r GENERAL NOTES <br /> FOR WINDOWS IMTH OPERABLE OPENINGS MORE THAN 72' <br /> ABOVE THE FINISHED GRADE OR SURFACE BELOW, THE IP; <br /> LOWEST PART OF THE CLEAR OPENING SHALL BE 24" a IA <br /> IA <br /> MINIMUM ABOVE THE FLOOR. EXCEPTIONS: FULLY OPEN <br /> WINDOWS WHERE A 4" SPHERE MAY NOT PASS THROUGH <br /> OR WHERE FALL PREVENTION DEVICES ARE PROVIDED PER <br /> ASTM F 2090 OR R312/2. + <br /> PROVIDE SAFETY GLASS PER IRC R308. <br /> SKYLIGHTS TO BE DOUBLE PANEL, SHATTER RESISTANT <br /> APPROVED RIGID PLASTIC, LAMINATED SAFETY GLASS, 0 <br /> 26'-0' FULLY TEMPERED GLASS, HEAT-STRENGTHENED GLASS, It'ir <br /> / <br /> 6' OR WIRED GLASS. PROVIDE 4' MINIMUM CURB (OR SELF <br /> FLASHING ASSEMBLY WITH 3:12 MINIMUM PITCH OR PER <br /> MANUFACTURER INSTRUCTIONS). ' <br /> :-- HOSE BIBBS TO BE BACKFLOW PREVENTION AND FREEZE ` <br /> h .' RESISTANT TYPE. <br /> I <br /> All HOEDOWNS. FRAMING ANCHORS & SHEARWALL „ <br /> NAILING MUST BE INSPECTED BEFORE COVERING, i 4 i <br /> aLANDINGS & STAIRS AT EXT. DOORS R311.3ill <br /> THERE SHAW.BEA LANDING OR FLOOR ON EACH SIDE <br /> EACH EXTERIOR DOOR. THE WIDTH OF THE LANDING SHALL <br /> NOT BE LESS THAN THE DOOR SERVED. EVERY LANDING <br /> SHALL HAVE A MINIMUM DIMENSION OF 36' IN THE <br /> DIRECTION OF TRAVEL THE SLOPE SHALL NOT EXCEED 2%. <br /> LANDINGS AT REQUIRED EGRESS DOORS SHALL NOT BE <br /> MORE THAN 1)f LOWER THAN THE TOP OF THE THRESHOLD. <br /> W EXCEPTION: THE LANDING ON THE EXTERIOR SIDE SHALL BE <br /> 7NOT MORE THAN 7j' BELOW THE TOP OF THE THRESHOLD <br /> in PROVIDED THE DOOR DOES NOT SWIG OVER THE LANDING. <br /> "� GARAGE b WHEN EXTERIOR LANDINGS SERVING THE REQUIRED EGRESS <br /> 4' CONC SLAB N DOOR ARE NOT AT GRADE, THEY SHALL BE PROVIDED WITH $ <br /> TAS A RAMP (R311.8) OR STAIRWAY(R311.7) TO GRADE. <br /> SLOPE i :1L ' TO DOORS OTHER THAN THE REQUIRED EGRESS DOOR SHALL <br /> DOOR(S BE PROVIDED MTH LANDINGS NOT MORE THAN 7' BELOW <br /> THE TOP OF THE THRESHOLD. EXCEPTION: A TOP LANDING <br /> IS NOT REQUIRED WHERE A STAIRWAY OF NOT MORE THAN <br /> TWO RISERS IS LOCATED ON THE EXTERIOR SIDE PROMOED <br /> DEPRESS STEM 0 THE DOOR DOES NOT SWING OVER THE STAIRWAY. <br /> DOOR OPENING STORM AND SCREEN DOORS SHALL BE PERMITTED TO SWING <br /> -*„.. OVER EXTERIOR STAIRS AND LANDINGS. <br /> CONTINUOUS FOOTING '`° <br /> CONTINUOUS FOOTING 0 GARAGE DOOR0 In <br /> DEPRESS STEM 0 0 GARAGE DOOR OPENING <br /> DOOR OPENING f OPENING FOOTING SCHEDULE <br /> ...)_,______11.i( <br /> 46 DF#2 COL 4x6 DFie COL FII - • MARK HxWxD REINF. BAR <br /> E 0 0 12 6x12x12 <br /> 1<j2 15 7x15x15 <br /> N 18 8x18x18 <br /> 20 9x20x20 ill <br /> 2'-1QX" / 16'-3" / 6'-104. 24 10x24x24 (3)#4 EA. WY. ig <br /> 30 12x30x30 (3)14 EA. WY. <br /> i 26'-� / 32 12x32x32 (4)#4 EA. WY. <br /> 36 12x36x36 (4)14 EA. WY. " <br /> 15C 8x15 CONT. (2)#4 CONT1N. <br /> ALL EXTERIOR FOOTINGS TO EXTEND <br /> 18" BLW FIN. GRADE MIN. UNLESS <br /> NOTED OTHERWISE. STRIP ALL WOOD <br /> .. FOUNDATION PLAN SCALE: r = 1'-0" FORMS PRIOR TO BACKFILLING. 2 <br />