My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
14 E CASINO RD SHERWOOD COMMUNITY SERVICES 2018-01-01 MF Import
>
Address Records
>
E CASINO RD
>
14
>
SHERWOOD COMMUNITY SERVICES
>
14 E CASINO RD SHERWOOD COMMUNITY SERVICES 2018-01-01 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/4/2019 8:45:36 AM
Creation date
1/4/2019 8:45:36 AM
Metadata
Fields
Template:
Address Document
Street Name
E CASINO RD
Street Number
14
Tenant Name
SHERWOOD COMMUNITY SERVICES
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
51
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
,� <br /> � c� <br /> Building C chunged occupnncy from B to E-3 on May 5`�, 1999. Although <br /> the size of the overall building was 10,265 square feet, the school portion of <br /> the building was only 5,653 square feet. At that time, the building wns not <br /> required to have a sprinkler system installed as the cl�unge of occupancy w�u <br /> not greater than 6J00 square feet, nnd that no additional area wns ;idded to <br /> the building. <br /> The current proposal for Building D is to convert the remaining 5alance of <br /> 4,612 squarc feet into E-3 Duycare usage. The entire I0,265 square foot <br /> building would then be un E-3 occupnncy, and over tl�e 6,000 square foot <br /> threshold. To proceed with this change of use, there are two options: <br /> a) Install an approved automatic sprinkler system in both portions (C <br /> and D)of the building per Ordnance 1902-92,or <br /> b) Create an assumed property line between the two buildiugs and <br /> follow the fire-resistive requirements of walls and openings based <br /> on distanced to property lines as prescrit+ed in Section 503.3 and <br /> Tnble 5-A. Please note that the exception to Section 503.3 would <br /> not apply in this case. <br /> 2. Wire glazing should only be used in corridor relites. Relites in non-reted <br /> walls should use safety glnzing. Section 2406.4.3, Exception 2 <br /> 3. Doors #9, 1 l, 14 & ?0 should have su� unobstructed floor space a minimum <br /> of 18 inches beyond the strike jamb and extend at lenst 60 inches <br /> perpendicular to the doonvay from the pull-side approach. Section 1106.10.3 <br /> Prepare a response letter showing where each item in this correction letter is addressed <br /> on the plan set. <br /> Upon submittal of the drawings, your application will be given priority and plan review <br /> will recommence. <br /> All required submittals sliall be of sufticient detail and contain sufficient infortnation to <br /> ensure that tha proposed structure will be conswcted in compliance with aIl adopted <br /> codes. <br /> Sincerely, <br /> � <br /> �� � <br /> / �l <br /> �—� <br /> T6tfy Lee <br /> Associate Engincer <br /> OFDIPLS[AATIVLEEPumtawl LIl'f1.E RFO X'l1IXIL110USE <br />
The URL can be used to link to this page
Your browser does not support the video tag.