Laserfiche WebLink
SlDING - SEE ELEVATIONS T ' <br /> 5 <br /> � FOR TYPE /j,J�,j 1„ D1 <br /> , <br /> �� �---W.R.B. (TYP.) UNIT <br /> �4' T&G PLYWOOD SUBFLOOR UNIT �i�i��i.ii� <br /> �I SEE DETAILS 8/11 AND UNIT � 2 2 <br /> � I`t 17/I1 FOR INSTALLATION OVER 2X FLOOR FRAMING 1Ye" FLOOR SHEATHING <br /> � � C�? 16" O.C. U.N.O. <br /> „ � <br /> ; I � <br /> . <br /> NEADER PER � 2 6 � � � 2 X 12 STRlNGERS <br /> i/i/�,/��i/i/�y, <br /> STRUCTURAL � � I = `� 2 2 2 AT 12" O.C. ,�;��,,���� �;, , � <br /> � � � SLOPE � , <br /> � <br /> , ; 10' MIN. 1X8 GARAGE T io �o � <br /> . <br /> � � � 1Y$" FLOOR SHFATHING r <br /> 1x8. . .. .. ..... ... .. .. . . . .: � � ! � � � � � � ' <br /> � ; 2x12 STRINGERS <br /> i �i � PROVIDE R-30 INSUL. �} <br /> GWB ; � 2 AT 12" O.C. �: � � � � �: �` C; 1 ��: <br /> �'����% %� OVER UNHEATED <br /> ; 24 GAUGE PPM FLASHING i;ir y,�i;;i;ir;;i; �� f � <br /> . SPACES PROV DE R 30 I SUL. <br /> � � � OVER' UNHEATED� <br /> : ' <br /> PROVIDE SEALANT END DAMS � . .... . ...:._.:... .,. .. . .... . : . ...... : .. .. ,..,. -. .: . . . . ....: : ... - :.. ...,,,...;. . : :. ., ... .�. SEE UNIT STAiR z <br /> � SPACES. 25;��trfrrii Way; �ut��2�� , <br /> , AT EACH END PLANS FOR RISER <br /> ( � AND TREAD s a. (1) LAYER f�tr�€�p�tt(,:W��tTi��}t�n �80�� <br /> � � %a EXTERIOR TR(M (TYP.) DIMENSIONS. 2 6 5ls" TYPE X GWB - ' �, , , t <br /> f_� ----- i SEE ELEV. FOR WIDTH (1) LAYER 5/a" GWB (1) LAYER ���'������ � ���������� <br /> . <br /> � (5/» TYPE 'X' GWB WlTH UNlT z �s" GWB ���r��rt+�fit���br���d�S��'����,�t <br /> � R-21 1NSUL. � � � � ,.,.<. _... �. . :�..�.. ..���. ..,:�� <br /> SEALANT SEALANT AND BACKER ROD R-30 INSOVERf�GARAGE} <br /> PROVIDE 2x8 BLOCKING PER MFR INSTALLATI�N <br /> (FOR DRAPERY) EACH 51DE REQUIREMENTS SEE UNfT STAIR 5052 REGISTERED � <br /> OF HEAD AT ALL BEDROOM PLANS FQR RISER � ARCHITECT <br /> AND GREAT ROOM WINDOWS VINYL SLIDING GLASS DOOR AND TREAD <br /> (TYP.) DIMENSIONS. � . <br /> PAT14 DOOR HEAD INTERMEDIATE STA1R LANDING STAIR DETAIL AT GARAGE TOP 4F STAIR DETAIL ROBERT E. WEIBLE <br /> 1�-7 � � STATE OF WASHINGTON <br /> ! 9 <br /> 3�� _ ,�-o�� SECTION , ,�2�j = ��-o�� SECTION 1 1/2�° = ��-o�° SECTION 1 1/2�j = �°-o°� SECTION <br /> 1" T T -a <br /> � � <br /> , � > <br /> . � 5 i %! �; <br /> PROVIDE BLOCK(NG FOR ! D1 i iii�fiiiii �i! i iii /�iii iii i��i °' <br /> TRfM AND SIDING FlN. FL. i 2 s :. 1Ya" FLOOR '^ <br /> � i 1Ya" FLOOR SHEATHING T � . �� a, ' <br /> GWB �� � , 1Ya FLOOR � � SHEATHING .L <br /> 2 SHEATHING i <br /> � �, 2x12 STRINGERS �» 1�� � <br /> 2 2 - SEALANT ; ! AT 12" O.G, i��i��ii�ii�i�i � . <br /> EXTERIOR ; '� ��������?��''��� 2 X 12 STRINGERS 2x12 STRINGERS � i%iii ii�'i��i/� � ' <br /> � � f 1x8 PROV(DE R-30 <br /> � ', AT 12" O.C. AT 12° O.C. ' � <br /> ' ' PRQVlDE R-30 WSUL. 9 INSUL. OVER - <br /> SLOPE � 10 OVER UNHEATED D5 UNHEATED �X8' 20A 5 1x8 � <br /> � 10° MIN. ; i 2 s � "� SPACES. SPACES. D1 D1 PROVIDE R-30 INSI � <br /> � 6 6 � ; I� � s : „ � , (1) LAYER �a" GWB BO T MrPLATE 2x BLOCKWG OVER UNHEATED i a <br /> , <br /> ' S/a TYPE X GWB 2 z � SPACES. .� <br /> � : G RAGE .. a , a a Q : d -� <br /> . <br /> � � � � � � <br /> ' -----------=----=---�___===_=____ _�---- � d � °- Q..a 4 ° a . d c <br /> -----------,�__-= v a a , • n . a. . r�� LAYE � <br /> ( R <br /> - HEAD ~� '. LI Q Q d 4 , Q. . d Q 7'Saz GWB � <br /> __________ I � �, � ' ' . � . . . •. . . ' � . , o . I <br /> SIDING, SEE ELEV. FLASHING (1) LAYER r, � <br /> : � <br /> � <br /> FOR TYPE SHIM, PER DOOR '' I� 5/s" TYPE X GWB ` ° BEAM PER STRUCTURAL ' o <br /> �� N <br /> SEALANT PER SIDING MFRS REQUIREMENTS %2" GWB (MIN.) AT GARAGE �o io — � I l T — T o .� <br /> _ ; � � <br /> MFRRE s IRE EN�S SHI AS NEEDED ��y ^' . . .. I I I=) I I=j I I=I I '=I I i—� I �I��—E ( (i I I �I I I—I i—I I I '=I I I—I I I I I —t o o �� . <br /> I — � — — — -- --- , <br /> RER DO MENTSR )NSTALLATION 2x10 TRIM , , � i—i � �—� � ;—� I 1=1 I 1= � I 1—I I I ��I ( I—I I I; .I I �— _ . ... � . ...... . .... . r.. � o <br /> Q ER ROD M I I I I I I I I I I I I I I I I ,I I I _ I I I I I I I I I I <br /> II_ _iI1-1I � � � � _ , , ' i � o <br /> F L A S H I N G S Y S T E M Q� R S E E U N I T S T A I R S E E U N I T S T A I R S E E U N I T S T A I R � <br /> SEE DETAILS 8/11 5/4X5Yz EXTERIOR TRIM (TYP.) H E A D E R P E R P L A N S F O R R I S E R P L A N S F O R R I S E R P L A N S F O R R I S E R <br /> AND 17/11 SEE ELEV. FOR WIDTH � S T R U G T. <br /> --- AND TREAD AND TREAD AND TREAD <br /> 2x HEAD TRIM '� -° DfMENSIONS. DIMENSIONS. DIMENSIONS. <br /> -a <br /> SLIDINC PATIC� DOOR �AMB TYP. �ARAGE HEADER BCJTTOM OF STAIR � LANDING BOTTOM �F STAIR c� CONC. BOTTOM OF STAIR � N <br /> 1 8 1 4 1 0 6 2 � , <br /> 3" = 1'-0" P�N 1-1�2 = 1 -0 S E C T I O N 1 1/2 = 1 -0 s E�.T��N � �/2 = � -o S E C T I O N 1 1�2 = 1 -0 S E C T I O N � r <br /> :> , „ „ , „ » , „ ,. , „ o <br /> ct 1„ T <br /> �NTER�°R `� ' EXTER�°R INSULATION AND ENEIZGY NOTES � <br /> S!QlNG - SEE ELEVATIONS RIPPED 2x8 FRAMWG � i ir �i;/ ii i�� � ' <br /> 1 � � l G,,i/,i�,, . . . . . . . � o <br /> ' �"� �I FOR TYPE 16" o.c. FOR LANDING lYs" FLOOR � L- o N <br /> . 2 6 � ;; W.R.B. (TYP.) SEE STAIR PLANS FOR SHEATNING �� - G��d ��$ � O o <br /> �� SEE DETAILS 8/11 AND LANDING HEIGHT � 2x12 STRINGERS 1x8 All insulation matenals shal) be installed according to the manufacturer`s RII exterior doors or doors serving as access to an enclosed unheated ,� Q <br /> � ; FOUNDATION OPENING „ » instructions to achieve ro er densities and maintain unifarm R-values. area shall be weafiherstri ed to limit leaka e around their erimeter when in a <br /> SEE STRUCTURAL ' � 17/11 FOR INSTALLATION %z GWB (MIN.) AT 12 O.C. p � � pp g p � 0 <br /> � � ; DOOR SIZE o Substantial contact of the insulation with the surface being insulated is required. closed position. �,,, <br /> FOR HEADER SIZE SHEATHING OVERHEAD DOOR PROVIDE �'������i��fr��i�r��i%��% �fi��y��r��i%����i�%%� Where required, insulation shall be installed with clearances according to The thermal transfer characteristics of insulated doors shall be U-value 0.30 � � <br /> ; I �/�" MIN. GAP SYSTEM BLOCKING FOR ° manufacturer's specifications. (nsulation shall be installed so that required or better per WSEC section R402.1.1. � L- • <br /> TRIM AND SIDING '� <br /> ' ; I , o � ventilation is unobstrueted. For blown or poured IoQse fiill insulation clearances Q � o; <br /> � \ ` shall be maintained through installation of a permanent retainer. '�"'' 3 <br /> � �-24 GAUGE PPM FLASNING � � 2„ ., 2x BLOCKfNG � (1) LAYER VV�1'K�4W� � a - <br /> c <br /> i � ° �e" GWB Glazing U-values for windows and SGD shall be U-value 0.30 or better per : • <br /> , , <br /> � F�ASHING sYSTEM � a1 �� WSEC section fZ402.1.1 as indicated on the unit plans. . <br /> , ; s s s HANGER PER R-10 slab on grade insulation shall be installed inside the foundation wall and Windows shall be furnished with outdoor air inlets as indicated on the Unit <br /> ; 2X TRIM _____ _ STRUCTURAL � <br /> � ' SEALANT PER MFR � shall extend down vertically 24 or to the top of the footing whichever is less Electrical plans. Inlets shall have a controllable and seeure opening and be <br /> � �� � � INSTALLATION y+' SIDING SEE ELEV. ° BEAM PER STRUCTURAL per WSEC section R402.2.9. capable of a total opening area of not less than four (4) square inches and <br /> REQUIREMENTS FOR TYPE, INSTALL PER � tested by a nationally recognized standard or approved agency and located � � <br /> DOOR FRAME %4 X 5Y EXTERIOR TRIM (TYP.) MFR REQUlREMENTS �� to avoid drafts. Inlets shall be screened or otherwise protected from entry by o •� <br /> _. <br /> S/4X5Y EXTERIOR TRIM (TYP.) SEE ELEV. FOR WIDTH FLASHING SYSTEM ° �6C� A00�$ insects, leaves, or other material. "' j <br /> SEE ELEV. FOR WIDTH 2x B�O C K I N G Floor insulation shall be installed in a ermanent manner in substantial <br /> .. .. .. . ..._. .. . <br /> IN-SWINGING � AS NEGESSARY SEE UNlT STAIR contact with the surface bein insulated. I�nsulation su orts shall be installed so <br /> DOOR SEALANT PER DOOR MFR SEALANT PER MFR PLANS FOR RISER g pp � <br /> INSTALLATION 5 AND TREAD spacing is no more than twenty-four inches on eenter. R04f/�%6�1� <br /> lNSTALLATION REQUfREMENTS PER PLANS <br /> EXTERIOR REQUIREMENTS �� DIMENSIONS. Fioors separating conditioned space from unconditioned space shal( have a Roof/Ceiling insulation: Open-Biown or poured loose fili insulation may be <br /> vapar barrier installed. Vapor barner shall be installed on the warm side of the used in attic spaces where #he slope of the ceiling is more than 4 in 12 and '�"� � <br /> EXTE R I O R DOO R H EAD �nsulation. The vapor barrier shall have a one perm dry cup rating or less (i.e. there is at least 44 inches of clear distance from the top of the bottam chord <br /> �(� �� GARAGE QOO R JAMB B4TTQM LAN D I N G e� STAI R four mil, ol eth lene or kraft faced materiaU The floor sheathin ma be used of the truss or ceilin � <br /> ✓ p y y g y g joist to the underside of the sheathing. When eave vents <br /> 3" = 1'-0" S�CT�ON 1-1/2" = 1'-0" PLAN ,-,�2" = 1'-0" �ECT�ON as the vapor barrier if rated (and so stamped) at one perm (maxJ Otherwise are installed, baffling of the vent openings shall be provided so as to deflect � <br /> place vapor barrier on top of joists befare placing sheathing. the incoming air above the surface of the insulation. Baffles shall be rigid � � <br /> material, resistant to wind driven moisture. When feasible, the baffles shall be O � <br /> ; ; , installed from the top of the outside of the exterior wall, extending inward, to a � tt� <br /> PRovIDE B�oGKING FOR EXt9�itN WC�B point six inches verfically above the height of noncompressed insulation, and Q� � <br /> TRIM A�ID SIDING � 2x8 FRAMING All wall insulation shall fill the entire cavity. Exterior wall cavities isolated tweive inches vertically abave loose fill insulation. Baffles shall be in place at � � <br /> 1NTERIOR � EXTERIOR TRlM AT @ 16" o.c. during framing shall be fully insulated to the levels of the surrounding walls. All the time of framing inspection. Q� <br /> I GARAGE DOOR JAMB faeed insulation shall be face stapled to avoid compression. Where the ventilation space above the insulation is less than an average of Q 0 � <br /> ' Walis separating conditioned space from unconditioned space shail have a twelve inches roof ceiling assembhes shall be provided with a vapor barrier � � V <br /> :. . . . . . . .. ., . � HANGER PER �� �1-+ <br /> ^T SECTIONAL OVERHEAD � o vapor barrier installed. Faced batt insulation shall be face stapled. Vapor having a 0.5 perm cup rating or less. Faced batt insulation where used as a � � C _ <br /> STRUCTURAL barrier shall be installed on the warm side of the insulation. va or barrier shall be face sta led, � ;C � <br /> 2 2 I c � DOOR TRACK AT SIDES 2x BLOCKING `�, ° pVa or barriers shall not bepe uired in rooflceilin assemblies where the � N <br /> ; ;; ; OF OPENING P q 9 O � � <br /> ----- , � , ventilation space above the insulation averages twelve inches or greater. � � <br /> --�-- <br /> EXTERIOR � ' � L�� Vapor barriers shall be installed on the warm side of the insulation. J S � � <br /> � � N These air leakage notes apply to those locations separating outdoor = ; � <br /> FLASHING SYSTEM � � I ambient conditions from interior spaces that are heated or mechanically cooled. V � L � <br /> 6 6 SEE DETAlLS 8/11 � i SEE DETAIL 11/D2 Exterior joints around windaws and door frames, betwe�n wall cavities and Fi6�8 Gi Z <br /> FOR GARAGE SLAB 5 � W O � <br /> ' AN� 17/I1 � � AND APRON � ' window or door frames, openings between walls and foundation, �etween walls Fireplaces shall be provided with each of the foliowing: <br /> _________________ �� ' � and root and wall anels o enin s at enetrations of utilit services throu h a) Ti htl fittin flue dam ers o erated b a readil accessible manual or ~ W � <br /> ----- <br />