Simple Heating System Size: Washington State <br /> This heating system sizing calculator is based on the Prescriptive Requirements of the 2015 Washington State Energy Code(WSEC)and ACCA Manuals <br /> J and S.This calculator will calculate heating loads only.ACCA procedures for sizing cooling systems should be used to determine cooling loads. <br /> Please fill out all of the green drop-downs and boxes that are applicable to your project.As you make selections in the drop-downs for each section,some <br /> values will be calculated for you. If you do not see the selection you need in the drop-down options,please call the WSU Energy Extension Program at <br /> (360)956-2042 for assistance. <br /> Project Information Contact information <br /> Avaire Apartments Renovation-Laundry Conversion Casino Westmont Affordable Housing <br /> 824 Casino Rd. Corey Baldwin <br /> Everett WA 98204 . ' 425-454-8205 Ext.238 ' <br /> Heating System Type: O All Other systems C) heat Pump <br /> To see detailed instructions for each section,place your cursor on the word instructions'. <br /> Design Temperature <br /> Instructionst- - - - - <br /> Everett x Design Temperature Difference(AD 47 <br /> .....,: �,...�_ _ _. .` AT=Indoor(70 degrees)-Outdoor Design Temp <br /> Area of Building <br /> Conditioned Floor Area <br /> Instructions Conditioned Floor Area(sq ft) I 720 I <br /> Average Ceiling Height Conditioned Volume <br /> Instructions Average Ceiling Height(ft) 7.81 5,580 <br /> Glazing and Doors U-Factor X Area = UA <br /> instructions '. <br /> 0.250 60 15.00 <br /> Skylights `� U-Factor X Area = UA <br /> Instructions <br /> 0.50 U — <br /> Insulation <br /> Attic U-Factor X Area = UA <br /> Instructions <br /> R 38 Advanced . : 0.026 720 18.72 <br /> Single Rafter or Joist Vaulted Ceilings U-Factor X Area UA <br /> Instructions <br /> No Vaulted Ceilings in this project .r; — 0 <br /> Above Grade Walls(see Figure 1) U-Factor X Area UA <br /> Instructions ------_--------.- <br /> R-21 Intermediate E 0.056 I 868 I 48.61 <br /> Floors U-Factor X Area UA <br /> InstructionsI. <br /> No Floors above unoondrtia-ml spaces. yr l:_ — <br /> Below Grade Walls(seeFrgure 1) U-Factor X Area UA <br /> Instructions <br /> 0.028 1 <br /> No Below Grade Walls in this project <br /> Slab Below Grade/see Rowell F-Factor X Length UA <br /> Instructions 0.303 <br /> I 112 I 33-94 <br /> Slab on Grade(see Rya/ra v F-Factor X Len•th UA <br /> Instructions - •�'°" -- /,,� <br /> R to Fenmeter e' 0.540 112 60.48 <br /> Location of Ducts <br /> Instructions ----- ---- _.__... <br /> 0.„,,_„„.„,„..,,,,................„______14 <br /> Duct Leakage Coefficient <br /> No Dugs <br /> 1.00 <br /> Sum of UA 176.74 <br /> Envelope Heat Load 8,307 Btu/Hour <br /> Figure 1. SUM of UAXAT <br /> Air Leakage Heat Load 2,832 Btu 1 Hour <br /> - Valo-neX O.6XATX.018 <br /> Above Grade Building Design Heat Load 11,139 Btu/Hour <br /> Air Leakage+Envelope Heat Loss <br /> Building and Duct Heat Load 11,139 Btu/Hour <br /> Ducts in uncoradrtionedspace:Sum of Budding Heat Loss X 1.10 <br /> Drat in conditioned space:Sum of Buidng Heat Loss X 1 <br /> Maximum Heat Equipment Output 15,595 Btu/Hour <br /> Buidrg and Duct Heat Loss X 1.40 for Forced Air Furnace <br /> Bui6ng and Duct Heat Loss X 1.25 for Neat pump <br /> (07/01/13) <br />