Y
<br /> U
<br /> N
<br /> N �
<br /> E °' � ,i �P �
<br /> built up end wall framing ° �
<br /> C 7
<br /> .� �
<br /> �� � t claddin er elevations � �
<br /> plumbing flashing panel - , Yp 9 p
<br /> � �
<br /> � ` � � snip hole in back'g to � � and 1 M
<br /> � appropriate size �� � � 4e.
<br /> � 9 wide SAM @ �ambs � ������� �� ��
<br /> ; „ �` lapped o/flash'g collar, ; � ; �� � - T
<br /> 9 wide SAM adhere to jamb & � ` � under head wrap � � , 6 strip flash g & WRB o/vert. � �
<br /> flash le ����� �� ��������
<br /> r� � head flanges - lap o/ paper below I � , � � 9 9 �
<br /> { ` �.. ' � 24 GA head flash' � ' � �
<br /> � g - , � flash'g - set o/trim in cont. bed of T � 1333 N Northlake Way Suite A
<br /> exist g hose bibb - � snip & bend as shown � � � sealant �, Seattle, Washington 98103
<br /> seal @ base to pipe , � , ,
<br /> �
<br /> � � f set piece 2 in sealant to piece 1 ; ,� 3" bent end dam's ; � � 4„ T ■ phone 206 547 7288
<br /> � � � � � � i as re 'd � Metal railin s s stem bracket
<br /> � I n slope - , � i 3/8"high end dam -slo e g y
<br /> � ,� I bldg. paper above lapped � � � 1/2 as req'd i � i beyond-fold down � P � Ref. structure for requirements fax 206 547 0833
<br /> =� o/ SAM & paper below \ _ -mount to inside of guardwall
<br /> , �I , �
<br /> I --1 1"w/3/8"hem �
<br /> bldg. paper below under flange � � \ ,- � siding not shown for clarity - ; u typ guardwall per
<br /> , � ' set m sealant to block & � 1/8" EPDM gasket -
<br /> � � provide fillet seal � hold back & seal all around � �� ��
<br /> � i � � �� � `�'� ���� �;�'���
<br /> I�� � �
<br /> PIECE 2 / � rail s stem ' � �-
<br /> � I \ �' re-finished flash' � y ;� I,% o � �'-,�'`aN����,�p
<br /> � �� � � polllar g � (2) 1/4" s.s. screws set into ��'� ��� m `� � ������ �� � �������
<br /> � �I I : N �`�'��`� �� �#��������"�°�°��
<br /> � sealant - min. 1 1/2" embed into ��� �I� ���� � � �
<br /> _ � � ,
<br /> � a ,� �, hemmed edge � 5/4x fixture blook - size as � (e) fram g � � � � � ; �� � �� _
<br /> � o �, for interlock � req d to allow 1 1/2 all around � WRB to top of vert. leg of � � ���� � � 3/8 neoprene gasket �
<br /> ; � � with PIECE 1 & set in sealant o/flash'g collar � flash'g � ' '
<br /> I ; i i
<br /> � I � �
<br /> � I � ; � � mounting bracket w/ SS �
<br /> �� � 2° flange al� around � � 9" wide flexible flash'g ; set siding in sealant to underside � I I � , ; fasteners per structural
<br /> NOTES: � , of trim & provide fillet seal � I I � �
<br /> - construct flash g of 24 GA galv. steel - under flash g collar � ' ;
<br /> cont. sfllder all joints P�ECE � 1„ j � � N ; j = _ � � �____ ' cont. cement panel cladding �
<br /> i n s t a l i p i e c e 1 f i r s t - s e t p i e c e 2 w/ h e m s � � ote. Return all to p rail ends to � �
<br /> � walls - verif confi uration
<br /> interlocked o/ piece 1 in bed of sealant , � Y g ; I I �
<br /> - prime all surfaces - field paint to match 4" � � ���� I I � Q
<br /> y , solid blocking and attachment �
<br /> verif per structural a
<br /> W
<br /> Z �
<br /> HOSE BIBB FLASHING LIGHT FIXTURE BLOCK RAIL TO WALL RAIL CONNECTION 1 Q
<br /> SCALE: 3" = 1'-0" � SCALE: 3" = 1'-0" � SCALE: 6" = 1'-0" � � �� _ �_ �� 1 � �
<br /> SCALE. 3 - 1 0 � �
<br /> � ^
<br /> � � O
<br /> 0 A cont. pre-finished flash'g per � � W
<br /> detail w/mitered corner /� 9" SAM adhered to head &
<br /> j � � jamb flanges of PVC box w Z
<br /> , , � �
<br /> � Oq Og set cont. flash'g in two beads �,�+ '� 24 GA re- rimed head flash'
<br /> I sealant over backer boot � ,,-'� '� � - extend 3/8" be ond box & g � �
<br /> typ cladding per elevations and � � �,.' '� y � � � �
<br /> ,�, ; r�-� provide bent end dams
<br /> , 4• � � � O interlock hemmed edge of /, �-. w J
<br /> �� existing exhaust duct into neck of new vent 0������ � � cont. flash'g w/backer boot r-.-' �-=,-'� , � 4„ as req'd - slope � � ^ W
<br /> � � i ` �� �r�- ��-��__ I � �
<br /> �� � lap WRB o/ head flange �� �� -� - �
<br /> i �� i� � � ' \ �
<br /> �� �� ��� �� 26 GA alv. backer boot / r . - . � „ „
<br /> i� ; � � � � g �� .�,' ,Jl�, �� � 1/2 w/ 1-3/8 hem � �
<br /> � �' '� 6" wide SAM o/top and side � �°� � � � . '- ��� '` �, ;� � (�er�fy) (�
<br /> flange of vent �� p/ soldered seam - g atch � ��� � ,,, � . � �
<br /> ' ��� �� �� rofile of cont. flash' � �; ,,,%-' � � �,� �
<br /> 6�� -' ,;�,- � � ,,, �� pre-finished flash g collar Q �
<br /> „ ; 24 GA galv. vent housing w/ end dams - � ' � - - -f z z �
<br /> (e) concrete wall - paint " prime & paint � � / � te$m nlat onent end dam � ,�' ' ` � ,.,",,:- i . , . —
<br /> R&R exist g fixture � W
<br /> u end dams O �� � '! ���•� ���:'�'.a � Q �
<br /> 1/8" x 2" continuous neoprene � `E �� . 1 ,-� ,;:� k" � J W
<br /> gasket �45� SPLICE JOINT ;' `• ' ' -%'' ; ' ' Z � W
<br /> � - - � � trim box —
<br /> Y � �
<br /> 22 ga pre-finished galvanized 4"flange all sides �; �.'F Y . i ' i �R
<br /> '' I i t V �
<br /> steel flashin with outsi�e � � � � �, � � � , � � �, ,-'���� ������� � m
<br /> g �� � �
<br /> ��� hemmed edge and down 24 GA re- rimed vent hood - aint � �� � � � �' ' ' � � ' � �
<br /> ,�� turned back stop p p p I � I � Q � �� � �� � ; --�, � I W •�
<br /> , �
<br /> 9 flexible flash g under M W
<br /> ' i 2" �' � � y +� i i . �� �
<br /> I '�2`' o� 4�� N � � � �� � �� � � r � flange of exi st'g PV C tr i m b o x I■Y
<br /> � ��j ' � �� �
<br /> � � - la o/ bdl a er below W �
<br /> izo � $ � �~��� � ��� � �� � � � �!� ;� i�''� p 9 p p
<br /> � i : � � �� � � � i V � / i�
<br /> � I � � � � �� � � � ��� �, � � Z
<br /> � provide down turned ends $�� � �� � �� a r
<br /> � � � . � '� 0 -� � �� � W
<br /> . ' ��' � o
<br /> � secure w/ bolt in expansion �� dampered outlet sized to fit exist'g duct - � > � � � r ,,
<br /> � shield 24" OC ��, � set in sealant to housing C ,�� ��,, � �
<br /> /I,' NOTE: lap new bldg paper o/ head � �
<br /> � existing infills remain - �� �; set siding in sealant to vent lip 3" minimum �3" minimum � flashing & head & jamb wrap �
<br /> I p �
<br /> protect ;� � 6" wide SAM under base flange of vent - 0 � � � � �
<br /> , over WRB below OUTSIDE CORNER INSIDE CORNER W
<br /> GARA E a� ~
<br /> G SCREEN AND HOOD VENT OUTLET L HOOD TYP FLASHING SPLICES �
<br /> SCALE: 3" = 1'-0" v SCALE: 3" = 1'-0" � SCALE: 3" = 1'-0" 6 F I XT U R E F LAS H I N G
<br /> SCALE: 3" = 1'-0"
<br /> 5 W
<br /> Bid set 2/29/16
<br /> Permit 3/9/16
<br /> 4 .
<br /> RAIL & TYP FLASHING
<br /> DETAILS
<br />
|