Laserfiche WebLink
w <br /> POI/Pla4e f ° d9e) <br /> ALLIED 3 Alrr <br /> CONSTRUCTION ASSOCIATES,tNC. <br /> REQUEST FOR INFORMATION NUMBER: 16 <br /> PROJECT: Kennedy Court Remodel <br /> SUBJECT/ ITEM: rebar reinforcem= f. ADA ramp <br /> SPEC/ DWG. REF: A3.1 <br /> REQUEST: <br /> A3.1 &the repair specification document, section 2.7 handicap access ramp, show detailed sections of the <br /> concrete ADA ramp for unit 3228 C and call out for rebar reinforcement through out. What is the size,frequency, <br /> and configuration of the rebar reinforcement of this concrete structure? <br /> COST IMPACT: unknown SCHEDULE IMPACT: unknown DATE/TIME: 2/13/17 8:30am <br /> NEED ANSWER BY: 2/16/2017 FIRM: ACA BY: Will Swanson <br /> RESPONSE: <br /> For the vertical curbs for the ramp rebar shall be#3 rods at 2'-0" o.c. vertically and one#3 bar within <br /> 12" of the top and bottom of the curb, keeping clear of areas where coring or sleeving for the <br /> guardrail shall be located. <br /> Run#3 dowels at 24" o.c. from the vertical curbs into the slab portion of the ramp for a length of 12". <br /> The slabs shall have 6x6 WWF in the mid 1/3 of the slab and tied to the dowels. <br /> DATE ANSWERED: 02/15/17 FIRM: Housing Hope BY: Todd Bullock <br /> 3120 Hewitt Avenue Everett, WA 98201 Phone(425)259-6057 Fax(425)259-7120 <br /> License#ALLIECA008DF <br />