Laserfiche WebLink
15-4" <br /> 15'-4" 12'-8" 2'-8" <br /> 12'-2" _ 3'-2" � <br /> - <br /> 4'-03 " ,_ �, 2,_5� » >_ �, ._ ,r i 5,_�1 �, 5'-13 �, , , I , ; <br /> �4 5 8 �4 1 8 1 6 �4 �4 1 -3 � <br /> , 18 � I � � , <br /> � (D4 � ' <br /> _ ` �---a- ;. ,, <br /> -------- '------ <br /> _�� <br /> --- '------ <br /> 15'-4" � � �-I .� <br /> 12'-8" � �� , � � � �; <br /> � j 2 -8' \ o D1 ��Ck 11 � � ( I � � ; <br /> 5'-11�2" 6'-8�2" j I , � D I I � I a, � <br /> , <br /> , 2 1 � " `n `� 3 I ' I p D1 2 � � � � � � � .� � ;� � ' <br /> I, , ' <br /> I N S U LATI O N ( D3 D1 6-Q�5-0 SL �� � 5-0 4�-0 SL �-�� �_ � � � 1 I �', � � ,� � �- �r �3 � � ; - <br /> ......... ........ .... .............. �..... . .... .... 1 0 � � . � <br /> . .......: _ , , ; <br /> FOUNDATION PERIMETER - R-1 Q RIGlD ; EGRESS ` p3 i � ,. SAFETY GLAZING -� � �� Q s i � ( � 25 Gen���l 4�(t��; �u�t�2�0 < <br /> _ �' yVH �, , <br /> INStJLATION TO A DEPTN OF 24" OR TO TOP ; : : 6 � : N � Kk�-kCt�nd,�c��h�n�t�� ��4�3 <br /> OF FOOTING AT HEATED PERIMETER �1 -----------------=N --- ......... ......yf l 2Q � ,....,.. .......�f o � <br /> � \ �� D4 � � � I P 4�5���37��0 � 4�5 65� €208 <br /> WALLS: 2x6 WALLS WITH FIBERGLASS BATTS 1 � j� �1 �5 ;��'�� � = � ' ��;q �,+��r��(brp�tti#�t€rcka.��m ° <br /> OR BLANKETS — R21 ' �n � 1 �� ; -; 1 � f � <br /> '� � �' I� UL APPROVED � � 1' j' � ZX4 FUR WALL i <br /> FLOORS OVER UNHEATED SPACES — R-30 ' N � � i� I�-� ( 4- AT WH LOCATION <br /> �� t ¢ � � ,� ELECTRIC FfREPLACE ,� �. (I <br /> ATTICS AT TRUSSES — R-49 � � _ �- � (� °' '� I� I NOTE: PER IRC R302.6 MIN. I 6 8 5052 � <br /> � 1 ^ m I � � I TILE NEARTH (OPTIONA(�) %$ TYPE X GWB SHALL BE D2 D1 - REGISTERED <br /> (R-38 SHALL BE DEEMED TO SATISFY THE - � <br /> �v ,� Bedroorn o � �, cv 1 (, �r, I � ARCHITECT <br /> � REQUiREMENT OF R-49 WHEREVER TNE FULL r- � � i � m 1 0 1 CJ STEP � � APPLlED TO CEIL(NG OF GARAG� � �q. i <br /> HEIGHT OF UNCOMPRESSED INSULATION EXTENDS 1 I � i ,) Living � � WHERE HABITABLE ROOMS ARE D2 � � <br /> OVER THE WALL TOP PLATE AT THE EAVES) '� 3'-2" �Y2� 3�-���� i' � � 1' �8 , ABOVE. MIN.Y" GWB APPLIED TO ; <br /> 1 i � D3 � I ALL WALLS, BEAMS, AND POSTS � � �TEP RoBERT E. WEIBLE <br /> EXTERIOR DOORS: DOORS BETWEEN HEATED �� 8-2 '� �j �' `i WITHIN GARAGE. STATE OF WASHINGTON , <br /> � i 14 � q�_p�� , <br /> ORDBET ERATED SPAC�S SNALL BE U=Q.30 �' � � S�I�F �� '� �2» � 9�2�� 3'-10" � D3 <br /> � <br /> WINDOWS: ALL WINDOWS AND SGD TO NAVE 1 � ;-----; j � ,1 SOFFIT � � p I <br /> U-FACTOR OF U,0.30 OR BETTER � I 24„ TB � ,�, • ' �' '�' � (, r � �p� TYP. ' <br /> i � .� <br /> \ 18 I � I � <br /> D3 � _ _� D1 1 � 4 SlM. ----- C, �j � <br /> INSULATE UNDER STAIRS ANQ IN WALL ( N � <br /> CAVITIES ABOVE BOTTOM QF STRfNGERS ; �)I � w p �` � -, 3-0 7-0 18 ,, - -.--:.-.--;--.-- -.---o .- - I ' ' p <br /> � f', �--- � 1�a�h �2 "x30"I BIFOLD� ; D3 �1 --- -- --- --- �. ._ ; � <br /> i' �1 I o � � TTIC � � �' ( .. . ._..� . 3-Q BIFOLD (� , , � . <br /> LOGATE PLUMBING � I ' � v' P ; G , jA CESSj 1 14 8 � ;� •�. <br /> CON-fINUE COMMQN WALL <br /> ' ROUGH-IN ACCOUNTING I �'�3 0 ; � _J D5 N �� D3 D1 I GWB THROUGH FUHRING o 1 (� � INSULATE UNDER � `� <br /> GYPSUM WALLBOARD SCHEDULE FOR SHEAR PANELING � �' �� � °' O TYPICAL � � � . <br /> � _� ,� �, D5 � STAIR 0 �, <br /> 5/a" GYPSUM WALLBOARD (GWB) SHALL BE AND (2) L,AYERS GWB 0� �+- DN � <br /> : . � : � • <br /> USED TNROUGHOUT ON INTERIOR WALLS, AT COMMON WALL I!'� „ „ LOW WAL� � , Ij LOW WALL j� � � i �----------- �- � <br /> INTERIOR SII�E OF EXTERIOR WALLS AND � '' SNOW R � �G �� AT +42 A.F.F. �, o � +42 A.�.F. �� '� o � � � �------------ i �v o � <br /> CEI�INGS EXCEPT AT EXTERtOR WALLS AND _� ; �� N W WOOD GAP � � ' ' � _� � � � � �°- <br /> o� � `i. � � � � a� `B �� Din�ng a� 1 rn -� r------------ � �n z v� a, <br /> COMMON WALLS REQUIRED TO NAVE A 1-NR � ��� ;.� � � � � O i �� � "� ; '� � p w � <br /> OR 2-HR FIRE-RESISTANCE RATING IN ^ '1� � � C� STEP � �NSULATE FLOQR OVER "' �I � i __--_____ , Z � <br /> WHICN CASE 5/s'� TYPE 'X' GWB SHALL BE `� � 5-��3 1 18 '� UNHEATED SPACE ( \ �- ---�- > ¢ "� <br /> USED. � �4 -4 HC � 3'-10" � D3 � _ f� � I , ----- I � v � <br /> °° 8 14 �� 24" TB M. ga t h : �, �2 � 8 14 `) 19 � �I � , \ --4,-�,-,--- W W � <br /> Q1 D3 � � D5 ; D1 D3 2,_2» D1 SIM. N 1 � �i _--------- � � � <br /> 18 �� , �n ' RAlSED FLOOR O -- --------------- ---- (' `v .. ........ ...... r O O �`' <br /> , D3 � rP � �c �� . ....... �, ... � m <br /> � ' � , � � � ... ........ ....... !. .:.... FUR WALL OUT : . .... � � � <br /> .... <br /> , � ----- ---- - ---- - ---- , <br /> � � ' o ' I ___ ^ � � FOR ELECTRICAL. • --- ----- �� o `�° °-' �, <br /> � <br /> . 1 I � (I \ 1 r `� o _ . <br /> .� <br /> � 2 � I r� i! I � �j 1'-1" 1, i � o `r � <br /> LOW WALL . I _ ,� <br /> �1 D1 i' � i il j +36" ABV. NOSING N jI `� II N � o � <br /> ,, � ; ,� � ,� � aa = <br /> � _ , <br /> � � <br /> � �� �, � i, �� � � �P �� Cara e uP � 2 � <br /> `�' 1 i � co 2—$ � � D2 � <br /> i 10 <br /> :N �f -- m � 1� � \ 'j j �' D5 �I -� SELF- LOSING � SCW � � � <br /> � � '� � � T <br /> � �� Master Bedroorr� � ; � � � I� � Kitchen = � 7 RA-�° ' � � <br /> Q 'i � �' �� CQ� � p2 Entry � � N . <br /> d- � � \ �� a O <br /> � II I ' tl L ° c� ( - 8 6 � g `�� 1� � � <br /> ' I j � CHASE FOR `j � � P wrr.� � D1 D2 ' � D2 ��s'�, j <br /> � <br /> �1 1 , FAN VENT �� � 2x8 �� � 14 15 � � ,i� <br /> . I � BELOW �1 2 � 18" TB ( D5 , _ <br /> � i � ,i � 01 TP 1' Q STEP 8-Q 7-0 SOHD I I �i <br /> _� � � � '<v c0 <br /> 1... .......; ............... ......... ..� ;� t... ........ .t �6 I r- <br /> : : , � pW � :... .. ... .. � 11 � <br /> .. ..... . <br /> I ; Y ^ ; ; 1 i O ; -0 3-0 F 2 � o o � D2 D5 i I i � � � N <br /> Q � D3 � E G R E S S ; � D 3 D 1 a �, p� 3 � �---_., : D3 I � D3 D1 I i i FLOOR ABOV i N � � Q <br /> . <br /> :..... .....: N N D 2 <br /> :..... ..... Q <br /> . � . . . . .. L___,_-L_______ -J I . � <br /> � 6-O I 5-0 S L , 6-0 4- DBL SL � � I ( � a.. <br /> � D1 , r--- -- ----i------- -- --- � � ,. <br /> 4,_3" 4'_3„ 2'_3" 2,_5" � 4'-3" 4'-3" 2'-2" 1'-8" 4'-0" 4'-0„ 1,_8•= 2'_2'> ,n/ <br /> ' 2'-2" 8'-6" 4'-8" 2'-2" 8'-6" 4'-8" � 11'-4" 4'-0" ' <br /> � ,V • <br /> i V <br /> �, 15'-4" � � 15'-4" I� � o � Q <br /> UPPER LEVEL MAIN LEVEL LOWER LEVEL � � Q . <br /> � N � E FLOQR PLAN � I� � E FLOOR PLAN � I� I.T E F L O O R P L A N <br /> ��4;�_�� �„ ���„_1'-0° _ ��4„_1'-0° - <br /> 0 <br /> � <br /> � � <br /> a �� <br /> tn _ <br /> � <br /> y T <br /> � , <br /> � <br /> � <br /> N O T E S � � <br /> FRAMING: 2x6's AT EXTERIOR WALLS THE FIREPLACE SHALL BE LISTED BY UL OR FM AND � � <br /> 2x4's AT lNTERIOR WALLS SHALL BE lNSTALLED IN ACCORDANCE WITH THAT O (jj <br /> UfVLESs NOTED OTHERWISE. USTING � � <br /> SEE S1.1 FOR STUD SCNEDULE, PROVIDE WATER RESISTANT GYPSUM WALLBOARD > � <br /> •••••••••••�•••••• R-21 BATT INSULATION BENIND TUB AND SHOWER ENCLOSURE MATERtALS � C Q <br /> ------ 3%2" ACOUST. 1NSUL. EACH SIDE TO A HEIGHT OF 7�" M(NIMUM ABOVE THE 0 � � <br /> , OF PARTY WALL, UNO. DRAIN INLET. � � <br /> � �' �' � <br /> CONCEALED SPACES SHALL BE FIRESTOPPED IN B�TH NO PLUMBWG, MECNANICAL EQUIPMENT, DUCTS OR � � � � � <br /> DlRECTfONS AT 10'-0" ON CENTER AND AT FLOORS. VENTS SNALL BE LOCATED IN THE COMMON UNIT <br /> TYPICAL. SEPARATION WALLS PER 1RC SEC. R302.2 (EXCEPTION) �� Q t� 3 <br /> � � ..� <br /> ALL ESCAPE OR RESCUE WINDOWS FROM SLEEPING ALL BEDROOM AND BATNROOM DOORS SNALL BE � � � �•+ <br /> ROOMS SNALL HAVE A MINIMUM NET CLEAR OPENING UNDERCtJT A MWlMUM OF %4" ABOVE THE ADJACENT <br /> OF 5.7 SQUARE FEET. TNE MINIMUM CLEAR OPENfNG FLOOR COVERING. � � � � � <br /> HEIGNT DIMENSION SHALL BE 24 . THE MINIMUM CLEAR o Q� Z <br /> OPENING WIDTN DIMENSION SHALL B� 20". SILL THE FRONT DOOR SNALL BE OPENABLE FROM TNE w > <br /> NEIGNT SHALL BE NOT MORE THAN 44" ABOVE THE INSlDE WITNOIlT �HE USE OF A KEY OR ANY SPECIAL. � W � <br /> FLOOR PER IRC SEC. R310.1.1. KNOWLEDGE OR EFFORT. IT MAY BE PROVIDED WlTH A ,� O <br /> NIGHT LATCH, DEAQ BOLT OR SECURfTY CHAIN, •'� � <br /> WHERE SILL AT OPERABLE WINDOW IS L�CATED MORE PROVIDED SUCH DEV(CES ARE OPENABLE FROM TME � � <br /> � THAN 72 INCHES ABOVE FINISHED GRADE OR OTNER INSIDE WITHOUT THE USE OF A KEY OR TOOL, AND — <br /> SURFACE BELOW, S)LL NEIGHT SHALL BE MINIMUM 24 MOUNTED NOT TO EXCEED 48" ABOVE THE FWISHED � O . <br /> WCNES A80VE FINISNED FLOOR. PER IRC SEC. 392.2.1. FLOOR. Q O, <br /> � <br /> ALL GLAZfNG SHALL CONFORM TO IRC SEC. R308.4, STAIR NOTES: � <br /> HAZARDOUS LOCATIONS. GLAZING IN A�L DOORS SHACL LOCATE HANDRAILS AT 34'-38" ABOVE THE <br /> BE SAFETY GLAZEQ. ALL GLAZENG WITH(N A 24" ARC STAIR NOSING. � <br /> OF EITHER VERTICAL DOOR EDGE SHALL BE SAFETY <br /> GLAZED. ALL. GLAZING WITHIN 60" OF A NAZARDOUS HANDRAIL GRASP DIMENSION SHALL BE BETWEEN 1" & <br /> LOCATtON, OR "WET SURFACE" SNALL BE SAFETY 1-1/4". PROVIDE CONTINUOUS NARiDRAlL OR � Job No.: 13-47 <br /> GLAZED. TERMINATE � � <br /> AT NEWE� POSTS OR SAFETY TERMINAL. SEE U�� FOR II�TERIC�R ELEVAT�I��IS � Sheet No.: <br /> PROVIDE 5/a" (MIN.) GYPSUM SNEATHING ON j <br /> WALLS BEHIND TUB/SHOWERS TO SATISFY FIRE WHERE USED AS A GUARDRAIL, A MAX. OPENING OF AND �NTER��R STA1R PLANS , U � <br /> " REQUIREMENTS AT UNIT SEPARATION WALLS CONDITION. 4�• <br /> � <br /> Sheet Order: A � � F � � J D � � _ <br /> ' T <br />