RC S SH SL T V W
<br /> OF LETTERS USED A - COMPRESSEQ AIR CRV - CORROSION RESISTANT-VENT HYDS - HYDRAULIC SUPPLY (1500 PSI)
<br /> �
<br /> BBD - BOILER BLOW DOWN CRW - CORROSION RESISTANT-WASTE IA - INSTRUMENT AIR
<br /> � � BFW - BOILER FEED WATER CTWR - COOLING TOWER WATER RETURN IW 1 - INDUSTRIAL WASTE
<br /> ^ o � C - CONDENSATE RETURN (GRAVITY) CTWS - COOLING TOWER WATER SUPPLY IW2 - INDUSTRIAL WASTE
<br /> _ � � � � z ,� w o = � � CAOH - LIME SLURRY CW - COLD WATER, DOMESTIC LPC - CONDENSATE (LOW PRESSURE)
<br /> � �' o � Q � ,? �- � � z z `�' _ � � Q CAU - CAUSTIC DEV - DEVELOPER LPS - STEAM SUPPLY (LOW PRESSURE
<br /> � = J W i� Z p � W � � C.`� W � •
<br /> �-- J o o � c.� c.�►- o--� o � z , i �- CD - CONDENSATE DRAIN DF - DIESEL FUEL 0-15 PSIG)
<br /> � � � o o �' >- L'� o z z � c_,,N c� o o � J MPC - CONDENSATE (MEDIUM PRESSURE)
<br /> . � � � � �! Q �w c Q Q c�r� �, J = � � _ _ = c�n � CF- 1 - CHEMICAL FEED DI - DEIONIZED WATER
<br /> � � � z z J � Q z " `=' �' z �� c� o � � � � z �- -� MPS - STEAM SUPPLY (MEDIUM PRESSURE .
<br /> ,� PARAMETERS Q Q o o� � �o � � � � �� m � � � � � � o � CF-2 - CHEMICAL FEED FW - FILTERED WATER 15-125 PSIG)
<br /> - - CF-3 - CHEMICAL FEED G - NATURAL GAS PC - CONDENSATE PUMPED
<br /> A ANALYSIS AAH AAL AC ACV AE AI AIC AIT AR ARC AS ASH ASL AT AC CLV - VACUUM, CHIP COLLECTION HNO 3 - NITRIC ACID PENT - PENETRANT
<br /> B BURNER, COMBUSTION CHWR - CHILLED WATER RETURN HPW - HOT PROCESS WATER
<br /> C USER'S CHOICE PW - PROCESS WATER
<br /> D USER'S CHOICE CHWS - CHILLED WATER SUPPLY HYDR - HYDRAULIC RETURN (1500 PSI) SA - SPARGE AIR
<br /> CR04 - CHROMATE SAC - SULFURIC ACID
<br /> E VOLTAGE/ELECT. EAH EAL EC EE EI EIC ER ES ESH ESL ET CLWR - COOLING WATER RETURN SBS - SODIUM BISULFITE
<br /> F RATE FAH FAL FC FCV FE FY FI FIC FIT FQI FQIS FR FRC FS FSH FSL FT FV CLWS - COOLING WATER SUPPLY SCW - SCRUBBER WATER
<br /> G USER'S CHOICE
<br /> H HAND HIC HS HV SW - SOFT WATER
<br /> TEA - TRIETHANOLAMINE
<br /> I CURRENT/AMPS IAH IAL IC II IIC IR IRC IS ISH ISL IT
<br /> J POWER/WATTS ,�T UA - UNDERGROUND COMPRESSED AIR
<br /> LINE AND PIPING SYMBOLS IDENTIFICATION V - VENT
<br /> K TIME, TIME SCHEDULE KAH KAL KC KI KIC KR KS KSH KSL VAC - VACUUM
<br /> L LEVEL LAH LAL LC LCV LE LY LI LIC LR LRC LS LSH LSL LT LV
<br /> M MOISTURE (HUMIDITY) ME MI LI�KNOR II�NSTRUMENOCENPUMECHANICAL WW - WASTEWATER (COMBINATION STREAM)
<br /> N USER'S CHOICE
<br /> 0 USER'S CHOICE VENDOR PACKAGE LIMIT .
<br /> P PRESSURE, VACUUM PAH PAL PC PCV PY PI PIC PR PRC PS PSH PSL PT PV PNEUMATIC SIGNAL INSTRUMENT AIR
<br /> PD DIFFERENTIAL PRESSURE PDA PDAL PDC PDI PDIC PDR PDR PDS PDS PDS PDT L I N E N U M B E R D ES I G NATI 0 N �
<br /> Q QUANTITY CAPILLARY TUBING
<br /> R RADIATION
<br /> SOFTWARE INTERFACE
<br /> S SPEED, FREQUENCY SAH SAM SC SE SI SIC SR SRC SS SSH SSL ST _ - - - - - ELECTRICAL SIGNAL
<br /> T TEMPERATURE TAH TAL TC TCV TE TY TI TIC TIT TR TRC TS TSH TSL TT TV TW
<br /> U MULTIVARIABLE UR MAIN PROCESS PIPE SPEC
<br /> V VIB., MECH. ANALYSIS VAH VAL VC VE VI VIC VR VRC VS VSH VSL VT SECONDARY PROCESS LINE NUMBER
<br /> W WEIGHT, FORCE WAH WAL WC WE WI WIC WR WRC WS WSH WSL WT �--� �--� �
<br /> X ULTRAVIOLET XAH XAL XS XSH XSL �� �,� ELECTRICALLY HEAT TRACED LINE (INSULATED) OPTIONAL DESIGNATION
<br /> Y EVENT, STATE OR PRESENCE YAH YAL YC YI YIC YR YS YSIT YSL �� PIPE SERVICE .
<br /> Z POSITION, DIMENSION ZAH ZAL ZC ZE ZI ZIC ZR ZRC ZS ZSH ZSL ZT C_T WSULATED LINES (C=CLASS, T=THICKNESS, IN.) PIPE SIZE
<br /> UINSTRUMENT IDENTIFICATION EQUIPMENT SYMBOLS �'� STEAM TRACED LINES (C=CLASS, T=THICKNESS, �N.)
<br /> PP
<br /> LOCAL FIELD MOUNTED INSTRUMENT C PERSONNEL PROTECTION (C=CLASS, T=THICKNESS, IN.)
<br /> �JINCLUDING TRANSMITTER FOR I I I I PLATE HEAT EXCHANGER I N STR U M E NT SYM BO LS
<br /> SINGLE MEASURED VARIABLE XX � YY
<br /> � PANEL MOUNTED INSTRUMENT FOR o TRAP, SPECIFY TYPE PIPING SPECIFICATION CHANGE �— FLOWMETER, ANNUBAR .
<br /> SINGLE MEASURED VARIABLE BY NOTE OR SCHEDULE PIPE EXISTS BUT NOT SHOWN
<br /> —� --i�i--- FLOWMETER, ORIFICE
<br /> � PANEL MOUNTED INSTRUMENT DASHED LINE �-�, STRAINER, WYE .
<br /> � LOCATED ON FACE OF INDICATES BEHIND N0. CONTINUED ON SHEET N0. —��-- FLOWMETER, VENTURI
<br /> LOCAL CONTROL PANEL PANEL MOUNTINGS +� STRAINER, WYE
<br /> PANEL MOUNTED INSTRUMENT FOR WITH BLOWOFF � V V V V V V
<br /> � TWO MEASURED VARIABLES OR 0 STRAINER, BASKET FLUID DISPERSION PIPE FE INLINE FLOW ELEMENT
<br /> MORE THAN ONE FUNCTION OF CARTRIDGE FILTER TEMPERATURE ELEMENT
<br /> INSTRUMENT WITH TWO WITH THERMOWELL
<br /> � SERVICES OR FUNCTIONS QC CHEMICAL POT FEEDER VALVE SYMBOLS ,
<br /> (MULTIPOINT UNIT)
<br /> lO INTERLOCK LG LEVEL GAUGE
<br /> , Q EXISTING INSTRUMENT -�- STRAINER, DUPLEX �a GATE VALVE PRESSURE RELIEF/
<br /> PROGRAMMABLE LOGIC �E ELECTRIC ACTUATED � COOLING COIL � SAFETY VALVE -
<br /> -�--- CONTROL ACCESSIBLE D� GLOBE VALVE � MOTOR ACTUATED VALVE
<br /> TO OPERATOR � MOTOR ACTUATED H � HEATING COIL _
<br /> PROGRAMMABLE LOGIC �1 CHECK VALVE � SOLENOID OPERATED VALVE M I S C E LLAN EO U S SYM B 0 LS
<br /> � PUMP CENTRIFUGAL
<br /> �-- CONTROL INACCESSIBLE � PNEUMATIC ACTUATED � �
<br /> TO OPERATOR IC�I BALL VALVE CONTROL VALVE WITH �`�'" AIR VENT, MANUAL � SPRAY NOZZLE
<br /> COMPUTER FUNCTION � METERING PUMP � PNEUMATIC ACTUATOR (WITH DRAIN)
<br /> ACCESSIBLE MCC
<br /> MOTOR CONTROL CENTER i�5i PLUG VALVE/STOP COCK � REDUCER, CONCENTRIC
<br /> TO OPERATOR � PRESSURE REDUCING/ � FLEXIBLE CONNECTOR
<br /> PUMP (POSITIVE DISPLACEMENT, ROTOR) � REGULATING VALVE
<br /> � COMPUTER FUNCTION � � � NEEDLE VALVE REDUCER, ECCENTRIC
<br /> INACCESSIBLE �° (SELF CONTAINED) b �
<br /> TO OPERATOR oo EXHAUST FAN UNCLASSIFIED VALVE STRAIGHT INVERT
<br /> � I�I BUTTERFLY VA�VE PRESSURE REDUCING � (NUMBER & SPECIFY
<br /> RELAY FUNCTION (SEE BELOW) REGULATING VALVE / IN SCHEDULE) a REDUCER, ECCENTRIC
<br /> Y �, STRAIGHT CROWN
<br /> MIXER/AGITATOR WITH MOTOR � ANGLE VALVE (W/EXTERNAL TAP) P FLOOR DRAIN
<br /> RE REVERSE Ei ELECTRIC TO PNEUMATIC ] PIPE CAP
<br /> oR ACCEPT EITHER INPUT �/P ELECTRONIC TO PNEUMATIC THREE-WAY VALVE � FLOAT VALVE �
<br /> � LOWEST ❑ � I �I ORIFICE PLATE ISSUED FOF� PERMIT
<br /> � }�-f-f-K PUMP HOSE WITH CONNECTIONS -If- FLANGED FITTINGS i ,
<br /> [� HIGHEST � DIAPHRAGM VALVE � VALVE WITH
<br /> , HOSE CONNECTION , , � DIAPHRAGM SEAL �. . �
<br /> XXX --- ANALYZER FUNCTION (SEE BELOW) � M ELECTRIC MOTOR ,O, SPRAY BALL .
<br /> � COND. - CONDUCTIVITY N.O. NORMALLY OPEN �
<br /> H - ACIDITY BASICITY I�- BLIND FLANGE {V)�--� VENDOR INTERFACE '# %`
<br /> ORP - OXYGEN REDUCTION POTENTIAL VERTICAL PUMP OR '��.,,�r�� ,��, ����' �� �' �
<br /> SUBMERSIBLE PUMP N.C. NORMALLY CLOSED ,� , ,,;' �-� �� .,,,,,�
<br /> TURB - TURBIDITY ,��� � % �����.-n
<br /> CHR - CHROME F.O. FAIL OPEN — LIQUID LEVEL Q VENT
<br /> G R O U P
<br /> \ / M
<br /> INDICATING LIGHT �, AIR BLOWER F.C. FAIL CLOSED EQUIPMENT INSULATION 600 itewart St., St� 1400
<br /> � � Seattle, Washington 98101
<br /> SV SOLENOID VALVE EXHAUST DUCT
<br /> , BENERGY MANAGEMENT CONTROL SYSTEM PUMP (POSITIVE DISPLACEMENT� BFP BACK FLOW PREVENTER �''��;:'� T�I 206.�67.1700
<br /> FUNCTION (EMCS) � DIAPHRAGM) CV CONTROL VALVE j:��j
<br /> ��-�� �ax �06.267.1701
<br /> ���-�� -
<br /> ���:
<br /> SAZAN # 500-1775
<br /> SYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE ACCEPTABILITY ��WN DATE SUBTi7LE CURRENT REVISION SYMBOL DATE
<br /> �� L`���' THIS DESIGN AND/OR CHECKED PROCESS SYMBOLS DRAWING W2572915 - 07.�g.� �
<br /> - IRC ROUTER VAC PUMP H20 RECYCLE W2572915 SAZAN 07.18.17 ��� oF ��a°Ni t9;
<br /> ��� , �;o� SPECIFICATION IS APPROVED sHEEr
<br /> �.� r/ N IN TITLE
<br /> , � ��' �� � ��;fZ APPRovEo BY DEPT. DATE IRC - WBS 2.2.3.4.4 VACUUM PUMP WATER RECYCLE M 310��
<br /> ' ;, . ¢ l�r�'i` ���f �s �,., CHECKED
<br /> � 31�'' � �U I LD I N G 40-056 JOB N0. COMP No.
<br /> � ��,c�FcrsrEg��tir`�� APPROVED �
<br /> S'IONEIL E�
<br /> ��� � �
<br /> 07/17/2017 APPROVED MECHANICAL MASTER COL. X-X/X-X EVERETT °wc rvo. 40-056-�1310-4