My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2019 RAINIER AVE 2018-12-21
>
Address Records
>
RAINIER AVE
>
2019
>
2019 RAINIER AVE 2018-12-21
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/21/2018 1:34:30 PM
Creation date
12/21/2018 1:34:26 PM
Metadata
Fields
Template:
Address Document
Street Name
RAINIER AVE
Street Number
2019
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
42
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
I/V i ,Lbofv V/ 4I7G4-00N .^ <br /> IC11507.3.4 Whole-house ventilation using exhaust fans. <br /> M1507.3.2 Control and operation. This section establishes minimum prescriptive requirements <br /> I. Location of controls.Controls for all ventilation for whole-house ventilation systems using exhaust fans.A <br /> systems shall be readily accessible by the occupant. system which meets all the requirements of this section shall <br /> 2. Instructions.Operating instructions for whole house be deemed to satisfy the requirements for a whole-house <br /> ventilation systems shall be provided to the occupant ventilation system. <br /> by the installer of the system. M1507.3.4.1 Whole-house ventilation fans.Exhaust <br /> 3, Local exhaust systems.Local exhaust systems shall fans providing whole-house ventilation shall have a flow <br /> be controlled by manual switches,dehumidistats <br /> rating at 0.25 inches water gauge as specified in Table <br /> timers,or other approved means <br /> 4. Continuous whole-house ventilation systems. M1507.3.3(1).Manufacturers'fan flow ratings shall be <br /> 'Continuous whole-house ventilation systems shall determined according to HVI 916 or AMCA 210. <br /> M1507.3.42 Fan noise.Whole-house fans located 4 feet <br /> operate continuously and be equipped with an <br /> override control.A"fan on"switch shall be permitted or less from the interior grille shall have a sone rating of <br /> as an override control.Controls shall be capable of 1.0 or less measured at 0.1 inches water gauge. <br /> Manufacturer's noise ratings shall be determined as per <br /> operating the ventilation system without energizingHVI <br /> other energy-consuming appliances.A clearly visible 915(March 2009).Remotely mounted fans shall be <br /> acoustically isolated from the structural elements of the <br /> label shall be affixed to the controls that reads <br /> "Whole House Ventilation(see operating building and from attached duct work using insulated <br /> instructions)." flexible duct or other approved material. <br /> M1507.3.4.3 Fan controls.The whole-house ventilation <br /> 5. Intermittent whole house ventilation systems. <br /> fan shall meet the requirements of Section M1507.3.2 and <br /> Intermittent whole-house ventilation systems shall <br /> comply with the following: M1507.3.2.1. <br /> 5.1. They shall be capable of operating M1507.3.4.4 Ventilation openings.Each habitable space <br /> intermittently and continuously. shall be provided with outdoor air inlets or operable <br /> 5.2. They shall have controls capable of operating windows with an openable area not less than 4 square <br /> the exhaust fans,forced-air system fans,or inches of net free area of opening for each 10 cfm of <br /> supply fans without energizing other energy- outdoor air required by Table M1507.3.3(1).Where <br /> consuming appliances.5.3 outdoor air supplies are separated from exhaust points by <br /> 5.3. The system shall be designed so that it can doors,provisions shall be made to ensure air flow by <br /> operate automatically based on the type of - installation of distribution ducts,undercutting doors, <br /> control timer installed. installation of grilles,transoms,or similar means.Doors <br /> 5.4. The intermittent mechanical ventilation system shall be undercut to a minimum of 1/2 inch above the , <br /> shall operate at least one hour out of every surface of the finish floor covering. <br /> four. • <br /> 5.5. The system shall have a manual control and Individual room outdoor air inlets shall: <br /> automatic control,such as a 24-hour clock 1. Have controllable and secure openings; <br /> timer. 2. Be sleeved or otherwise designed so as not to <br /> compromise the thermal properties of the wall or <br /> 5.6. . window in which they are placed; <br /> 5.7. At the time of final inspection,the automatic 3. Any inlet or combination of inlets which provide <br /> control shall be set to operate the whole-house 10 cfm at 10 Pascals are deemed equivalent to 4 <br /> fan according to the schedule used to calculate square inches net free area. <br /> the whole-house fan sizing. Ventilation opening shall be screened or otherwise <br /> 5.8. A label shall be affixed to the control that reads protected from entry by leaves or other material. <br /> "Whole House Ventilation(see operating Openings shall be controllable,securable and shall be <br /> instructions)." designed to not compromise the thermal properties of the <br /> M1507.3.2.1 Operating instructions.Installers shall building envelope.Ventilation openings shall be located <br /> provide the manufacturer's installation,operating so as not to take air from the following areas: <br /> instructions,and e whole house ventilation system 1. Closer than 10 feet from an appliance vent outlet, <br /> operation description unless such vent outlet is 3 feet above the outdoor air <br /> M1507.3.3 Mechanical ventilation rate.The whole- inlet. <br /> house mechanical ventilation system shall provide 2. .Where will prkup objectionable odors,fumes or <br /> outdoor air to each dwelling unit at a continuous rate of flammablu vapors. <br /> not less than that determined in accordance with.Table 3. A hazardous or unsanitary location. <br /> M1507.3.3(1), 4. A room or space having any fuel-burning appliances <br /> therein. <br /> Exception:The whole-house mechanical ventilation 5. Closer than 10 feet from a vent opening of a <br /> system is permitted to operate intermittently where the plumbing drainage system unless the vent opening is <br /> system has controls that enable operation for not less at least 3 feet above the air inlet. <br /> than 25 percent of each 4-hour segment and the 6. Attic,crawl spaces,or garages. <br /> ventilation rate prescribed in Table M1507.3.3(1)is 7. Asphalt roofs unless it is shown that no other location <br /> multiplied by the factor determined in accordance with is permissible.In such cases the inlet opening shall <br /> Table M1507.3.3(2). be located a minimum of 2 feet from the nearest <br /> surface of the asphalt roofing,measured from the - <br /> intake opening. (#• 12 <br />
The URL can be used to link to this page
Your browser does not support the video tag.