h ' 'L 0 _ <br /> FOR WNDOWS WITH OPERABLE OPENINGS MORE THAN 72' <br /> ABOVE THE FINISHED GRADE OR SURFACE BELOW, THE <br /> LOWEST PART OF THE CLEAR OPENNG SHALL BE 24' <br /> MINIMUM ABOVE NE FLOOR. EXCEPTIONS: FULLY OWN 4 N4 <br /> WINDOWS WHERE A 4" SPHERE MAY NOT PASS THROUGH <br /> OR WHERE FALL PREVENTION DEVICES ARE PROVIDED PER <br /> ASTM F 2090 OR R312.2.2 <br /> PROVIDE SAFETY GLASS PER HRC R308. <br /> h <br /> SKYLIGHTS TO BE DOUBLE PANEL, SHATTER RESISTANT <br /> APPROVED RIGID PLASTIC, LAMINATED SAFETY GLASS, <br /> 26'-O' FULLY TEMPERED GLASS, HEAT-STRENGTHENED GLASS, 16188 <br /> ' OR WIRED GLASS. PROVIDE 4' MINIMUM CURB (OR SELF <br /> 6 <br /> ,,6' FLASHING ASSEMBLY WITH 3:12 MINIMUM PITCH OR PER <br /> MANUFACTURER INSTRUCTIONS). "Efill <br /> • 144k----I—- 1 RESISTANTS BACKFLOW PREVENTION AND FREEZE <br /> • <br /> ALL HOLDOWVS. FRAMING ANCHORS &SHEARWALL <br /> NAILING MUST BE INSPECTED BEFORE COVERING. 4f <br /> LANDINGS & STAIRS AT EXT. DOORS R311.3 d <br /> OJ <br /> THERE SHALL BEA LANDING OR FLOOR ON EACH SIDE OF <br /> EACH EXTERIOR DOOR. NE WIDTH OF NE LANDING SHALL <br /> NOT BE LESS THAN THE DOOR SERVED. EVERY LANDING <br /> SHALL HAVE A MINIMUM D1ME NEON OF 36" IN THE <br /> DIRECTION OF TRAVEL THE SLOPE SHALL NOT EXCEED 2X. <br /> LANDINGS AT REQUIRED EGRESS DOORS SHALL NOT BE <br /> MORE THAN 11r LOWER THAN NE TOP OF TIS THRESHOLD. <br /> W EXCEPTION: THE LANDING ON THE EXTERIOR SIDE SHALL BE <br /> 7NOT MORE THAN 7j" BELOW THE TOP OF THE THRESHOLD <br /> 7/1 PROVIDED DE DOOR DOES NOT SWING OVER THE LANDING. <br /> .0 <br /> GARAGE WHERE EXTERIOR LANDINGS SERVING NE REQUIRED EGRESS <br /> 4' CONC SLAB I DOOR ARE NOT AT GRADE, THEY SHALL BE PROVIDED WITH 16 <br /> FILL & TAMP A RAMP (R311.8) OR STAIRWAY(R311.7) TO GRADE. <br /> SLOPE:'- ' TO DOORS OTHER THAN THE REQUIRED EGRESS DOOR SHALL <br /> BE PROVIDED WI1H LANDINGS NOT MORE THAN 7Y4" BELOW <br /> THE TOP OF DE THRESHOLD. EXCEPTION: A TOP LANDING <br /> IS NOT REQUIRED WHERE A STAIRWAY OF NOT MORE THAN <br /> TWO RISERS IS LOCATED ON THE EXTERIOR SIDE PROVED <br /> DEPRESS STEM 0 THE DOOR DOES NOT SWING OVER THE STAIRWAY. <br /> DOOR OPENING-N._ STORM AND SCREEN DOORS SHALL BE PERMITTED TO SWING <br /> ..._____} OVER EXTERIOR STAIRS AND LANDINGS. <br /> CONTINUOUS FOOTING (1) <br /> �'o <br /> CONTINUOUS FOOTING 0 GARAGE DOOR DEPRESS STEM -0 GARAGE DOOR OPENING <br /> DOOR OPENING OPENING <br /> • <br /> `� -'- �'- - - - - FOOTING SCHEDULE i.' <br /> I .�_ DFP COL IF- <br /> 4x6 I>F2 ca��_ — — — I .-� MARK HxWxD REINF. BAR ', <br /> * 12 6x12x12 <br /> NE m o 15 7x15x15 a <br /> /1 <br /> N a N 18 8x18x18 ig <br /> 20 9x20x20 ' <br /> 2'-10.k" 16'-3" 6'-10)x' 24 10x24x24 (3)14 EA. WY. .. 1g <br /> 30 12x30x30 (3)14 EA. WY. ° <br /> 26'-0' 32 12x32x32 (4)#4 EA. WY. <br /> 36 12x36x36 (4)14 EA. WY. :� <br /> 15C 8x15 CONT. (2)#4 CONTIN. <br /> . ALL EXTERIOR FOOTINGS TO EXTEND <br /> 18" BLW FIN. GRADE MIN. UNLESS <br /> NOTED OTHERWISE. STRIP ALL WOOD <br /> FOUNDATION PLAN SCALE X = 1' FORMS PRIOR TO BACKFIWNG. 12 A. <br /> }/ 4 f 1 <br /> 9 <br />