My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
824 W CASINO RD BLDG D 2019-03-22
>
Address Records
>
W CASINO RD
>
824
>
BLDG D
>
824 W CASINO RD BLDG D 2019-03-22
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/22/2019 7:36:09 AM
Creation date
12/27/2018 3:10:30 PM
Metadata
Fields
Template:
Address Document
Street Name
W CASINO RD
Street Number
824
Tenant Name
BLDG D
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
58
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Simple Heating System Size: Washington State <br /> This heating system sizing calculator is based on the Prescriptive Requirements of the 2015 Washington State Energy Code(WSEC)and ACCA Manuals <br /> J and S.This calculator will calculate heating loads only.ACCA procedures for sizing cooling systems should be used to determine cooling loads. <br /> Please fill out all of the green drop-downs and boxes that are applicable to your project.As you make selections in the drop-downs for each section,some <br /> values will be calculated for you.If you do not see the selection you need in the drop-down options,please call the WSU Energy Extension Program at <br /> (360)956-2042 for assistance. <br /> Project information Contact information <br /> Avaire Apartments Renovation-Laundry Conversion Casino Westmont Affordable Housing <br /> 824 Casino Rd. Corey Baldwin <br /> Everett WA 98204 _ 42S-454-8205 Ext 238 <br /> Heating System Type: O All Other Systems 0 Heat Pump <br /> To see detailed instructions for each section,place your cursor on the word Instructions" <br /> Design Temperature <br /> Instructions <br /> Everett x Design Temperature Difference(AT) 47 <br /> AT=Indoor(70 degrees)-Outdoor Design Temp <br /> Area of Building <br /> Conditioned Floor Area <br /> Instructions Conditioned Floor Area(sq ft) I 720 I <br /> Average Ceiling Height Conditioned Volume <br /> Instructions Average Ceiling Height(ft) <br /> I. 7-8I 5,580 <br /> Glazing and Doors U-Factor X Area = UA <br /> instructions <br /> 11-025 0.250 I 60 + 15.00 <br /> Skylights U-Factor X Area = UA <br /> Instructions <br /> 0.50 0 .. <br /> Insulation <br /> Attic U-Factor X Area = UA <br /> Instructions <br /> R-38 Advanced 0.026 I 720' I 18.72 <br /> Single Rafter or Joist Vaulted Ceilings U-Factor X Area UA <br /> Instructions <br /> No Vaulted Ceilings in this project — 6 <br /> Above Grade Walls(see_Figure 1) U-Factor X Area UA <br /> Instructions " -c-- _ <br /> R 21 Intermediate0.056 I 868 I 48.61 <br /> Floors <br /> U-Factor X Area UA <br /> Instructions - unconditioned -_. _t.. — I_, 0 I <br /> No floors above , <br /> Imati <br /> Below Grade Walls(see Figure 1) U-Factor X Area UA <br /> Instructions ._ ---^--•-- -•w �: <br /> No Below Gude Wails in this project• 0,028 -. <br /> Slab Below Grade(see Froure n F-Factor X Length UA <br /> Instructions �� <br /> ��No slab&�rnv Grade n this prrgect 0.303 112. I 33.94 <br /> Slab on Grade(see tinu,e n F-Factor X Len.111 UA <br /> Instructions <br /> R-10 Perimeter 0.540 112 60.48 <br /> 'a+n?»tr.raz• �•A•m:..z rm+ rs ._... „4, <br /> Location of Ducts <br /> Instructions • - Duct Leakage Coefficient <br /> NO Ducts - <br /> 1 1.00 <br /> Sum of UA 176.74 <br /> Envelope Heat Load 8,307 Btu/Hour <br /> Figure 1. Sum ofIJAXAT <br /> �_ Air Leakage Heat Load 2,832 Btu/Hour <br /> Volume 0_6XATX.018 <br /> Above Grade Building Design Heat Load 11,139 Btu/Hour <br /> - ALeakage+Envelope Hear Loss <br /> Building and Duct Heat Load <br /> -`�'��~� <br /> � VY - 11,139 Btu/Hour <br /> Duds in unconditioned space:Sum of Bud3ng Heat Loss X 1.10 <br /> Duds in candfroned space:Sum of B ichg Heat Loss X 1 <br /> Maximum Heat Equipment Output 15,595 Btu/Hour <br /> Bolding and Dud Heat Lass X 1.40 for Fortzd Air Furnace <br /> Brddg and Duct Heat Loss X1.25 for Heat Pump <br /> (07/01/13) <br />
The URL can be used to link to this page
Your browser does not support the video tag.