� 3s�-s�� 4�-0�� MIN. STANDARD SANITARY SEWER NOTES: GENERAL NOTES: � <br /> MIN. <br /> � 1. ALL WORK AND MATERIALS SHALL CONFORM TO THE CITY OF EVERETf 1 . BEFORE COMMENCING CONSTRUCTION OF UTILITY SERVICES, VERIFY <br /> w - - <br /> � W ITTINGS AS STANDARDS AND WSDOT/APWA STANDARD SPECIFICATIONS. LOCATION OF SERVICES PENETRATING THE BUILDING WALL WITH <br /> � REQ�D : PLUMBING. IF A CONFLICT EXISTS, NOTIFY THE OWNER IMMEDIATELY. <br /> Q Q - , „ 2. NO PART OF THE SANITARY SEWER SYSTEM SHALL BE COVERED, <br /> cn o 4 -0 MIN. C O N C E A L E D O R P U T I N T O U S E U N T I L I T H A S B E E N T E S T E D, I N S P E C T E D, 2. N A T U R A L G A S R O U T I N G I S S C H E M A T I C F O R U T I L I T Y C O O R D I N A T I O N <br /> � N 6„ ``�. 6» AND APPROVED BY THE CITY INSPECTOR. PURPOSES. COORDINATE WITH PUGET SOUND ENERGY ON GAS SERVICE <br /> PRIVATE BUILQING <br /> ROUTING. <br /> �' � 1 ' - `� 3. APPROXIMATE LOCATIONS OF EXISTING UTILITIES HAVE BEEN 4BTAINED <br /> , ,y; � - --"- SERVICE PRESSURE FROM AVAILABLE RECORDS AND ARE SHOWN FOR CONVENIENCE. THE 3. RESTRAIN ALL PIPES, JOINTS, AND FITfINGS OF THE WATER SYSTEM. <br /> A _ A SEWER CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFICATION OF LOCATIONS MEGALUG RESTRAINTS SHALL BE USED AT ALL MECHANICAL AND . <br /> � � � AND TO AVOID DAMAGE TO ANY ADDITIONAL UTILITIES NOT SHOWN. IF RESTRAINED JOINTS. o <br /> o CONFLICTS WITH EXISTING UTILITIES ARISE DURING CONSTRUCTION, THE <br /> -� CONTRACTOR SHALL NOTIFY THE PUBLIC WORKS INSPECTOR AND ANY 4. RESTRAIN ALL PiPES, JOINTS, AND FITfINGS OF THE SANITARY SEWER � - <br /> �` SURFACE RESTORATION VARIES, CHANGES REQUIRED SHALL BE APPROVED BY THE CITY ENGINEER PRIOR FORCE MAIN. � <br /> 45'x2" BEND BLIND FLANGE SEE PLANS TO COMMENCEMENT OF RELATED CONSTRUCTION ON THE PROJECT. � <br /> PLAN 2'� PLUG VALVE, FLG. DEZURIK SERIES 100 4. ALL SEWER MAIN EXTENSIONS WITHIN THE PUBLIC RIGHT-OF-WAY OR IN <br /> ECCENTRIC PLUG VALVE OR EQUAL. <br /> „ EASEMENTS MUST BE STAKED BY SURVEY FOR LINE AND GRADE PRIOR MATERIAL SPECIFICATIONS (SANITARY SEWER�: N <br /> 2 CHECK VALVE, FLG. RED VALVE OR EQUAL. <br /> FINISHED �������%� TO STARTING CONSTRUCT(ON. <br /> z <br /> , GRADE SPRING ASSISTED, GALV. DIAMOND � ``�� TRENCH BACKFILL 1. ACCEPTABLE PIPE MATERIALS (GRAVITY SEWER): � <br /> PLATE COVER WITH LOCKING LATCH � -PVC PIPE CONFORMING TO ASTM D3034 SDR35. � . . <br /> � ���� -DUCTILE IRON PIPE CONFORMING TO ANSI A 21.51 OR AWWA � <br /> •�� ~�.,` . . ,� ��'' STANDARD WATER NOTES: C151 . DUCTfLE IRON PIPE SHALL BE CLASS 52. � <br /> , PLUG �%� ���� TRACER TAPE -REINFORCED CONCRETE SEWER PIPE CONFORMING TO ASTM C76. � _ <br /> 2 MIN. COVER :� CHECK VALVE i�� 9" PIPE 9" 1. NO CONNECTION TO THE EXISTWG MAINS WILL BE ALLOWED EXCEPT BY 2. ACCEPTABLE PIPE MATERIALS (SEWER FORCE MAIN): N <br /> �:' VALVE �� TONING WIRE MEANS OF AN APPROVED BACKFLOW PREVENTION DEVICE PRiOR TO -HDPE PIPE CONFORMING TO AWWA C906, DR 9. a <br /> O.D. SATISFACTORY FLUSHING, TESTING, DISINFECTION, AND RECEIPT OF -PVC PIPE AND FITTINGS CONFORMING TO ASTM D2241, SDR 21 OR <br /> FLOW ' � <br /> ��, ;� BEDDING SATISFACTORY BACTERIOLOGICAL TEST RESULTS. AWWA C900, CLASS 150 WITH PUSH ON JOINTS. <br /> . z <br /> :', � � �� ��,,� GRAVEL � � :�:�::-_�:�: :. :::: , -DUCTtLE IRON Pf PE (SEE NOTE 1 ABOVE). a m <br /> 6" MIN ����� ���:�:�_� � 4' :�:..:�. ��i� FOUNDATION 2. CONNECTIONS TO AND TAPS ON EXISTING MAINS WiLL BE MADE BY THE <br /> ..� �%� ' �� � :�:::� ��i�' AS REQUIRED PUBLIC WORKS DEPARTMENT AT THE DEVELOPER'S EXPENSE. THE PUBLIC 3. SEE COE STD DWG N0. 610 AND DETAIL A/C4.1 FOR TYPICAL TRENCH � � <br /> . ..�. <br /> ._:... . � <br /> � �'��ii��i �°� '::� : :.�;..:�:.:..:,.. �• � : .<>.,:.... "�.°.. ��i����, >� Q <br /> z�.:.... i�i ......... ... <br /> "%�ii ao ao 00 �oo� oo �-oo ` o0 00� `oo' oa oo° o ��\i, � � ��� WORKS DEPARTMENT SHALL BE GIVEN AT LEAST 5 BUSINESS DAYS SECTION. � ° . <br /> . �i�°�'�O ° °°�' °°� °°&' °°� °� °°g° °°� °°�'°� �\\i z � ���� �j��� NOTICE FOR EACH CONNECTION. THE PUBLIC WORKS DEPARTMENT SHALL <br /> ����%�� � o ���/� /`��/`���`�������������� � I.D.+18" MIN. THEREAFfER DETERMINE THE DATE AND TIME AT WHICH THE CONNECTION 4. SEE COE STD DWG N0. 611 FOR PIPE BEDDING IN TRENCHES. " z <br /> 6"4� HOLE � o I.D.+24" MAX. SHALL BE MADE. _ <br /> SECTION A-A °° 3. ALL WORK AND MATERIALS MUST CONFORM TO CITY OF EVERETT 5. SEE COE STD DWG N0. 615 FOR TYPICAL TRENCH COMPACTION VALUES. ��G C. y� <br /> _ STANDARDS. 6. SEE COE STD DWG N0. 604 FOR SEWER CLEAN-OUT �°F wAs�j� <br /> SECTION TYPICAL TRENCH, ��, <br /> � SANITARY SEWER FORCE MAIN VALVE A PLASTIC SEWER PIPE 4. A PRE-CONSTRUCTION MEETING SHALL BE HELD WITH THE CITY PRIOR <br /> TO THE START OF CONSTRUCTION. THE CITY OF EVERETT PUBLIC WORKS <br /> C4.0 C4.1 NOT TO SCALE C4.0 C4.1 NOT TO SCALE CONSTRUCTtON DIVISiON MUST BE NOTIFIED AT LEAST 24 HOURS PRIOR �"t' 39428 w� <br /> , TO COMMENCEMENT OF CONSTRUCTION. °��s`��cISTE��°���'�' <br /> SI�NAL E� <br /> , 05FT WETWELL 5. THE DEVELOPER OF THE DEVELOPER�s au-rHOR�zEo� acEN-r sHa�� NOT��,r MATERIAL SPECIFICATIONS �WATER�: �j�/� <br /> THE PUBLIC WORKS DEPARTMENT OF A PERSON WHO CAN BE -r- <br /> BOLT ON INVERT ___'�*** CONTACTED REGARDING PROBLEMS DURING CONSTRUCTION ON A 24 „ g _ <br /> HOUR BASIS. 1. ACCEPTABLE PIPE MATERIALS (MAINS - LARGER THAN 2 PIPE): � <br /> - DUCTILE IRON PIPE, CEMENT LINED, STANDARD THICKNESS CLASS 52 � � <br /> � - 6. MAINTAIN A MINIMUM OF 10 FEET HORIZONTAL AND 18 INCHES VERTICAL CONFORMING TO ANSI/AWWA A2.51/C-151. � � <br /> SEPARATION BETINEEN POTABLE AND NON=POTABLE CONVEYANCE � .o g <br /> I f o I SYSTEMS. 2. JOINTS AND FITfINGS: � N r? <br /> RUBBER GASKET PIPE JOINTS SHAL� BE PUSH-ON-JOINT o -�- <br /> P O W E R & C O N T R O L 7. ALL CITY OF EVEREfT VALVES SHALL BE OPERATED BY PUBLIC WORKS MON OR MECMANICAL JOINT M J.) CONFORMING TO ,; � � <br /> CABLE OUTLET, �12" � - DISCHARGE� DEPARTMENT PERSONNEL ONLY. ALL VALVES, NEW AND EXISTING, SHALL A N S I ) A 2 . 1 - ( � � � <br /> _ FLANGE, 3 BE ACCESSIBLE AT ALL TIMES. /AWWA 1 1 /C 111. FLANGED JOINTS SHALL CONFORM TO ^ W � <br /> � PUMP, SUB ERSIBLE 3" ANSI/AWWA A21.15/C-115. THRUST RESTRAINTS ON ALL MECHANICAL . <br /> SEG.A15.20 �GRUNDFOS AND RESTRAINED JOINTS SHA�L BE MEGA-LUG OR APPROVED EQUAL. <br /> �� �F � <br /> 3. BURIED GATE VALVES SHALL BE IRON BODY, BRONZE MOUNTED, ,� - <br /> RESILIENT SEAL, NON-RISING STEM SUITABLE FOR THE TYPE AND CLASS - <br /> OF PIPE BEING INSTALLED. OPERATING STEMS SHALL BE EQUIPPED WITH . <br /> TOP VIEW DETAIL STANDARD 2 INCH OPERATION NUT AND "0" RING STEM SEALS. VALVES <br /> MUST BE OF THE TYPE TO NAVE TWO "0" RING STEM SEALS IN THE � <br /> STUFFING BOX TO FACILITATE SEAL REPLACEMENT WITH VALVE � <br /> ALUMINUM ACCESS UPPER GUIDE BRACKEf DISMANTLING. <br /> HATCH WITH LOCK <br /> , AND HANDLE, SAFETY GRATES 1-1/2" GUIDE RAILS, S.S. 4. VALVE BOXES: SEE COE STD DWG N0. 504. <br /> FLOAT BRACKET S.S. � � <br /> ACCESSIBLE FROM REINFORCED ALUMINUM 5. SEE COE STD DWG N0. 5026 FOR ACCEPTABLE SERVICE PIPE MATERIALS <br /> � HATCH OPENING DIAMOND PLATE COVER <br /> � (2 INCHES OR SMALLER) AND FITTINGS, � <br /> 3 IYP. - <br /> ELEV. JQTOP OF WETWELL ELEV. FINISHED GROUN 6. PIPE BEDDING SHALL CONFORM TO EVERETT WASHED COURSE SAND N0. <br /> c.i 2 AS SHOWN IN SECTION 3-20.3 OF COE DESIGN AND CONSTRUCTION <br /> � `- I I Ii=, ,I � �- STANDARDS AND SPECIFICATIONS MANUAL (2012). <br /> � �_ <br /> � <br /> POWER & CONTROL 7. TRENCH BACKFILL SHALL CONFORM TO WSDOT SECTION 9-03.14 GRAVEL <br /> W CABLE OUTLET, 012" <br /> � ELEV. DISCHARGE BORROW. <br /> � . <br /> " 8. CONCRETE THRUST BLOCKING: SEE WSDOT STANDARD PLAN B-90.40-00. � � <br /> � FLOATS ANCHOR . <br /> i ENVIRONBOOT (1 QF 3) 9. POST INDICATOR VALVE SHALL COMPLY WITH AWWA STANDARDS, SHALL -J =� <br /> �' LEVEL SENSOR PIPE SUPPORT 'Q <br /> � HAVE TAMPER SWITCH, SHALL BE UL/FM APPROVED, AND SHALL HAVE V <br /> � VALVE VAULT DRAIN LOCKABLE HANDLE, HEAVY PLEXIGLAS WINDOW WITH VALVE POSITION � ,rj � <br /> � REINFORCED W/ CHECK VALVE, 2" PVC INDICATOR READING OPEN OR CLOSED. Y Q <br /> �� FIBERGLASS WETWELL** <br /> � PI�PE BRACE, S.S, 10. FIRE DEPARTMENT CONNECTION (FDC): U V � <br /> � 3 PIPE, D.L 10.1. CAST BRASS BODY MATCHING WALL ESCUTCHEON LETfERED "AUTO J 0 Z <br /> � � „ CHAIN/CABLE ASSEMB�Y S.S. SPKR" WITH A CHROMIUM PLATED FINISH. (n Q <br /> W E EV. INVERT PUMP, SUBM RSIBLE 3" 10.2. CONNECTION SHALL HAVE TWO INLETS WITH INDIVIDUAL t-- O � <br /> � � SELF-CLOSING CLAPPERS, �? <br /> , Y EG.A15.20 GRUNDFOS CAPS WITH DRIP DRAINS AND CHAINS. � w <br /> ` ELEV.QHI ALARM �1 OF 2) 10.3. FEMALE INLETS: TWO, 2-1/2-INCH DIAMETER AMERICAN NATIONAL V � <br /> . � FIRE HOSE CONNECTION SCREW THREADS PER NFPA 1963. �y � <br /> °- ELEV.Q PUMP2 ON PUMP POWER CORDS 10.4. PROVIDE BRASS PLATE FOR MOUNTING ON RISER PIPE MARKED Y � <br /> �' ELE.11. PUMP1 ON "AUTO SPRKR & STAND PIPE" AND MARKED WITH NAME OF BUILDING Z <br /> � W _ <br /> �� ELEV. OFF n SERVED. � <br /> � 3 QUICK DISCONNECT BASE ELBOW 10.5. CROKER, TWO WAY CLAPPER INLET - 6000 SERIES FLUSH MOUNTED � <br /> m ELEV. ALARM OFF FDC OR EQUIVALENT. � _J � <br /> � <br /> � <br /> ,L � � <br /> � ELEV.� BOTTOM OF WETWEL o HOPPER BOTfOM <br /> > � J <br /> � <br /> «� BASE* <br /> 0 <br /> o � <br /> ' / � , <br /> � <br /> o , <br /> � " SECTiON A-A � <br /> � � <br /> � � <br /> - G.P.M. T.D.H. H.P. R.P.M. PHASE VOLTS A B C D EE EVATIO FS G H ' J / AS SHOWN - <br /> sca,�e <br /> � °ES. LKJ SHEET N0. <br /> � 100 29.14 0.00 3.57 3.82 4.33 4.84 5.10 5.10 16.5± 14.0± 8.20 K110W WI11t�s below. PAH <br /> DR. <br /> � <br /> Ca�l before you dig. �"� HNK C4'. � <br /> � 2 PUMPTECH MODEL 421 PUMP STATION <br /> F.B. <br /> O <br /> N C4.0 C4.1 NOT TO SCALE ����� <br /> � NOTE: E-------� � - �EETS <br /> � �� �� �� DATE MAY 9, 2017 <br /> � EAR LY S ITE G RAD I N G P E R M IT S ET ADJUSTDS�CALES�A CORDINGLY. NDE 212016.008 <br /> O � <br />