<br /> EXISTING 5/8" GWB
<br /> TWO PIECE BONNET, 24 GA. VENT / PIPE SUPPORT CHEMLINK SEALANT EXISTING 10" METAL STUDS,
<br /> SEALANT JOINT GALV. STEEL MIN. SEALANT JOINT NOTE: PROVIDE 12" MIN. TYPE M-1 OR DURALINK HUNG FROM STRUCTURE
<br /> PREFABRICATED INSULATED CLEAR FROM ALL ABOVE, MODIFY FOR NEW
<br /> STAINLESS STEEL STAINLESS STEEL STAINLESS STEEL
<br /> CLAMPING BAND � ' z CURB W/ INTERIOR MTL. CLAMPING BAND OBSTRUCTIONS CLAMPING BAND OPENING HEIGHT
<br /> 5 8 GWB, PATCH AND
<br /> � � � LINER AND WOOD NAILER FLASHING MEMBRANE � PORTALS PLUS PVC BOOT - � �� -
<br /> , CLEAR OPENING 1 cn FLASHING MEMBRANE SET � SET IN BONDING � OR APPVD SUBSTITUTE x. �' PAINT TO MATCH EXISTING
<br /> REF. STRUCT. DWGS. �� �`' N IN BONDING ADHESIVE i ADHESIVE � � 0� WHITE-KNIGHT SINGLE
<br /> FASTEN AT TERMINATION BAR FASTENED HOT AIR WELD z COMPONENT URETHANE �� MTL. TRACK PER STRUCT.
<br /> 12 O.C. W/ SCREW AND MEMBRANE Z � AI,R BARRIER WRAPPED � I E , „ • SEE SHT. 7/S553 3
<br /> S E T I N A L L-P U R P O S E S E A L A N T � � 4 B A C K O N T O P O F N � E M B E D E D P O L Y E S T R 15 -6 �•
<br /> z FABRIC REINFORCEMENT MIN. '
<br /> � INSUL. AND SEALED
<br /> � SEAM SEALANT � I I A.F.F. •. •. � �
<br /> Q � � ROOF MEMBRANE � t `�; UD SECTION PER STRUCT. � .
<br /> . ... . _
<br /> .. : ..
<br /> ... , ...,. ... , ,.. .:. ; .
<br /> .,� . . . . .. . .,. .
<br /> � o � AIR BARRIER WRAPPED - � � ,_ .�,., � _ �, � � i � MTL. ST ; i i ;
<br /> . >> _
<br /> z � 4 4" BACK ON TOP OF ' , , , , , E , SEE SHT. 7/S553 3 . ; � � ;
<br /> �
<br /> .
<br /> NOTES � � \ I NSU L. AN D S EALED �, ;�X. ,�� ,� --- ---------- ---------------------- ------------------------------------ ------------- ------- ----------`� i ' � � i i
<br /> _ „ , ,
<br /> Y , X
<br /> � , � �,1�`n. ��� < � ' � � i
<br /> . , . !k I� � I�.- �'` 1�,� Z
<br /> _ � �� ------------------------------------- ' i I � ! �
<br /> 1 . VERIFY ROOF c� � ROOF MEMBRANE � � � � � � �----- REMOVE LOWER PORTION OF ! ! �
<br /> INSULATION THK. � �� I I � EXISTING WALL AS REQUIRED " .
<br /> ROOF INSULATION EXISTING NON-PVC SINGLE � FOR NEW OPENING HEIGHT �
<br /> W� REVIEWED SHOP � ;� .
<br /> DWGS. OF ROOF +� _� �� �� �������'`����� � _���� ���' � �� � ��� � � � � , (R=30 ROOF SYSTEM PLY ROOF MEMBRANE � � ,
<br /> ---------------------- --------------
<br /> ------------------------- , , � � ! ; ! ' .
<br /> INSUL. SUBMITTAL � I MTL. ROOF DECK � 'I -_ _ — _ �� � ; � ___ _ __ � ,
<br /> - � �
<br /> 2. C U R B S TO B E , AI R BA R R I E R B ETW E E N I, � ____ ____ ____ ____ _____ __� L_ -- - ` - ----- --^ J
<br /> FABRICATED W/ S � ROOF INSULATION DECK AND INSULATION INSTALLATION NOTES: o � �
<br /> SLOPING BOTTOM � (R=30 VENT STACK -REF. 1 . CLEAN SINGLE PLY MEMBRANE AN BOOT WITH MEK OR ACETONE TYPE SOLVENT. _
<br /> AND LEVEL TOP � � NOTE: PATCH JAMB EA. SIDE
<br /> I E MTL. ROOF DECK MECH. DWGS. FOR 2. APPLY BASE COAT OF WHITE-KNIGHT URETHANE COATING TO ROOF SURFACE � � „ � �
<br /> � � „ N w W/ 5/8 GWB AN D PAI NT z z
<br /> - EXHAUST STACK � SIZE EXTENDING PAST BOOT BASE A MINIMUM OF 4 . � > TO MATCH c~n ,_z,_,
<br /> REF: MECH. DWGS. AIR BARRIER BETWEEN 3. INSTALL BOOT INTO BASE AND APPLY ADDITIONAL WHITE-KNIGHT TO BASE OF BOOT.
<br /> DETAILS 8 M558 � DECK AND INSULATION 4. EMBED POLYESTER REINFORCING FABRIC INTO WHITE-KNIGHT COATING AT BOOT w o
<br /> AND 2/M588 STEEL PURLIN -REF: B A S E E X T E N D I N G T O R O O F S U R F A C E A M I N I M U M O F 3".
<br /> STRUCT. DWGS. 5. APPLY TOPCOAT OF WHITE-KNIGHT TO COMPLETELY EMBED REINFORCING FABRIC.
<br /> GEN. NOTE: STACK MFR. TO 6. INSTALL HOSE CLAMP AND APPLY SEALANT TO TOP OF BOOT. H EAD ER D ETAI � 4A H EAD ER D ETAI � 4B -
<br /> PROVIDE GUYWIRE SUPPORT SCALE: 3"-1 '-0" - A616 SCALE: 3"-1 '-0" - A616
<br /> AND ANCHORAGE. -
<br /> EXHAUST STACK PIPE PENETRATION RETROFIT PIPE PENETRATION
<br /> DETAI � � DETA � � F�ASHING BOOT DETAI �
<br /> SCALE: 1 1/2"=1 '-0" A616 SCALE; 1 1/2"=1 '-0" A616 SCALE: 1 1/2"=1 '-0" A616 CURB MOUNTED
<br /> � � � �EQUIP. REF:
<br /> ' MECH. DWGS.
<br /> CLEAR OPENING PREFABRICATED
<br /> BLOCKED OPENING I,NSULATED
<br /> PER STRUCTURAL , „ REF. STRUCT. DWGS. CURB W/
<br /> 1 -8 CORREGATED I�NTERIOR MTL.
<br /> TAL WALL 1/4" X 4"� STEEL CAP �LI N ER AN D
<br /> HEAD FLASHING �____ __ _ _ ME WOOD NAILER
<br /> ; + ------ - -------------+------------ - -------- +�
<br /> WELDED TO VER .
<br /> �- ; �______________________________________________ � H E A D F L AS H I N G , F L A S H I N G
<br /> SEALANT ; ; ; ; �- 4 DIA. STL. MEMBRANE
<br /> . � � � ; PIPE GUARDPOST FASTEN AT
<br /> � SET IN BONDING
<br /> ; i i i 14" DIA. PIPE � FILL WITH CONC. 12" O.C. ADHESIVE
<br /> , �
<br /> , _ ,
<br /> �
<br /> � o
<br /> �
<br /> �
<br /> � ; ; �
<br /> � TERMINATION
<br /> ;
<br /> � BAR FASTENED
<br /> � ; ; ,
<br /> °O ' � ' ' BLOCKED OPENING � �
<br /> , � � �
<br /> W/ SCREW
<br /> i
<br /> � � ,
<br /> �- i i � � BEYOND PER STRUCT. „ „ „ _ _ AND MEMBRAN
<br /> z ; ; ; ; 9 X9 X1/2 STL. SET IN ALL-
<br /> o ; ; ; ; PLATE W/ (4) 1/2 DIA.
<br /> STEEL ANGLE �'URPOSE SEALANT
<br /> � ; ; ; ; x 3 1/4 EMBED EXP. BOLTS SEAM SEALANT
<br /> FLASHING PLATE � ' ' � � FRAMING BEYOND
<br /> o ; � � �
<br /> � � �---------------------------------------------� �
<br /> , �� ' � 3/16 AIR BARRIER
<br /> ' � Q 4" WRAPPED
<br /> 14" DIA. DUCT = ; ; SILL FLASHING ,� 4 BACK
<br /> SEE MECH.
<br /> SI LL FLASH I N G � �-------------- - ----------------------------- - --------------, z °� o
<br /> +
<br /> ,
<br /> ~ ON TOP OF
<br /> � � _ � I�,NSUL. AND
<br /> PAINT SAFETY YELLOW � = o SEALED .
<br /> � ROOF MEMBRANE
<br /> PENETRATION DETAI � - SECTION PENETRATION DETAIL - E �E�ATION 6 DETAI �. g � ,
<br /> SCALE: 1 1/2"=1 '-0" - A616 SCALE: 1 1/2"=1 '-0" - A616 SCALE: 1 1/2" =1 '-0 1A10-42 A616
<br /> . �
<br /> NOTE: PROVIDE ALECO STRIP DOOR OR
<br /> EQUAL. STANDARD CLEAR PVC STRIPS, NOTES:
<br /> EXIST. HEADER 12" X 0.120" SMOOTH, OVERLAP 50�, �,
<br /> UNIVERSAL MOUNTING SYSTEM ALUMINUM 1 . VERIFY ROOF �
<br /> FOR SIDE-WALL OR LINTEL MOUNTING, SEALANT INSULATION THK. �
<br /> TOLL-FREE: 1-800-633-1320, , ROOF
<br /> - - - - ----- EMAIL: INFO�ALECO.COM, W/ REVIEWED I INSULATION
<br /> - - - WEB: WWW.ALECO.COM PRE-FINISHED DRIP OF�ROOF/GS (R-30)
<br /> FREEZER STRIP FLASHING CUT INTO
<br /> � BRACKET SIDING. 2. CURBS TO BE
<br /> CONTRACTOR VERIFY HT. 4" FABRICATED W/ I MTL. ROOF
<br /> � , SLOPING BOTTOMS DECK �
<br /> APPROX. 27 A.F.F.
<br /> AND LEVEL TOP I
<br /> STL. BEAM
<br /> C OR VERIFY HT ATTACH TO STL. BEAM W/ 7/16" 3. CURB THICKNESS � AIR BARRIER
<br /> CONTRA T EXIST. HEADER DIA. WELDED THREADED STUDS TO BE DETERMINED BETWEEN DECK
<br /> � FREEZER STRIP APPROX. 8' & 16' A.F.F. � 16" O.C. BY CURB MANUF. � AND INSULATION
<br /> FREEZER STRIP FOR LOAD SUPPORTED �
<br /> BRACKET PIPE PER �
<br /> ATTACH TO EA. STUD W/ 7/16" DIA. FREEZER STRIP MECHANICAL
<br /> D AND LOCATE 4 GEN. NOTE: STACK MFR. TO ' STEEL PURLIN -
<br /> CENTER BOLT ON STU REF: STRUCT.
<br /> � MIN. ABOVE BOTTOM OF STUD. FIELD VFY. PROVIDE GUYWIRE SUPPORT DWGS.
<br /> STUD LOCATIONS AND SPACING PRIOR TO EXISTING
<br /> METAL SIDING AIR INTAKE AND ANCHORAGE.
<br /> FABRICATION OF CONNECTION BRACKET D E TA I L�
<br /> 11
<br /> FREEZER STRIP @ FREEZER STRIP @
<br /> SCALE: 3"=1 '-0" A
<br /> HEADER DETAI � � ST�. BEAM DETAIL PENETRATION DETAI � 1 O ISSUED FOR PERMIT rolluda architects �
<br /> � SCALE: 3"=1 '-0" - A616 SCALE: 3"=1 '-0" - A616 SCALE: 1 1/2"=1 '-0" - A616 7 1R architecture planning interior design �
<br /> � ! ■ 1 V. � � 105 Souih Main Streei,Sulie 323,Seattle,WA 98104 206 024.4722 �
<br /> DRAWN DATE SUBTITLE CURRENT REVISION SYMBOL DATE �
<br /> SYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE ACCEPTABILITY MISCELLANEOUS DETAILS W2572915 � 07.18.�7 �
<br /> K IRC — WBS 2.2.3.1.4 INTEGRATED PAINT FACILITY W2572915 C/ROLLUD 06.01.17 E IRC — WBS 2.2.3.2.5 PARTITIONS 1 PP 2SF 5MB W2572915 RAI 09.23.15 sso4 THIS DESIGN AND/oR CHECKED
<br /> ( � � � GISTERED SPECIFICATION IS APPROVED SHEET ;
<br /> L IRC — WBS 2.2.3.4.4 VACUUM PUMP WATER RECYCLE W2572915 C/ROLLUD 07.18.17 F IRC—WBS2.2.3.1.5 CURING OVENS—HAND LAYUP W2572915 RAI 02.03.16 �,�� � ' A HITECT cNE KE� TITLE IRC — WBS 2.2.3.4.4 VACUUM PUMP WATER RECYCLE A616 �
<br /> BO APPROVED BY DEPT. DATE
<br /> G IRC—WBS2.2.3.1.5CURING OVENS—HAND LAYUP—DCN2 W2572915 RAI 03.1 Q.16 RIC C T H C�
<br /> APPROVED B U I L D I N G 40—V� JOB N0. COMP N0. c
<br /> C IRC — WBS 2.2.3.2.21—VACUUM FORMS (4MC)—DCN W2572915 RAI 09.23.15 H IRC—WBS 2.2.3.2.9 LININGS (1 SF, 1 LB) W2572915 EC/ROLLUDA 06.29.16 STATE OF WASHINGTON W2572915 _
<br /> D IRC — WBS 2.2.3.2.31 PARTITIONS 3MB W2572915 RAI 08.26.15 J ADDITIVE MANUFACTURING (3D PRINT SHOP) W2572915 C/ROLLUD 10.26.16 APPROVED ARCHITECTURAL MASTER EVERETT, NIA °wc No. 40-056-A616
<br /> ( )
<br />
|