View plain text
BLOWER DOOR TEST RESULTS <br /> 1 BDT <br /> Blower Door Testing NW Date of Test: ,S' ) j 7 / 1 e <br /> 425-31 -3914 •BlowerDoorNW.com Technician Name: a )14411(4� <br /> blower(l'oorschedule@gmail.com <br /> i <br /> Job Si e Information <br /> Permit #: <br /> Addr ss and Lot Number: #q qX) 0 C-eafriIci <br /> City: ej V-ttr�,; VV r> Zip Code: q.CC:;4).-5 <br /> Con 3.Floor Area(ft2): 3 GIL I te Age of House: Ale <br /> rce (check one): Plans ❑Estimated ❑_ Isured <br /> fest Results <br /> Pass. 1'1 ❑Fail ❑ Could Not Complete _ 3 l Volume <br /> 2 ` (e( ACH50 <br /> Test Target 5—0 C ttL q CFM@50Pa <br /> Ring(check one if applicable): Open A ❑B ❑ C <br /> Blower Door Fan Location: illiL.JAM I i Weather Conditions: <br /> Results shall be reported as Air Changes per Hour at 50 Pascals (ACH50)and shall be calculated as follows: <br /> ACH50=(CFM50 x 60)/Volume <br /> Where: <br /> CFM50=Blower door fan flow at 50 Pascal pressure difference <br /> _1 <br /> Volume=Conditioned Floor Area of the housing unit x ceiling height <br /> 2015 Washington State Energy Code reference: <br /> R402.4.1.2 Testing.The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 5 air changes per hour.Testing shall be conducted with a blower <br /> door at a pressure of 0.2 inches w.g.(50 Pascals).Where required by the code official,testing shall be conducted by an approved third party.A written report of the results of the test shall <br /> be signed by the party conducting the test and provided to the code official.Testing shall be performed at any time after creation of all penetrations of the building thermal envelope.Once <br /> visual inspection has confirmed sealing(see Table R402.4.1.1),operable windows and doors manufactured by small business shall be permitted to be sealed off at the frame prior to the test. <br /> During testing: <br /> 1.Exterior windows and doors,fireplace and stove doors shall be closed,but not sealed,beyond the intended weatherstripping or other infiltration control measures; <br /> 2.Dampers including exhaust,intake,makeup air,backdraft and flue dampers shall be closed,but not sealed beyond intended infiltration control measures; <br /> 3.Interior doors,if installed at the time of the test,shall be open,access hatches to conditioned crawl spaces and conditioned attics shall be open; <br /> 4.Exterior openings for continuous ventilation systems and heat recovery ventilators shall be closed and sealed; ' <br /> 5.Heating and cooling systems,if installed at the time of the test,shall be turned off;and ' <br /> 6.Supply and return registers,if installed at the time of the test,shall be fully open. <br />
The URL can be used to link to this page
Your browser does not support the video tag.